The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone

被引:35
|
作者
Silva, MJ
Hollstien, SB
Fayazi, AH
Adler, P
Gelberman, RH
Boyer, MI
机构
[1] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] Penn State Univ, Hershey Med Ctr, Dept Orthoped, Hershey, PA 17033 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 1998年 / 80A卷 / 10期
关键词
D O I
10.2106/00004623-199810000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined the effects of multiple-strand suture techniques on the tensile properties of flexor digitorum profundus tendon-to-bone repairs in a human cadaver finger model. Forty-four fingers were obtained from the cadavera of fifteen donors who had been an average of seventy-four years old (range, fifty-four to eighty-nine years old) at the time of death. Four or eight-strand proximal grasping sutures were secured to the distal phalanx of each finger with use of either a suture anchor or a dorsally placed button. There,were four subgroups of eleven fingers each. We found that repairs performed with use of a dorsally placed button had greater yield force, ultimate force, and rigidity than those performed,vith use of an anchor and that repairs performed with eight strands had greater ultimate force than those performed with four strands. These differences were significant (p < 0.05). We could detect no differences among the four types of repairs with regard to the amount of relative tendon-bone elongation at twenty newtons of force. The repairs performed with eight strands and a dorsally placed button had an average yield force (and 95 per cent confidence interval) of 50.0 +/- 14.1 newtons, an average ultimate force of 68.5 +/- 14.6 newtons, an average rigidity of 744 +/- 327 newton/(millimeter/millimeter), and an average tendon-bone elongation of 3.4 +/- 0.7 millimeters at twenty newtons of force. Multiple-comparison testing showed that the eight-strand repairs performed with a dorsally placed button had greater ultimate force than the other three types of repairs as well as greater yield force and rigidity than the four and eight-strand repairs performed with a suture anchor.
引用
收藏
页码:1507 / 1514
页数:8
相关论文
共 50 条
  • [31] The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: A biomechanical study in dogs
    Winters, SC
    Gelberman, RH
    Woo, SLY
    Chan, SS
    Grewal, R
    Seiler, JG
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (01): : 97 - 104
  • [32] Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: An in vitro study
    Hannafin, JA
    Arnoczky, SP
    Hoonjan, A
    Torzilli, PA
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) : 907 - 914
  • [33] The Accommodation of Bone Anchors Within the Distal Phalanx for Repair of Flexor Digitorum Profundus Avulsions
    Bond, Sarah
    Rust, Philippa
    Boland, Maria
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (11): : 986.e1 - 986.e6
  • [34] Effect of stress deprivation and cyclic tensile loading on the material and morphologic properties of canine flexor digitorum profundus tendon: An in vitro study
    LCOR, College of Veterinary Medicine, Michigan State University, East Lansing, MI 48824, United States
    J. ORTHOP. RES., 6 (907-914):
  • [35] Ultrasonographic assessment in vivo of the excursion and tension of flexor digitorum profundus tendon on different rehabilitation protocols after tendon repair
    Wang, Jun
    Qian, Lei
    Liu, Zhenfeng
    Wang, Xinhao
    Li-Tsang, Cecilia
    Li, Jianan
    Rui, Yongjun
    JOURNAL OF HAND THERAPY, 2022, 35 (04) : 516 - 522
  • [36] Interposition Tendon Graft and Tension in the Repair of Closed Rupture of the Flexor Digitorum Profundus in Zone III or IV
    Kim, Young Jun
    Baek, Jong Hun
    Park, Jin Sung
    Lee, Jae Hoon
    ANNALS OF PLASTIC SURGERY, 2018, 80 (03) : 238 - 241
  • [37] Repair Technique Using a Combination of Suture Anchor and Miniscrew in Flexor Digitorum Profundus Bony Avulsion Fracture with Bone Fragment in Zone 1
    Nho, Jae-Hwi
    Lee, Sang-Woo
    Nam, Mi-Ae
    Kim, Byung-Sung
    Jung, Ki Jin
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2018, 23 (03): : 430 - 436
  • [38] The effect of flexor digitorum profundus tendon shortening on jersey finger surgical repair: a cadaveric biomechanical study
    Gillig, J. D.
    Smith, M. D.
    Hutton, W. C.
    Jarrett, C. D.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (07) : 729 - 734
  • [39] A Meta-Analysis of Biomechanical Studies for Suture Button Pullout Versus Suture Anchor Repair of Flexor Digitorum Profundus Avulsions
    Imbergamo, Casey M.
    Sequeira, Sean B.
    Miles, Megan R.
    Means Jr, Kenneth R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (04): : 671 - 678
  • [40] Biomechanical Analysis of a New Eight-Strand Suture for Flexor Tendon Repair
    Moriya, Koji
    Maki, Yutaka
    Koda, Hisao
    Tsubokawa, Naoto
    INDIAN JOURNAL OF PLASTIC SURGERY, 2022, 55 (03) : 294 - 298