An electrochemical platform for the selective detection of azathioprine utilizing a screen-printed carbon electrode modified with manganese oxide/reduced graphene oxide

被引:9
|
作者
Selvi, Subash Vetri [1 ]
Nataraj, Nandini [1 ]
Chen, Shen-Ming [1 ]
Prasannan, Adhimoorthy [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Electroanal & Bioelectrochem Lab, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Mat Sci & Engn, 43,Sect 4,Keelung Rd, Taipei 10607, Taiwan
关键词
NANOCOMPOSITE; NANOPARTICLES; SENSOR; REDUCTION; COMPOSITE; FABRICATION; CHITOSAN; RGO;
D O I
10.1039/d0nj05592a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The long-term use of the immunosuppressive drug, azathioprine (AZT), has been linked to a higher risk of certain cancers; hence, its effective detection is necessary. Recently, the use of transition metal/metal oxide-based materials has attracted intense interest in the field of electrochemistry in combination with carbon materials. Here, we fabricate and demonstrate the use of manganese oxide nanoparticle-decorated reduced graphene oxide modified screen-printed carbon electrodes (Mn2O3-rGO/SPCE) for the electrochemical determination of AZT. The structural, functional, and morphological characteristics of the composite material were evaluated using various analytical tools. The crystalline structure of the synthesized Mn2O3 nanoparticles is identified as orthorhombic with a crystallite size of 20 nm. The existence of sphere-shaped nanoparticles on the rGO sheets and the component elements are confirmed using field emission scanning electron microscopy (FESEM) and energy dispersive X-ray analysis (EDAX). The fabricated electrode (Mn2O3-rGO/SPCE) possesses high electrical conductance, as proved by electrochemical impedance spectroscopy, with an R-ct value of 90 omega. When compared with other electrodes, the Mn2O3-rGO/SPCE has a higher conductive behavior with a wide surface area and a boosted electron transfer, which in turn promotes the effective sensing of AZT. Differential pulsed voltammetry studies (DPV) revealed that the modified electrode possesses a lower limit of detection of about 4 nM, and a sensitivity of almost 7.7 mu A mu M-1 cm(-2), evaluated for a linear range from 0.009 mu M to 573.5 mu M. Repeatability and reproducibility studies exhibited a relative standard deviation (RSD) value of about 4.96% and 4.89%. Selectivity studies proved that the proposed sensor showed good selective detection in the presence of relevant interfering compounds. The fabricated Mn2O3-rGO modified SPCE would be an efficient sensor for real-time sensing of AZT because of its effective performance with human blood serum and urine samples.
引用
收藏
页码:3640 / 3651
页数:12
相关论文
共 50 条
  • [1] Nanosilver and Graphene Oxide Modified Screen-Printed Carbon Electrode for Electrochemical Detection of Bisphenol A
    Wan, H.
    Xie, X.
    Liu, H.
    Mahmud, S.
    [J]. Journal of Analytical Chemistry, 1600, 79 (11): : 1640 - 1648
  • [2] Electrocatalytic Oxidation of NADH on Graphene Oxide and Reduced Graphene Oxide Modified Screen-Printed Electrode
    Zhang, Lei
    Li, Yang
    Zhang, Li
    Li, Da-Wei
    Karpuzov, Dimitre
    Long, Yi-Tao
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (03): : 819 - 829
  • [3] Sensitive electrochemical sensor based on nickel/PDDA/reduced graphene oxide modified screen-printed carbon electrode for nitrite detection
    Paisanpisuttisin, Aunyarut
    Poonwattanapong, Praewpitcha
    Rakthabut, Punnada
    Ariyasantichai, Paranee
    Prasittichai, Chaiya
    Siriwatcharapiboon, Wilai
    [J]. RSC ADVANCES, 2022, 12 (45) : 29491 - 29502
  • [4] Development of an Electrochemical Sensor Based on Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for the Determination of Buprenorphine
    Fakhari, Ali Reza
    Sahragard, Ali
    Ahmar, Hamid
    [J]. ELECTROANALYSIS, 2014, 26 (11) : 2474 - 2483
  • [5] Graphene oxide modified screen-printed electrode for highly sensitive and selective electrochemical detection of ciprofloxacin residues in milk
    Pan, Ming
    Guo, Peipei
    Liu, Haifeng
    Lu, Jiawei
    Xie, Qiubo
    [J]. JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2021, 12 (01)
  • [6] Graphene oxide modified screen-printed electrode for highly sensitive and selective electrochemical detection of ciprofloxacin residues in milk
    Ming Pan
    Peipei Guo
    Haifeng Liu
    Jiawei Lu
    Qiubo Xie
    [J]. Journal of Analytical Science and Technology, 12
  • [7] Electrochemical Determination of Dextromethorphan on Reduced Graphene Oxide Modified Screen-Printed Electrode after Electromembrane Extraction
    Fakhari, Ali Reza
    Koruni, Mohammad Hossein
    Ahmar, Hamid
    Shahsavani, Abolfath
    Movahed, Siyavash Kazemi
    [J]. ELECTROANALYSIS, 2014, 26 (03) : 521 - 529
  • [8] Electrochemical Detection of Human Interleukin-15 using a Graphene Oxide-Modified Screen-Printed Carbon Electrode
    Norfun, Poachanee
    Suree, Nuttee
    Kungwan, Nawee
    Punyodom, Winita
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    [J]. ANALYTICAL LETTERS, 2017, 50 (07) : 1112 - 1125
  • [9] Application of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode
    Ping, Jianfeng
    Wang, Yixian
    Ying, Yibin
    Wu, Jian
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (07) : 3473 - 3479
  • [10] Tyrosinase/Chitosan/Reduced Graphene Oxide Modified Screen-Printed Carbon Electrode for Sensitive and Interference-Free Detection of Dopamine
    Liu, Cheng-You
    Chou, Yi-Chieh
    Tsai, Jui-Hsuan
    Huang, Tzu-Ming
    Chen, Jian-Zhang
    Yeh, Yi-Chun
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (04):