Fabrication of Hexagonal CuCoO2 Modified Screen-Printed Carbon Electrode for the Selective Electrochemical Detection of Furaltadone

被引:8
|
作者
Mariappan, Kiruthika
Chen, Tse-Wei [1 ,2 ]
Chen, Shen-Ming
Tseng, Tien-Wen [1 ]
Bian, Yongzhong [3 ,4 ,5 ]
Sun, Ting-Ting [3 ]
Jiang, Jianzhuang [3 ,4 ,5 ]
Yu, Jaysan [6 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Res & Dev Ctr Smart Text Technol, Taipei 106, Taiwan
[3] Univ Sci & Technol Beijing, Sch Chem & Biol Engn, Dept Chem, Beijing Key Lab Sci & Applicat Funct Mol & Crysta, Beijing 100083, Peoples R China
[4] Univ Sci & Technol Beijing, Daxing Res Inst, Beijing 100083, Peoples R China
[5] Univ Sci & Technol Beijing, Beijing Adv Innovat Ctr Mat Genome Engn, Beijing 100083, Peoples R China
[6] Well Fore Special Wire Corp, 10 Tzu Chiang 7rd,Chung Li Ind Pk, Taoyuan, Taiwan
来源
基金
北京市自然科学基金;
关键词
Copper cobalt dioxide; Furaltadone; Electrochemical sensor; Screen-printed carbon electrode; Low detection limit; IN-HOUSE VALIDATION; LIQUID-CHROMATOGRAPHY; POULTRY MUSCLE; METABOLITES; COMPOSITE; DRUG; FURAZOLIDONE; NIFURSOL; RESIDUE; SENSOR;
D O I
10.20964/2022.06.21
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Furaltadone (FTD) is one of the veterinary drugs from the class of nitrofuran. Mostly the toxicity of the organic elements is very harmful, hence the toxic nature of FTD affects human health and the biosphere by inappropriate exuding of organic toxic elements. The as-prepared inorganic complex was characterized by field emission scanning electron microscope (FESEM), and X-ray diffraction (XRD) studies. Hydrothermally prepared copper-cobalt oxide (CuCoO2) is adorned on an activated screen-printed carbon electrode (ASPCE) for the detection of FTD by electrochemical methods which are Cyclic Voltammetry (CV), and Differential Pulse Voltammetry (DPV). The fabricated ASPCE/CuCoO2 electrode exhibits outstanding limits of detection (1.79 nM), high sensitivity (21.03 mu A mu M-1 cm(-1)), and broad linear range (0.1-316 mu M). The study of interference represents that metal ions and the nitro group have no impact on the FTD determination. Consequently, the ASPCE/CuCoO2 electrode reveals creditable for repeatability, reproducibility, and stability. Notably, this sensing platform also exhibits excellent performance in determining the FTD contents in Antibiotic samples, which suggests great potential for real-time applications.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Fabrication and electrochemical characterization of polydopamine redox polymer modified screen-printed carbon electrode for the detection of guanine
    Kanyong, Prosper
    Rawlinson, Sean
    Davis, James
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 : 528 - 534
  • [2] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. MATERIALS LETTERS, 2021, 304
  • [3] Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A
    Wan, H.
    Xie, X.
    Liu, H.
    Mahmud, S.
    [J]. Journal of Analytical Chemistry, 1600, 79 (11): : 1640 - 1648
  • [4] The fabrication of an MoS2QD-AuNP modified screen-printed electrode for the improved electrochemical detection of cefixime
    Sagar, Pinky
    Srivastava, Monika
    Prakash, Rajiv
    Srivastava, S. K.
    [J]. ANALYTICAL METHODS, 2020, 12 (23) : 3014 - 3024
  • [5] Electrochemical Detection of Arsenite Using a Silica Nanoparticles-Modified Screen-Printed Carbon Electrode
    Ismail, Suhainie
    Yusof, Nor Azah
    Abdullah, Jaafar
    Abd Rahman, Siti Fatimah
    [J]. MATERIALS, 2020, 13 (14)
  • [6] Polyaniline-chitosan modified on screen-printed carbon electrode for the electrochemical detection of perfluorooctanoic acid
    Suhaimi, Nur Farahin
    Baharin, Siti Nor Atika
    Jamion, Nurul Ain
    Zain, Zainiharyati Mohd
    Sambasevam, Kavirajaa Pandian
    [J]. MICROCHEMICAL JOURNAL, 2023, 188
  • [7] Poly(allylamine hydrochloride) modified screen-printed carbon electrode for sensitive and selective detection of NADH
    Rotariu, Lucian
    Istrate, Oana-Maria
    Bala, Camelia
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 : 491 - 497
  • [8] Modified screen-printed Electrode as Electrochemical Detector for Noscapine
    Aflatoonian, Mohammad Reza
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Behnaz
    Jafari, Maedeh
    Zhang, Kaiqiang
    Quyet Van Le
    Cha, Joo Hwan
    Shokouhimehr, Mohammadreza
    Peng, Wanxi
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8612 - 8621
  • [9] An electrochemical platform for the selective detection of azathioprine utilizing a screen-printed carbon electrode modified with manganese oxide/reduced graphene oxide
    Selvi, Subash Vetri
    Nataraj, Nandini
    Chen, Shen-Ming
    Prasannan, Adhimoorthy
    [J]. NEW JOURNAL OF CHEMISTRY, 2021, 45 (07) : 3640 - 3651
  • [10] Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode
    Shehata, M.
    Fekry, Amany M.
    Walcarius, Alain