A method for T1 and T2 relaxation times validation and harmonization as a support to MRI mapping

被引:3
|
作者
Cicolari, Davide [1 ,2 ]
Lizio, Domenico [3 ]
Pedrotti, Patrizia [4 ]
Moioli, Monica Teresa [3 ]
Lascialfari, Alessandro [1 ,2 ]
Mariani, Manuel [1 ,2 ]
Torresin, Alberto [3 ,5 ]
机构
[1] Univ Pavia, Dept Phys, Via Bassi 6, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Pavia Unit, Via Bassi 6, I-27100 Pavia, Italy
[3] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[4] ASST Grande Osped Metropolitano Niguarda, Dept Cardiol, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[5] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
关键词
Relaxation time maps; Data harmonization; Calibration; Accuracy; Precision; INVERSION-RECOVERY MOLLI; HIGH-RESOLUTION T-1; PARAMAGNETIC SOLUTIONS; HUMAN MYOCARDIUM; T1; ACCURACY; REPRODUCIBILITY; PRECISION; CALIBRATION; SEQUENCES;
D O I
10.1016/j.jmr.2021.107110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T-1 and T-2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T-1 and T-2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T-2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T-2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Examination of intermolecular interactions of glutamic acid using T1 and T2 relaxation times
    Petersen, Ellen A.
    Breaux, Carol J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [32] FRONTAL PLANE MALALIGNMENT AND CARTILAGE T1ρ AND T2 RELAXATION TIMES IN KNEE OSTEOARTHRITIS
    Kumar, D.
    Zarins, Z. A.
    Schooler, J.
    Virayavanich, W.
    Li, X.
    Link, T. M.
    Majumdar, S.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S176 - S176
  • [33] Measurement And Processing of Relaxation Times T1 And T2 During The UV Polymerization Process
    Korinek, Radim
    Bartusek, Karel
    Vondrak, Jiri
    Marcon, Petr
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 385 - 390
  • [34] Cutoff points of T1 rho/T2 mapping relaxation times distinguishing early-stage and advanced osteoarthritis
    Yang, Zhijian
    Xie, Chao
    Ou, Songwen
    Zhao, Minning
    Lin, Zhaowei
    ARCHIVES OF MEDICAL SCIENCE, 2022, 18 (04) : 1004 - 1015
  • [35] Determining the effect of water temperature on the T1 and T2 relaxation times of the lung tissue at 9.4 T MRI: A drowning mouse model
    Kodama, Saki
    Hata, Junichi
    Kanawaku, Yoshimasa
    Nakagawa, Hiroshi
    Oshiro, Hinako
    Saiki, Erisha
    Okano, Hirotaka J.
    Iwadate, Kimiharu
    LEGAL MEDICINE, 2021, 49
  • [36] Repeatability of Quantitative Knee Cartilage T1, T2, and T1ρ Mapping With 3D-MRI Fingerprinting
    Zhang, Xiaoxia
    de Moura, Hector L.
    Monga, Anmol
    Zibetti, Marcelo V. W.
    Kijowski, Richard
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (02) : 688 - 699
  • [37] Comparison of MRI T1, T2, and T2*mapping with histology for assessment of intervertebral disc degeneration in an ovine model
    Bouhsina, Nora
    Decante, Cyrille
    Hardel, Jean-Baptiste
    Rouleau, Dominique
    Abadie, Jerome
    Hamel, Antoine
    Le Visage, Catherine
    Lesoeur, Julie
    Guicheux, Jerome
    Clouet, Johann
    Fusellier, Marion
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [38] 7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers
    Andrea Lazik
    Jens M. Theysohn
    Christina Geis
    Sören Johst
    Mark E. Ladd
    Harald H. Quick
    Oliver Kraff
    European Radiology, 2016, 26 : 1245 - 1253
  • [39] Comparison of MRI T1, T2, and T2* mapping with histology for assessment of intervertebral disc degeneration in an ovine model
    Nora Bouhsina
    Cyrille Decante
    Jean-Baptiste Hardel
    Dominique Rouleau
    Jérôme Abadie
    Antoine Hamel
    Catherine Le Visage
    Julie Lesoeur
    Jérôme Guicheux
    Johann Clouet
    Marion Fusellier
    Scientific Reports, 12
  • [40] T1/T2 AND SPIN RELAXATION IN BENZENE ANION
    FREED, JH
    KOOSER, RG