Attenuation Correction for Fixed MR Components in a Simultaneous PET/MR System

被引:0
|
作者
Xie, Huifang [1 ]
Zhao, Jun [1 ]
Dong, Yun [2 ]
Lv, Yang [2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
[2] Shanghai United Imaging Healthcare Co Ltd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
SEGMENTATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction for fixed MR components like MR table and coils in a simultaneous positron emission tomography and magnetic resonance (PET/MR) system is mandatory for accurate quantification of activity distribution. Conventional methods to derive the attenuation maps of MR table and coils include CT scan and transmission scan. Both methods have their advantages and disadvantages. CT scan method is straightforward, however, the images obtained from CT scan have severe metal artifacts due to wires and circuits, and the attenuation coefficients transformation from X-ray energy to Gamma ray energy needs to be remodeled. Transmission scan method avoids the transformation between different energy levels but needs an extra setup of a rotating rod source (usually (68)Gc) and its resolution is poor. In this work, we aim to combine the merits of these two methods. Instead of complex rotating rod source device, a Ge-68 cylinder source was placed at the center of field of view (FOV) as a stationary emission source. By doing so, the full scan reconstruction problem turned to he a limited angle reconstruction problem. Modified maximum likelihood expectation-maximization (MLEM) algorithm incorporated with Split Bregman algorithm was employed to reconstruct the attenuation map directly from the emission data. An additional CT scan provided the structure information of the MR table and coils, which was used as prior knowledge to confine the region of attenuation coefficients. The proposed method was validated by simulations and real data acquired with a simultaneous PET/MR system.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Verification of the MR components attenuation maps for an MR/PET scanner with simultaneous acquisition
    Eldib, Mootaz
    Faul, David
    Pawlak, John
    Doshi, Niraj
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [2] Attenuation correction for MR table and coils for a sequential PET/MR system
    Zhang, Bin
    Pal, Debashish
    Hu, Zhiqiang
    Ojha, Navdeep
    Guo, Tianrui
    Muswick, Gary
    Tung, Chi-Hua
    Kaste, Jeff
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3303 - 3306
  • [3] Attenuation correction of the PET data with average MR in PET/MR
    Ai, Hua
    Pan, Tinsu
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [4] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [5] Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences
    Park, Chan Rok
    Lee, Youngjin
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (06) : 1610 - 1615
  • [6] Validation of MR-Based Attenuation Correction of a Newly Released Whole-Body Simultaneous PET/MR System
    Liu, Guobing
    Cao, Tuoyu
    Hu, Lingzhi
    Zheng, Jiaxu
    Pang, Lifang
    Hu, Pengcheng
    Gu, Yushen
    Shi, Hongcheng
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [7] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2017, 25 (02) : 245 - +
  • [8] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [9] Addressing PET Attenuation Correction Challenges for the ACR Accreditation of a Simultaneous PET/MR Scanner
    Kulkarni, H.
    Samuels, A.
    Faasse, T.
    Sridhar, V.
    Hu, L.
    Botti, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S693 - S693
  • [10] Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils
    Paulus, Daniel H.
    Braun, Harald
    Aklan, Bassim
    Quick, Harald H.
    MEDICAL PHYSICS, 2012, 39 (07) : 4306 - 4315