Detection of Gliadin in Foods Using a Quartz Crystal Microbalance Biosensor That Incorporates Gold Nanoparticles

被引:54
|
作者
Chu, Pei-Tzu [1 ]
Lin, Chih-Sheng [2 ]
Chen, Wei-Jung [3 ]
Chen, Chih-Feng [4 ]
Wen, Hsiao-Wei [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Food Sci & Biotechnol, Taichung 402, Taiwan
[2] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu, Taiwan
[3] Natl Ilan Univ, Inst Biotechnol, Ilan, Taiwan
[4] Natl Chung Hsing Univ, Dept Anim Sci, Taichung 402, Taiwan
关键词
gliadin; quartz crystal microbalance immunosensor; gold nanoparticles; LINKED-IMMUNOSORBENT-ASSAY; EXERCISE-INDUCED ANAPHYLAXIS; CELIAC-DISEASE; EGG-YOLK; GLUTEN PROTEINS; WHEAT GLIADIN; ANTIBODY; ENZYME; SAMPLES; IMMUNOSENSOR;
D O I
10.1021/jf2047866
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
This work develops a label-free gliadin immunosensor that is based on changes in the frequency of a quartz crystal microbalance (QCM) chip. A higher sensitivity was obtained by applying 25 nm gold nanoparticles (AuNPs) to the surface of a bare QCM electrode. Subsequently, chicken anti-gliadin antibodies (IgY) were immobilized directly on the AuNP-modified surface by cross-linking amine groups in IgY with glutaraldehyde. Experimental results revealed that the change in frequency exhibited when 2 ppm gliadin was bound to the AuNP-modified electrode was 35 Hz (48%) greater than that of the bare gold electrode. The linear dynamic range in 60% ethanol was from 1 X 10(1) to 2 X 10(5) ppb gliadin, and the calculated limit of detection (LOD) was 8 ppb. The entire detection process was completed in 40 min and was highly repeatable. Additionally, the AuNP-modified QCM system generated results in the detection of gliadin in 10 commercial food products that were consistent with those obtained using an AOAC-approved gliadin kit. In conclusion, the QCM platform provides a potential alternative means of ensuring that people with wheat allergies and celiac patients have access to gliadin-free food.
引用
收藏
页码:6483 / 6492
页数:10
相关论文
共 50 条
  • [31] Pocketable Biosensor Based on Quartz-Crystal Microbalance and Its Application to DNA Detection
    Yoshimine, Hiroshi
    Sasaki, Kai
    Furusawa, Hiroyuki
    SENSORS, 2023, 23 (01)
  • [32] Signal amplification of a quartz crystal microbalance immunosensor by gold nanoparticles-polyethyleneimine for hepatitis B biomarker detection
    Zahra Saffari
    Reza Ahangari Cohan
    Mina Sepahi
    Mahdi Sadeqi
    Mehdi Khoobi
    Mojtaba Hamidi Fard
    Amir Ghavidel
    Fahimeh Bagheri Amiri
    Mohammad Reza Aghasadeghi
    Dariush Norouzian
    Scientific Reports, 13
  • [33] Signal amplification of a quartz crystal microbalance immunosensor by gold nanoparticles-polyethyleneimine for hepatitis B biomarker detection
    Saffari, Zahra
    Cohan, Reza Ahangari
    Sepahi, Mina
    Sadeqi, Mahdi
    Khoobi, Mehdi
    Fard, Mojtaba Hamidi
    Ghavidel, Amir
    Amiri, Fahimeh Bagheri
    Aghasadeghi, Mohammad Reza
    Norouzian, Dariush
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [34] Quartz crystal microbalance-based biosensor for the detection of α-thalassemia 1 (SEA deletion)
    Chomean, Sirinart
    Potipitak, Tiparat
    Promptmas, Chamras
    Ittarat, Wanida
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (09) : 1247 - 1254
  • [35] Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection
    Mannelli, I
    Minunni, M
    Tombelli, S
    Mascini, M
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 129 - 140
  • [36] Lubricity of gold nanocrystals on graphene measured using quartz crystal microbalance
    M. S. Lodge
    C. Tang
    B. T. Blue
    W. A. Hubbard
    A. Martini
    B. D. Dawson
    M. Ishigami
    Scientific Reports, 6
  • [37] Improving the sensitivity of a quartz crystal microbalance for biosensing by using porous gold
    van Noort, D
    Rani, R
    Mandenius, CF
    MIKROCHIMICA ACTA, 2001, 136 (1-2) : 49 - 53
  • [38] STUDIES OF THE SURFACE ELECTROCHEMISTRY OF GOLD USING THE QUARTZ CRYSTAL MICROBALANCE TECHNIQUE
    BRUCKENSTEIN, S
    SHAY, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 132 - ANYL
  • [39] Improving the Sensitivity of a Quartz Crystal Microbalance for Biosensing by Using Porous Gold
    Danny van Noort
    Raffaele Rani
    Carl-Fredrik Mandenius
    Microchimica Acta, 2001, 136 : 49 - 53
  • [40] POLYSTYRENE NANOPARTICLES BASED IMMUNOASSAY FOR THE DETECTION OF beta-GALACTOSIDASE USING QUARTZ CRYSTAL MICROBALANCE
    Choudhary, M. K.
    Singh, Prashant
    Singh, K. P.
    NANO LIFE, 2013, 3 (01)