3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images

被引:39
|
作者
Mitrovic, Uros [1 ]
Spiclin, Ziga [1 ]
Likar, Bostjan [1 ]
Pernus, Franjo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, SI-1000 Ljubljana, Slovenia
关键词
Cerebral angiograms; evaluation; gold standard; image-guided interventions; 3D-2D registration; STANDARDIZED EVALUATION METHODOLOGY; 2D-3D REGISTRATION; X-RAY; 2D/3D REGISTRATION; 2-D-3-D REGISTRATION; 3-D/2-D REGISTRATION; RECONSTRUCTION; VALIDATION; FIDUCIALS; VESSELS;
D O I
10.1109/TMI.2013.2259844
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Endovascular image-guided interventions (EIGI) involve navigation of a catheter through the vasculature followed by application of treatment at the site of anomaly using live 2D projection images for guidance. 3D images acquired prior to EIGI are used to quantify the vascular anomaly and plan the intervention. If fused with the information of live 2D images they can also facilitate navigation and treatment. For this purpose 3D-2D image registration is required. Although several 3D-2D registration methods for EIGI achieve registration accuracy below 1 mm, their clinical application is still limited by insufficient robustness or reliability. In this paper, we propose a 3D-2D registration method based on matching a 3D vasculature model to intensity gradients of live 2D images. To objectively validate 3D-2D registration methods, we acquired a clinical image database of 10 patients undergoing cerebral EIGI and established "gold standard" registrations by aligning fiducial markers in 3D and 2D images. The proposed method had mean registration accuracy below 0.65 mm, which was comparable to tested state-of-the-art methods, and execution time below 1 s. With the highest rate of successful registrations and the highest capture range the proposed method was the most robust and thus a good candidate for application in EIGI.
引用
收藏
页码:1550 / 1563
页数:14
相关论文
共 50 条
  • [1] Gradient-based 3D-2D Registration of Cerebral Angiograms
    Mitrovic, Uros
    Markelj, Primoz
    Likar, Bostjan
    Milosevic, Zoran
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [2] 3D-2D Registration of Cerebral Angiograms Based on Vessel Directions and Intensity Gradients
    Mitrovic, Uros
    Spiclin, Ziga
    Stern, Darko
    Markelj, Primoz
    Likar, Bostjan
    Milosevic, Zoran
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [3] Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    [J]. MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [4] Registration of 3D cerebral vessels with 2D digital angiograms: Clinical evaluation
    Bullitt, E
    Liu, A
    Aylward, SR
    Coffey, C
    Stone, J
    Mukherji, SK
    Muller, KE
    Pizer, SM
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (09) : 539 - 546
  • [5] Monoplane 3D-2D registration of cerebral angiograms based on multi-objective stratified optimization
    Aksoy, T.
    Spiclin, Z.
    Pernus, F.
    Unal, G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24): : 9377 - 9394
  • [6] 3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms
    Mitrovic, Uros
    Likar, Bostjan
    Pernus, Franjo
    Spiclin, Ziga
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (02) : 193 - 202
  • [7] 3D-2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
    Otake, Yoshito
    Wang, Adam S.
    Uneri, Ali
    Kleinszig, Gerhard
    Vogt, Sebastian
    Aygun, Nafi
    Lo, Sheng-fu L.
    Wolinsky, Jean-Paul
    Gokaslan, Ziya L.
    Siewerdsen, Jeffrey H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 2075 - 2090
  • [8] Device and methods for "gold standard" registration of clinical 3D and 2D cerebral angiograms
    Madan, Hennadii
    Likar, Bostjan
    Pernus, Franjo
    Spiclin, Ziga
    [J]. MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [9] Intensity-based 2-D-3-D registration of cerebral angiograms
    Hipwell, JH
    Penney, GP
    McLaughlin, RA
    Rhode, K
    Summers, P
    Cox, TC
    Byrne, JV
    Noble, JA
    Hawkes, DJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1417 - 1426
  • [10] 3D-2D registration of curved objects
    Czopf, Akos
    Brack, Christian
    Roth, Michael
    Schweikard, Achim