Physiologically Self-Regulated, Fully Implantable, Battery-Free System for Peripheral Nerve Restoration

被引:64
|
作者
Jin, Fei [1 ]
Li, Tong [1 ]
Yuan, Tao [2 ]
Du, Lijuan [1 ]
Lai, Chengteng [2 ,3 ]
Wu, Qi [2 ,3 ]
Zhao, Ying [1 ]
Sun, Fengyu [1 ]
Gu, Long [4 ]
Wang, Ting [5 ]
Feng, Zhang-Qi [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Chem & Chem Engn, Nanjing 210094, Peoples R China
[2] Nanjing Jinling Hosp, Dept Orthoped, Nanjing 210002, Peoples R China
[3] Nanjing Univ, Med Sch, Nanjing 210002, Peoples R China
[4] Xidian Univ, Sch Adv Mat & Nanotechnol, Xian 710071, Peoples R China
[5] Southeast Univ, State Key Lab Bioelect, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
electrical stimulation; implants; nanogenerators; nerve guide conduits; peripheral nerve restoration; ELECTRICAL-STIMULATION; CONDUCTING POLYMERS; REGENERATION;
D O I
10.1002/adma.202104175
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The long-segment peripheral nerve injury (PNI) represents a global medical challenge, leading to incomplete nerve tissue recovery and unsatisfactory functional reconstruction. However, the current electrical stimulation (ES) apparatuses fail perfect nerve repair due to their inability of the variable synchronous self-regulated function with physiological states. It is urgent to develop an implantable ES platform with physiologically adaptive function to provide instantaneous and nerve-preferred ES. Here, a physiologically self-regulated electrical signal is generated by integrating a novel tribo/piezoelectric hybrid nanogenerator with a nanoporous nerve guide conduit to construct a fully implantable neural electrical stimulation (FI-NES) system. The optimal neural ES parameters completely originate from the body itself and are highly self-responsive to different physiological states. The morphological evaluation, representative protein expression level, and functional reconstruction of the regenerated nerves are conducted to assess the PNI recovery process. Evidence shows that the recovery effect of 15 mm length nerve defects under the guidance of the FI-NES system is significantly close to the autograft. The designed FI-NES system provides an effective method for long-term accelerating the recovery of PNI in vivo and is also appropriate for other tissue injury or neurodegenerative diseases.
引用
收藏
页数:12
相关论文
共 29 条
  • [21] Soft, Implantable, Battery-Free, and Wirelessly Controlled Optoelectronic System for Obstructive Sleep Apnea Treatment
    Battistini, Giulia
    Augello, Elisa
    Paolini, Giacomo
    Bastianini, Stefano
    Zoccoli, Giovanna
    Masotti, Diego
    Costanzo, Alessandra
    [J]. 2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024, 2024, : 87 - 89
  • [22] A Conformal Wireless Power System for Battery-Free Implantable Optogenetic Treatment of Obstructive Sleep Apnea
    Augello, Elisa
    Battistini, Giulia
    Paolini, Giacomo
    Bastianini, Stefano
    Zoccoli, Giovanna
    Costanzo, Alessandra
    [J]. 2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 166 - 168
  • [23] Novel spinal cord stimulation system with a Battery-Free micro-implantable pulse generator
    Malinowski, Mark N.
    Heit, Gary
    Poree, Lawrence R.
    Makous, James
    Amirdelfan, Kasra
    [J]. PAIN PRACTICE, 2022, 22 (06) : 592 - 599
  • [24] A reliable, battery-free and implantable magnetic sensing system for wireless monitoring of spinal motion in rats and humans
    Shi, Yunsong
    Tang, Sihan
    Zhang, Weifeng
    Lei, Chunchi
    Feng, Xiaobo
    Wang, Kun
    Yue, Yamei
    Wang, Qi
    Chen, Annan
    Su, Jin
    Zhao, Hu
    Yan, Chunze
    Tian, Yujia
    Zhou, Kun
    Lu, Jian
    Yang, Cao
    Su, Bin
    [J]. CHEMICAL ENGINEERING JOURNAL, 2024, 482
  • [25] A Fully Implantable Wireless Optofluidic Nerve Cuff System for Tether-Free Optogenetic and Pharmacologic Manipulation of Peripheral Nerves
    Mickle, A.
    Gereau, R.
    Mcllvried, L.
    Golden, J.
    Grajales-Reyes, J.
    Zhang, Y.
    Rogers, J.
    [J]. JOURNAL OF PAIN, 2019, 20 (04): : S30 - S31
  • [26] Intrinsically Self-powered, Battery-free, and Sensor-free Ambient Light Control System
    La Rosa, Roberto
    Costanza, Mario
    Burg, Andreas
    Dehollain, Catherine
    Livreri, Patrizia
    [J]. 2021 IEEE SENSORS, 2021,
  • [27] Vascular Electrical Stimulation with Wireless, Battery-Free, and Fully Implantable Features Reduces Atherosclerotic Plaque Formation Through Sirt1-Mediated Autophagy
    Wang, Pengyu
    Li, Manman
    Gao, Tielei
    Fan, Jiaying
    Zhang, Dengfeng
    Zhao, Ying
    Zhao, Yajie
    Wang, Yuqin
    Guo, Tianwei
    Gao, Xi
    Liu, Yujun
    Gao, Yang
    Guan, Xue
    Sun, Xinyong
    Zhao, Jiyi
    Li, Hong
    Yang, Liming
    [J]. SMALL, 2023, 19 (40)
  • [28] Restoration of orbicularis oculi muscle function in rabbits with peripheral facial paralysis via an implantable artificial facial nerve system
    Sun, Yajing
    Jin, Cheng
    Li, Keyong
    Zhang, Qunfeng
    Geng, Liang
    Liu, Xundao
    Zhang, Yi
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (06) : 5289 - 5296
  • [29] One-stone-two-birds: engineering a 2D layered heterojunction of terbium tungstate incorporated on molybdenum disulfide nanosheets for a battery-free self-charging power system via the integration of a wearable piezoelectric nanogenerator and an asymmetric supercapacitor
    Sasikumar, Ragu
    Kim, Byungki
    Mok, Young Sun
    Bhattarai, Roshan Mangal
    [J]. Advanced Composites and Hybrid Materials, 2024, 7 (06)