Gradient-based 3D-2D Registration of Cerebral Angiograms

被引:1
|
作者
Mitrovic, Uros [1 ]
Markelj, Primoz [1 ,2 ]
Likar, Bostjan [1 ,2 ]
Milosevic, Zoran [3 ]
Pernus, Franjo [1 ,2 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Lab Imaging Technol, Ljubljana 61000, Slovenia
[2] Sensum Comp Vis Syst, Ljubljana 1000, Slovenia
[3] Univ Ljubljana, Fac Med, Dept Radiol, Ljubljana, Slovenia
来源
关键词
3D-2D registration; gold standard; cerebral angiograms; gradient-based; evaluation; CTA; STANDARDIZED EVALUATION METHODOLOGY; 3D/2D REGISTRATION;
D O I
10.1117/12.877541
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Endovascular treatment of cerebral aneurysms and arteriovenous malformations (AVM) involves navigation of a catheter through the femoral artery and vascular system into the brain and into the aneurysm or AVM. Intra-interventional navigation utilizes digital subtraction angiography (DSA) to visualize vascular structures and X-ray fluoroscopy to localize the endovascular components. Due to the two-dimensional (2D) nature of the intra-interventional images, navigation through a complex three-dimensional (3D) structure is a demanding task. Registration of pre-interventional MRA, CTA, or 3D-DSA images and intra-interventional 2D DSA images can greatly enhance visualization and navigation. As a consequence of better navigation in 3D, the amount of required contrast medium and absorbed dose could be significantly reduced. In the past, development and evaluation of 3D-2D registration methods received considerable attention. Several validation image databases and evaluation criteria were created and made publicly available in the past. However, applications of 3D-2D registration methods to cerebral angiograms and their validation are rather scarce. In this paper, the 3D-2D robust gradient reconstruction-based (RGRB) registration algorithm is applied to CTA and DSA images and analyzed. For the evaluation purposes five image datasets, each comprised of a 3D CTA and several 2D DSA-like digitally reconstructed radiographs (DRRs) generated from the CTA, with accurate gold standard registrations were created. A total of 4000 registrations on these five datasets resulted in mean mTRE values between 0.07 and 0.59 mm, capture ranges between 6 and 11 mm and success rates between 61 and 88% using a failure threshold of 2 mm.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] 3D-2D Registration of Cerebral Angiograms Based on Vessel Directions and Intensity Gradients
    Mitrovic, Uros
    Spiclin, Ziga
    Stern, Darko
    Markelj, Primoz
    Likar, Bostjan
    Milosevic, Zoran
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [2] 3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (08) : 1550 - 1563
  • [3] Monoplane 3D-2D registration of cerebral angiograms based on multi-objective stratified optimization
    Aksoy, T.
    Spiclin, Z.
    Pernus, F.
    Unal, G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24): : 9377 - 9394
  • [4] Intensity-based 2-D-3-D registration of cerebral angiograms
    Hipwell, JH
    Penney, GP
    McLaughlin, RA
    Rhode, K
    Summers, P
    Cox, TC
    Byrne, JV
    Noble, JA
    Hawkes, DJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1417 - 1426
  • [5] 3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms
    Mitrovic, Uros
    Likar, Bostjan
    Pernus, Franjo
    Spiclin, Ziga
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (02) : 193 - 202
  • [6] Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [7] Elastic 3D-2D Image Registration
    Striewski, Paul
    Wirth, Benedikt
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2022, 64 (05) : 443 - 462
  • [8] 3D-2D registration of curved objects
    Czopf, Akos
    Brack, Christian
    Roth, Michael
    Schweikard, Achim
    [J]. Periodica Polytechnica, Electrical Engineering, 1999, 43 (01): : 19 - 41
  • [9] Correspondenceless 3D-2D Registration Based on Expectation Conditional Maximization
    Kang, X.
    Taylor, R. H.
    Armand, M.
    Otake, Y.
    Yau, W. P.
    Cheung, P. Y. S.
    Hu, Y.
    [J]. MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [10] 3D-2D IMAGE REGISTRATION BY NONLINEAR REGRESSION
    Gouveia, Ana R.
    Metz, Coert
    Freire, Luis
    Klein, Stefan
    [J]. 2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1343 - 1346