A method for T1 and T2 relaxation times validation and harmonization as a support to MRI mapping

被引:3
|
作者
Cicolari, Davide [1 ,2 ]
Lizio, Domenico [3 ]
Pedrotti, Patrizia [4 ]
Moioli, Monica Teresa [3 ]
Lascialfari, Alessandro [1 ,2 ]
Mariani, Manuel [1 ,2 ]
Torresin, Alberto [3 ,5 ]
机构
[1] Univ Pavia, Dept Phys, Via Bassi 6, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Pavia Unit, Via Bassi 6, I-27100 Pavia, Italy
[3] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[4] ASST Grande Osped Metropolitano Niguarda, Dept Cardiol, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[5] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
关键词
Relaxation time maps; Data harmonization; Calibration; Accuracy; Precision; INVERSION-RECOVERY MOLLI; HIGH-RESOLUTION T-1; PARAMAGNETIC SOLUTIONS; HUMAN MYOCARDIUM; T1; ACCURACY; REPRODUCIBILITY; PRECISION; CALIBRATION; SEQUENCES;
D O I
10.1016/j.jmr.2021.107110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T-1 and T-2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T-1 and T-2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T-2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T-2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Validation of a T1 and T2 mapping software for quantitative MRI
    Sebastian Bidhult
    Georgios Kantasis
    Anthony H Aletras
    Einar Heiberg
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [2] RELAXATION TIMES T1 AND T2 IN ANTHRACITE
    GARIFIANOV, NS
    KOZYREV, BM
    SOVIET PHYSICS JETP-USSR, 1957, 3 (06): : 952 - 952
  • [3] MRI of Splenic Sarcoidosis with T1 and T2 Mapping
    Camastra, Giovanni
    Ciolina, Federica
    RADIOLOGY, 2024, 310 (02)
  • [4] MUSCULOSKELETAL TUMORS - T1 AND T2 RELAXATION-TIMES
    PETTERSSON, H
    SLONE, RM
    SPANIER, S
    GILLESPY, T
    FITZSIMMONS, JR
    SCOTT, KN
    RADIOLOGY, 1988, 167 (03) : 783 - 785
  • [5] THE RELATION BETWEEN T1 AND T2 RELAXATION-TIMES
    SKINNER, JL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 44 - PHYS
  • [6] Three-dimensional simultaneous T1 and T2*relaxation times and quantitative susceptibility mapping at 3 T: A multicenter validation study
    Fujita, Shohei
    Hagiwara, Akifumi
    Kimura, Koichiro
    Taniguchi, Yo
    Ito, Kosuke
    Nagao, Hisako
    Takizawa, Masahiro
    Uchida, Wataru
    Kamagata, Koji
    Tateishi, Ukihide
    Aoki, Shigeki
    MAGNETIC RESONANCE IMAGING, 2024, 112 : 100 - 106
  • [7] A novel alternative to classify tissues from T1 and T2 relaxation times for prostate MRI
    Jorge Zavala Bojorquez
    Stéphanie Bricq
    François Brunotte
    Paul M. Walker
    Alain Lalande
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 777 - 788
  • [8] NUCLEAR MAGNETIC RELAXATION TIMES T1 AND T2 IN SOME LIQUIDS
    BONERA, G
    CHIODI, L
    LANZI, G
    RIGAMONTI, A
    NUOVO CIMENTO, 1960, 17 (02): : 198 - 204
  • [9] T1ρ and T2 relaxation times predict progression of knee osteoarthritis
    Prasad, A. P.
    Nardo, L.
    Schooler, J.
    Joseph, G. B.
    Link, T. M.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 69 - 76
  • [10] T1ρ and T2 relaxation times are associated with progression of hip osteoarthritis
    Gallo, M. C.
    Wyatt, C.
    Pedoia, V.
    Kumar, D.
    Lee, S.
    Nardo, L.
    Link, T. M.
    Souza, R. B.
    Majumdar, S.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 (08) : 1399 - 1407