Dose rate constants for 125I, 103Pd, 192Ir and 169Yb brachytherapy sources:: an EGS4 Monte Carlo study

被引:33
|
作者
Mainegra, E [1 ]
Capote, R [1 ]
Lopez, E [1 ]
机构
[1] Ctr Estudios Aplicados Desarrollo Nucl, Dept Fis, Havana, Cuba
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 06期
关键词
D O I
10.1088/0031-9155/43/6/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An exhaustive revision of dosimetry data for Ir-192, I-125, Pd-103 and Yb-169 brachytherapy sources has been performed by means of the EGS4 simulation system. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. The absorbed dose rate per unit contained activity in a medium at 1 cm in water and air-kerma strength per unit contained activity for each seed model were calculated, allowing the dose rate constant (DRC) A to be estimated. The influence of the calibration procedure on source strength for low-energy brachytherapy seeds is discussed. Conversion factors for I-125 and Pd-103 seeds to obtain the dose rate in liquid water from the dose rate measured in a solid water phantom with a detector calibrated for dose to water were calculated. A theoretical estimate of the DRC for a Pd-103 model 200 seed equal to 0.669 +/- 0.002 cGy h(-1) U-1 is obtained. Comparison of obtained DRCs with measured and calculated published results shows agreement within 1.5% for Ir-192, Yb-169 and I-125 sources.
引用
收藏
页码:1557 / 1566
页数:10
相关论文
共 44 条
  • [41] Monte Carlo study of TG-43 dosimetry parameters of GammaMed Plus high dose rate 192Ir brachytherapy source using TOPAS
    Wu, Jianan
    Xie, Yaoqin
    Ding, Zhen
    Li, Feipeng
    Wang, Luhua
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 146 - 153
  • [42] Design and characterization of flattening filter for high dose rate 192Ir and 60Co Leipzig applicators used in skin cancer brachytherapy: A Monte Carlo study
    Ghobadi, Parvin
    Farhood, Bagher
    Ghorbani, Mahdi
    Mohseni, Mehran
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 123
  • [43] Experimental determination of radial dose function and anisotropy function of GammaMed Plus 192Ir high-dose-rate brachytherapy source in a bounded water phantom and its comparison with egs_brachy Monte Carlo simulation
    Buchapudi, Rekha Reddy
    Manickam, Ravikumar
    Chandaraj, Varatharaj
    [J]. JOURNAL OF MEDICAL PHYSICS, 2019, 44 (04) : 246 - 253
  • [44] Assessing Heterogeneity Effects on Points A, B, and Organs at Risk Doses in High-dose-Rate Brachytherapy for Cervical Cancer - A Comparison of 192Ir and 60Co Sources Using Monte Carlo N-Particle 5
    Sadeghi, Mohammad Hossein
    Sina, Sedigheh
    Meigooni, Ali Soleimani
    [J]. JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 294 - 303