Hygienic aspects of ground-coupled air systems

被引:2
|
作者
Fluckiger, B [1 ]
Monn, C
Luthy, P
Wanner, HU
机构
[1] ETH Zentrum, Inst Hyg & Appl Physiol, Hyg Sect, CH-8092 Zurich, Switzerland
[2] ETH Zentrum, Inst Microbiol, CH-8092 Zurich, Switzerland
关键词
indoor air quality; microbial contamination; ground-coupled air systems; ventilation;
D O I
10.1111/j.1600-0668.1998.t01-1-00007.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Numerous ground-coupled air systems have been constructed in combination with heat recovery units in mechanically ventilated buildings in Switzerland. The objective of this study was to investigate the microbial content within these ventilation systems and to monitor the quality of the air supply. The concentrations and the types of microorganisms in the outdoor air, in the air of the pipes and in the supply air of twelve ground-coupled air systems were determined. In addition, three buildings were examined four times a year to cover seasonal changes. In general, the concentrations of fungal spores and bacteria in the air at the end of the underground pipes were lower than in the outdoor air, but great differences were observed between ventilation systems of large buildings and one-family houses. Occasionally, an increase in the concentration of Penicillium, Aspergillus or Actinomycetes was noted within a piping system. The concentrations in the supply air behind the filters were always low. Based on these investigations, the operation of ground-coupled air systems can be recommended as long as regular controls are undertaken and cleaning facilities are available.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 50 条
  • [31] A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling
    Esen, Hikmet
    Inalli, Mustafa
    Esen, Mehmet
    BUILDING AND ENVIRONMENT, 2007, 42 (05) : 1955 - 1965
  • [32] A highly efficient solution for thermal compensation of ground-coupled heat pump systems and waste heat recovery of kitchen exhaust air
    Wang, Kuan
    Li, Nianping
    Peng, Jinqing
    Wang, Xiang
    Wang, Chunlei
    Wang, Meng
    ENERGY AND BUILDINGS, 2017, 138 : 499 - 513
  • [33] Ground-coupled air waves and diffracted infrasound from the Arequipa earthquake of June 23, 2001
    Le Pichon, A.
    Guilbert, J.
    Vega, A.
    Garcés, M.
    Brachet, N.
    Geophysical Research Letters, 2002, 29 (18) : 33 - 1
  • [34] Optimization and Analysis of a Vertical Ground-Coupled Heat Pump
    Kord, Ali Siavoshi
    Jazayeri, Seyed Ali
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (01): : 33 - 37
  • [35] Effect of size on ground-coupled heat pump performance
    Alalaimi, M.
    Lorente, S.
    Anderson, R.
    Bejan, A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 : 115 - 121
  • [36] THE USE OF GROUND-COUPLED TANKS IN SOLAR-ASSISTED HEAT-PUMP SYSTEMS
    METZ, PD
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04): : 366 - 372
  • [37] Computer simulation of ground-coupled liquid desiccant air conditioner for sub-tropical regions
    Lee, C. K.
    Lam, H. N.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (12) : 2365 - 2374
  • [38] Study on Thermal Resistance of Coaxial Tube Boreholes in Ground-Coupled Heat Pump Systems
    Fang, Liang
    Diao, Nairen
    Shao, Zhukun
    Wang, Zuotao
    Fang, Zhaohong
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3735 - 3742
  • [39] Water loop design for ground-coupled heat pumps
    Kavanaugh, S
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1996, 38 (05): : 43 - 47
  • [40] Numerical simulation of a horizontal ground-coupled heat pump
    Javaherdeh, K.
    Karimi, H.
    International Journal of Energy and Environmental Engineering, 2010, 1 (01) : 27 - 35