Improving the standard of the standard for glass ionomers: An alternative to the compressive fracture strength test for consideration?

被引:25
|
作者
Dowling, Adam H. [1 ]
Fleming, Garry J. P. [1 ]
McGinley, Emma L. [1 ]
Addison, Owen [2 ]
机构
[1] Trinity Coll Dublin, Dublin Dent Univ Hosp, Div Oral Biosci, Mat Sci Unit, Dublin 2, Ireland
[2] Univ Birmingham, Biomat Unit, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
Glass ionomer restorative; ISO 9917-1: 2003; Compressive fracture strength; Three point flexure strength; Biaxial flexure strength; Validity; Reliability; CLINICALLY INDUCED VARIABILITY; PHOSPHATE DENTAL CEMENT; AXIAL FLEXURE STRENGTH; TENSILE-STRENGTH; BRITTLE MATERIALS; COMPOSITES; FAILURE; RATIO; FLUOROAPATITE; RESTORATIVES;
D O I
10.1016/j.jdent.2011.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three strength tests (compressive, three point flexure and biaxial) were performed on three glass ionomer (GI) restoratives to assess the most appropriate methodology in terms of validity and reliability. The influence of mixing induced variability on the data sets generated were eliminated by using encapsulated GIs. Methods: Specimen groups of 40 (eight batches of n = 5) cylinders (6.0 +/- 0.1 mm height, 4.0 +/- 0.1 mm diameter) for compressive fracture testing, bars (25.0 +/- 0.1 mm length, 2.0 +/- 0.1 mm height, 2.0 +/- 0.1 mm width) for three point flexure testing and discs (13.0 +/- 0.1 mm diameter, 1.0 +/- 0.1 mm thickness) for biaxial flexure testing were randomly prepared by an operator. The strength data sets for each GI restorative were pooled and one-way analyses of variance (ANOVAs) were conducted to compare between GI restoratives (p = 0.05). The coefficient of variation (CoV) values for each test were pooled and a one-way ANOVA was conducted to test for differences between the reliability of the three tests. Results: For the GI restoratives, the one-way ANOVA showed significant differences when tested in compression (p = 0.001) but not when tested in three point (p = 0.271) or biaxial (p = 0.134) flexure. The pooled CoV values showed no significant difference between the three strength tests (p = 0.632). Conclusions: The compressive fracture strength test specified for GIs in the International Organisation for Standardisation (ISO 9917-1: 2003) should be replaced and should no longer be advocated for the predictive performance modelling of GI restoratives. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:189 / 201
页数:13
相关论文
共 50 条
  • [31] Interfacial failures in a compressive shear strength test of glass/polymer laminates
    Rahul-Kumar, P
    Jagota, A
    Bennison, SJ
    Saigal, S
    [J]. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2000, 37 (48-50) : 7281 - 7305
  • [32] EFFECT OF SIC PARTICLES ON COMPRESSIVE STRENGTH AND FRACTURE FEATURES OF GLASS PHENOLIC COMPOSITES
    CHANDRA, DS
    RAO, RMVGK
    KISHORE
    [J]. SCRIPTA METALLURGICA ET MATERIALIA, 1991, 25 (07): : 1641 - 1646
  • [34] Comparative analysis of the strength characteristics of transparent glass sand and standard sand
    [J]. Kong, G. (gqkong1@163.com), 1600, Tongji University (17):
  • [35] A Review of Alternative Procedures to the Bond Ball Mill Standard Grindability Test
    Nikolic, Vladimir
    Garcia, Gloria G.
    Coello-Velazquez, Alfredo L.
    Menendez-Aguado, Juan M.
    Trumic, Milan
    Trumic, Maja S.
    [J]. METALS, 2021, 11 (07)
  • [36] Accurate Solutions of Stress Intensity Factors of Standard Fracture Test Specimens
    Saimoto, Akihide
    Motomura, Fumitaka
    Nisitani, Hironobu
    [J]. ADVANCES IN FRACTURE AND DAMAGE MECHANICS IX, 2011, 452-453 : 405 - +
  • [37] PLASTIC SURFACE-COATINGS - ALTERNATIVE TO STANDARD THIN SECTION COVER GLASS
    MOUSSA, MT
    [J]. MICROSCOPICA ACTA, 1978, 80 (04): : 331 - 333
  • [38] EFFECT OF STANDARD PENETRATION TEST CORRECTIONS ON THE ESTIMATION OF UNDRAINED SHEAR STRENGTH
    Tan, Jia Jun
    Ramli, Harris
    [J]. JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2023, 29 (06) : 501 - 515
  • [39] NON-STANDARD TEST METHOD FOR GLUE LINE SHEAR STRENGTH
    Li, Rongrong
    Xu, Wei
    Fang, Lu
    Cao, Pingxiang
    Guo, Xiaolei
    Ekaved, Mats
    [J]. WOOD RESEARCH, 2017, 62 (05) : 825 - 830
  • [40] ALTERNATIVE TO DROP BALL TEST FOR MEASUREMENT OF OPHTHALMIC GLASS FRACTURE RESISTANCE
    SCAIEF, AL
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (09): : 745 - 745