Numerous ground-coupled air systems have been constructed in combination with heat recovery units in mechanically ventilated buildings in Switzerland. The objective of this study was to investigate the microbial content within these ventilation systems and to monitor the quality of the air supply. The concentrations and the types of microorganisms in the outdoor air, in the air of the pipes and in the supply air of twelve ground-coupled air systems were determined. In addition, three buildings were examined four times a year to cover seasonal changes. In general, the concentrations of fungal spores and bacteria in the air at the end of the underground pipes were lower than in the outdoor air, but great differences were observed between ventilation systems of large buildings and one-family houses. Occasionally, an increase in the concentration of Penicillium, Aspergillus or Actinomycetes was noted within a piping system. The concentrations in the supply air behind the filters were always low. Based on these investigations, the operation of ground-coupled air systems can be recommended as long as regular controls are undertaken and cleaning facilities are available.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 50 条
  • [1] Air-Launched and Ground-Coupled GPR Data
    Diamanti, Nectaria
    Annan, A. Peter
    2017 11TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2017, : 1694 - 1698
  • [2] The modeling of ground-coupled heat pump systems
    Qu, Yun-Xia
    Li, An-Gui
    Zhang, Lin-Hua
    Fang, Zhao-Hong
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2007, 39 (02): : 235 - 239
  • [3] Study on hybrid ground-coupled heat pump systems
    Man Yi
    Yang Hongxing
    Fang Zhaohong
    ENERGY AND BUILDINGS, 2008, 40 (11) : 2028 - 2036
  • [4] Feasibility of using ground-coupled condensers in A/C systems
    Said, Syed Ahmad M.
    Habib, Mohamed A.
    Mokheimer, Esmail M. A.
    El-Sharqawi, Mostafa H.
    GEOTHERMICS, 2010, 39 (02) : 201 - 204
  • [5] GROUND-COUPLED AIR WAVES FROM GREAT ALASKAN EARTHQUAKE
    DONN, WL
    POSMENTIER, ES
    JOURNAL OF GEOPHYSICAL RESEARCH, 1964, 69 (24): : 5357 - +
  • [6] Hygienic aspects for heating and air conditioning systems
    Liese, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1935, 79 : 125 - 129
  • [7] Closed-loop ground-coupled heat pump systems
    Bernier, Michel A.
    ASHRAE JOURNAL, 2006, 48 (09) : 12 - +
  • [8] Investigation of the performance of ground-coupled heat exchanger technology for tempering air
    Gooroochurn, Mahendra
    Mungur, Maheshsingh
    Shamachurn, Heman
    Surnam, Yashwansingh
    Mandarkhan, Fardeen
    Bhoodoo, Devin
    Journal of Energy Systems, 2022, 6 (02): : 309 - 321
  • [9] Experimental investigation of a ground-coupled desiccant assisted air conditioning system
    Speerforck, Arne
    Schmitz, Gerhard
    APPLIED ENERGY, 2016, 181 : 575 - 585
  • [10] A review for the applications and integrated approaches of ground-coupled heat pump systems
    Zhai, X. Q.
    Qu, M.
    Yu, X.
    Yang, Y.
    Wang, R. Z.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (06): : 3133 - 3140