Detection, quantification and confirmation of anabolic steroids in equine plasma by liquid chromatography and tandem mass spectrometry

被引:79
|
作者
Guan, FY
Uboh, CE
Soma, LR
Luo, Y
Rudy, J
Tobin, T
机构
[1] Univ Penn, Sch Vet Med, Dept Clin Studies, Kennett Sq, PA 19348 USA
[2] W Chester Univ, Dept Chem, PA Equine Toxicol & Res Ctr, W Chester, PA 19382 USA
[3] Univ Kentucky, Max H Gluck Equine Res Ctr, Lexington, KY 40546 USA
[4] Univ Kentucky, Dept Vet Sci, Lexington, KY 40546 USA
关键词
anabolic steroid; LC-MS; plasma; horse; doping control; THG; testosterone; boldenone;
D O I
10.1016/j.jchromb.2005.09.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Anabolic androgenic steroids are related to the male sex hormones and are abused in equine sports. In an effort to deter the abuse of anabolic steroids, a sensitive LC-MS/MS method was developed for detection, quantification and confirmation of eight major anabolic steroids (testosterone, normethandrolone, nandrolone, boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, and stanozolol) in equine plasma. Formation of solvent adduct ions of the analytes was observed under electrospray ionization (ESI) conditions, and desolvation of the solvent adduct ions by source collision-induced decomposition (CID) increased the abundance of the [M + H](+) ions as well as the multiple-reaction monitoring (MRM) signals. ESI (+) and APCI (+) were compared with respect to sensitivity for the analytes and the former provided better sensitivity. The matrix effect on ion suppression or enhancement was evaluated, and was negligible. Confirmation of the analytes was performed using criteria of three ion transitions and LC retention time of each analyte. The limit of detection (LOD) and quantification (LOQ) was 25 pg/mL. The limit of confirmation (LOC) was 25 pg/mL for boldenone; 50 pg/mL for normethandrolone, nandrolone, and methandrostenolone; and 100 pg/mL for testosterone, THG, trenbolone, and stanozolol. The analytes were evaluated for stability and found to be stable in plasma for 24 It at room temperature, 13 days at 4 degrees C, and 34 days at -20 and -70 degrees C. The method was successfully applied to analyses of equine plasma samples for pharmacokinetics study. This method is sensitive and useful for detection, quantification and confirmation of these anabolic steroids in equine plasma. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 68
页数:13
相关论文
共 50 条
  • [31] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Giuliana Cangemi
    Sebastiano Barco
    Roberto Bandettini
    Elio Castagnola
    [J]. Analytical and Bioanalytical Chemistry, 2014, 406 : 1795 - 1798
  • [32] Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma
    Kong, Tae Yeon
    Ji, Hye Young
    Choi, Sang-Zin
    Son, Miwon
    Lee, Hye Suk
    [J]. MASS SPECTROMETRY LETTERS, 2013, 4 (03) : 55 - 58
  • [33] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Cangemi, Giuliana
    Barco, Sebastiano
    Bandettini, Roberto
    Castagnola, Elio
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1795 - 1798
  • [34] Quantification of clopidogrel in human plasma by sensitive liquid chromatography/tandem mass spectrometry
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1695 - 1700
  • [35] Liquid chromatography/tandem mass spectrometry assay for the quantification of troxerutin in human plasma
    Liu, Fei
    Xu, Yu
    Rui, Lei
    Gao, Shu
    Dong, Haijun
    Guo, Qingxiang
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (23) : 3522 - 3526
  • [36] Quantification of metaxalone in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Shrivastava, W
    Datla, PV
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2006, 30 (04) : 245 - 251
  • [37] Rapid quantification of lisinopril in human plasma by liquid chromatography/tandem mass spectrometry
    Qin, Weiwei
    Zhang, Zunjian
    Tian, Yuan
    Xu, Fengguo
    Wang, Na
    Chen, Yun
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (04) : 415 - 421
  • [38] Quantification of vigabatrin in human plasma by liquid chromatography - Electrospray tandem mass spectrometry
    Matar, KM
    Abdel-Hamid, ME
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 395 - 406
  • [39] Sensitive liquid chromatography tandem mass spectrometry method for the quantification of Quetiapine in plasma
    Nirogi, Ramakrishna
    Bhyrapuneni, Gopinadh
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Ajjala, Devender
    Mukkanti, K.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (10) : 1043 - 1055
  • [40] Quantification of rabeprazole in human plasma by liquid chromatography-tandem mass spectrometry
    Zhang, Y
    Chen, XY
    Gu, Q
    Zhong, DF
    [J]. ANALYTICA CHIMICA ACTA, 2004, 523 (02) : 171 - 175