Improving the standard of the standard for glass ionomers: An alternative to the compressive fracture strength test for consideration?

被引:25
|
作者
Dowling, Adam H. [1 ]
Fleming, Garry J. P. [1 ]
McGinley, Emma L. [1 ]
Addison, Owen [2 ]
机构
[1] Trinity Coll Dublin, Dublin Dent Univ Hosp, Div Oral Biosci, Mat Sci Unit, Dublin 2, Ireland
[2] Univ Birmingham, Biomat Unit, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
Glass ionomer restorative; ISO 9917-1: 2003; Compressive fracture strength; Three point flexure strength; Biaxial flexure strength; Validity; Reliability; CLINICALLY INDUCED VARIABILITY; PHOSPHATE DENTAL CEMENT; AXIAL FLEXURE STRENGTH; TENSILE-STRENGTH; BRITTLE MATERIALS; COMPOSITES; FAILURE; RATIO; FLUOROAPATITE; RESTORATIVES;
D O I
10.1016/j.jdent.2011.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three strength tests (compressive, three point flexure and biaxial) were performed on three glass ionomer (GI) restoratives to assess the most appropriate methodology in terms of validity and reliability. The influence of mixing induced variability on the data sets generated were eliminated by using encapsulated GIs. Methods: Specimen groups of 40 (eight batches of n = 5) cylinders (6.0 +/- 0.1 mm height, 4.0 +/- 0.1 mm diameter) for compressive fracture testing, bars (25.0 +/- 0.1 mm length, 2.0 +/- 0.1 mm height, 2.0 +/- 0.1 mm width) for three point flexure testing and discs (13.0 +/- 0.1 mm diameter, 1.0 +/- 0.1 mm thickness) for biaxial flexure testing were randomly prepared by an operator. The strength data sets for each GI restorative were pooled and one-way analyses of variance (ANOVAs) were conducted to compare between GI restoratives (p = 0.05). The coefficient of variation (CoV) values for each test were pooled and a one-way ANOVA was conducted to test for differences between the reliability of the three tests. Results: For the GI restoratives, the one-way ANOVA showed significant differences when tested in compression (p = 0.001) but not when tested in three point (p = 0.271) or biaxial (p = 0.134) flexure. The pooled CoV values showed no significant difference between the three strength tests (p = 0.632). Conclusions: The compressive fracture strength test specified for GIs in the International Organisation for Standardisation (ISO 9917-1: 2003) should be replaced and should no longer be advocated for the predictive performance modelling of GI restoratives. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:189 / 201
页数:13
相关论文
共 50 条
  • [1] THE EFFECT OF HUMIDITY ON THE COMPRESSIVE STRENGTH OF GLASS IONOMERS
    LIST, G
    LEE, Y
    DHURU, V
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 : 109 - 109
  • [2] Comparison of the compressive strength between different types of glass ionomers
    Hernandez Mata, Alejandra
    [J]. ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2012, 14 : 55 - 58
  • [3] COMPRESSIVE STRENGTH OF FUJI AND KETAC GLASS IONOMERS AFTER SONICATION
    BUTLER, JR
    ARCORIA, CJ
    SIMMONS, JJ
    WAGNER, MJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 : 311 - 311
  • [4] Change in flexural strength and fracture toughness of glass ionomers.
    Miyazaki, M
    Moore, BK
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 424 - 424
  • [5] Panel strength test standard to be divided
    不详
    [J]. FOREST PRODUCTS JOURNAL, 1996, 46 (02) : 6 - 6
  • [6] Study on the standard deviation for the compressive strength of recycled concrete
    Zhang, Xuebing
    Fang, Zhi
    Deng, Shouchang
    [J]. ADVANCES IN CIVIL INFRASTRUCTURE ENGINEERING, PTS 1 AND 2, 2013, 639-640 : 313 - +
  • [7] Comparative Evaluation of Compressive Strength and Fracture Resistance of Posterior Restorative Materials Alkasite and Newer Glass Ionomers with Amalgam: An In Vitro Study
    Kaur, Gurmeen
    Shetty, Chitharanjan
    Hegde, Mithra N.
    [J]. JOURNAL OF INTERNATIONAL ORAL HEALTH, 2022, 14 (06): : 566 - 573
  • [8] Proposed alternative to standard apomorphine challenge test
    Carlos Martinez-Castrillo, Juan
    Andres Burguera, Juan
    [J]. REVISTA DE NEUROLOGIA, 2012, 55 : S11 - S13
  • [9] Improving the reproducibility of soybean standard germination test
    Levan, Nathan A.
    Goggi, A. Susana
    Mullen, Russell
    [J]. CROP SCIENCE, 2008, 48 (05) : 1933 - 1940
  • [10] Dielectric Characterization of Chinese Standard Concrete for Compressive Strength Evaluation
    Chung, Kwok L.
    Yuan, Lei
    Ji, Songtao
    Sun, Li
    Qu, Chengping
    Zhang, Chunwei
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (02):