Novel registration-based image enhancement for x-ray fluoroscopy

被引:0
|
作者
Dixon, Adam [1 ]
Areste, Romain [1 ]
Jabri, Kadri N. [1 ]
Walimbe, Vivek [1 ]
机构
[1] GE Healthcare, Global Diagnost Xray Engn, Waukesha, WI 53188 USA
来源
关键词
Image Registration; X-ray Fluoroscopy; Image Quality; Last Image Hold;
D O I
10.1117/12.844498
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High image noise in low-dose fluoroscopic x-ray often necessitates additional radiographic-dose exposures to patients to include as part of the medical records. We present an image registration based approach for the generation of high-quality images from a sequence of low-dose x-ray fluoroscopy exposures. Image subregions in consecutively acquired fluoroscopy frames are registered to subregions in a pre-selected reference frame using a two-dimensional transformation model. Frames neighboring the reference image are resampled using a smooth deformation field generated by interpolation of the individual subregion deformations. Motion-corrected neighboring frames are then combined with the reference frame using a weighted, frequency-specific multi-resolution combination method. Using this method, image noise (localized standard deviation) was reduced by 38% in phantom data and by 29% in clinical barium swallow examinations. We demonstrate an effective method for generating a simulated radiographic-dose x-ray image from a set of consecutively acquired low-dose fluoroscopy images. The significant improvement in image quality indicates the potential of this approach to lower average patient dose by substantially reducing the need for additional exposures for patient records.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] CHARACTERIZATION OF THE VEILING GLARE PSF IN X-RAY IMAGE INTENSIFIED FLUOROSCOPY
    SEIBERT, JA
    NALCIOGLU, O
    ROECK, WW
    [J]. MEDICAL PHYSICS, 1984, 11 (02) : 172 - 179
  • [42] A Segmentation Method for Mammogram X-ray Image Based on Image Enhancement with Wavelet Fusion
    Liang Zhengyou
    Gou Xiaoshan
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS RESEARCH AND MECHATRONICS ENGINEERING, 2015, 121 : 122 - 129
  • [43] X-ray Image Enhancement Based on Adaptive Gradient Domain Guided Image Filtering
    Li, Liangliang
    Lv, Ming
    Ma, Hongbing
    Jia, Zhenhong
    Yang, Xinghua
    Yang, Weiyi
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [44] A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system
    Gutierrez, Luis F.
    Ozturk, Cengizhan
    McVeigh, Elliot R.
    Lederman, Robert J.
    [J]. MEDICAL PHYSICS, 2008, 35 (03) : 997 - 1007
  • [45] X-ray mammogram registration: A novel validation method
    Hipwell, John H.
    Tanner, Christine
    Crum, William R.
    Hawkes, David J.
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 197 - 204
  • [46] 3D TEE Registration with X-Ray Fluoroscopy for Interventional Cardiac Applications
    Jain, Ameet
    Gutierrez, Luis
    Stanton, Douglas
    [J]. FUNCTIONAL IMAGING AND MODELING OF THE HEART, PROCEEDINGS, 2009, 5528 : 321 - 329
  • [47] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    [J]. MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [48] A new method for registration-based medical image interpolation
    Frakes, David H.
    Dasi, Lakshmi P.
    Pekkan, Kerem
    Kitajima, Hiroumi D.
    Sundareswaran, Kartik
    Yoganathan, Ajit P.
    Smith, Mark J. T.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (03) : 370 - 377
  • [49] X-RAY PROTECTION IN INDUSTRIAL FLUOROSCOPY
    HENNY, GC
    [J]. RADIOLOGY, 1946, 46 (01) : 66 - 69
  • [50] X-RAY FLUOROSCOPY FOR AIRCRAFT INSPECTION
    不详
    [J]. METAL CONSTRUCTION AND BRITISH WELDING JOURNAL, 1972, 4 (09): : 350 - &