Linearisation control of AC permanent magnet synchronous motor servo system based on sensor technology

被引:1
|
作者
Liu, Yongqiu [1 ]
机构
[1] Guangdong Univ Sci & Technol, Dongguan 523083, Peoples R China
关键词
permanent magnet synchronous motor; PMSM; direct feedback linearisation; linearisation control; MATLAB simulation; sensor;
D O I
10.1504/IJBM.2020.105619
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
AC permanent magnet synchronous motor servo control system is a complex nonlinear, strong coupling and time-varying system. It has strong uncertainty and nonlinearity, and when the system is running, it also will be disturbed to varying degrees, so the conventional control strategy is difficult to meet the control requirements of high accuracy, high speed and high-performance servo system. This paper adopts a direct feedback linearisation control strategy based on sensor technology and uses, as the output of the system to realise the decoupling of the system. In addition, the grey prediction is added to overcome the shortcomings of direct feedback linearisation that is sensitive to parameters. Adjusting the uncertain factors block by grey prediction to adapt to the direct feedback linearisation rule and achieve the desired effect. MATLAB/Simulink is used to complete the simulation of servo control algorithm. The simulation results show that the direct feedback linearisation control is better than the conventional PID control, and the direct feedback linearisation control algorithm with grey prediction can improve the performance of the permanent magnet synchronous motor servo control system and can meet the basic requirements of the high-performance servo control system.
引用
收藏
页码:29 / 46
页数:18
相关论文
共 50 条
  • [41] AC permanent magnet synchronous motor system based on identification compensation technique
    Wang, Z
    Guo, QD
    ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 548 - 551
  • [42] Permanent Magnet Synchronous Motor Servo System Design and Algorithm Research
    Liu Luoren
    Luo Jinling
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 1465 - +
  • [43] Robust repetitive control for permanent-magnet linear synchronous motor servo system based on H∞ optimal control
    Sun, Yi-Biao
    Wang, Huan
    Yang, Jun-You
    Shenyang Gongye Daxue Xuebao/Journal of Shenyang University of Technology, 2012, 34 (03): : 241 - 246
  • [44] Permanent magnet synchronous motor servo system based on generalized predictive control with disturbance-rejection enhancement
    Wei Y.-F.
    Mao J.-L.
    Zhang C.-L.
    Yang J.
    Kongzhi yu Juece/Control and Decision, 2024, 39 (06): : 1967 - 1976
  • [45] Fast terminal sliding mode control of permanent magnet synchronous motor servo system with ESO
    Zhang Z.-X.
    Liu X.-D.
    Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2023, 40 (07): : 1233 - 1242
  • [46] SERVO DRIVE SYSTEM AND CONTROL CHARACTERISTICS OF SALIENT POLE PERMANENT-MAGNET SYNCHRONOUS MOTOR
    MORIMOTO, S
    HATANAKA, K
    TONG, Y
    TAKEDA, Y
    HIRASA, T
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (02) : 338 - 343
  • [47] Model Correction Control Strategy for Direct Drive Permanent Magnet Synchronous Motor Servo System
    Huang, Liangsong
    Qu, Daokui
    Xu, Fang
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 1467 - 1470
  • [48] Improved active disturbance rejection control for permanent magnet synchronous motor position servo system
    Qiu J.-Q.
    Liu R.-C.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2019, 23 (11): : 42 - 50
  • [49] Position Control of Permanent Magnet Synchronous Motor Speed Sensorless Servo System via Backstepping
    Shao, Mingling
    Yu, Haisheng
    Yu, Jinpeng
    Shan, Bingqiang
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4089 - 4094
  • [50] Integral Terminal Sliding Mode Control for Permanent Magnet Synchronous Motor Position Servo System
    Wang Junxiao
    Li Shihua
    Yang Jun
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 4408 - 4413