Transport channels of X-ray beamlines at SPring-8

被引:3
|
作者
Goto, S [1 ]
Ohashi, H
Takeshita, K
Yabashi, M
Yamakata, A
Asano, Y
Ishikawa, T
机构
[1] JASRI, SPring 8, Mikazuki, Hyogo 6795198, Japan
[2] JAERI, SPring 8, Mikazuki, Hyogo 6795148, Japan
[3] RIKEN, SPring 8, Mikazuki, Hyogo 6795148, Japan
关键词
synchrotron radiation beamline; SPring-8; beamline transport channel;
D O I
10.1016/S0168-9002(01)00460-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
SPring-8 constructed various X-ray beamline transport channels using standard components and newly developed components to cope with the various light sources and optics. Sophisticated short-length undulator beamline such as high resolution inelastic beamline, medium-length beamlines ranging 100-200 m, and 1 km-long beamline have been constructed as well as standard short-length beamlines. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:813 / 815
页数:3
相关论文
共 50 条
  • [21] Soft X-ray beamline for spectroscopy of solids at SPring-8
    Saitoh, Y
    Kimura, H
    Suzuki, Y
    Nakatani, T
    Matsushita, T
    Muro, T
    Miyahara, T
    Fujisawa, A
    Soda, K
    Ueda, S
    Sekiyama, A
    Imada, S
    Suga, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 553 - 556
  • [22] Micro X-ray CT at spring-8 for granular mechanics
    Matsushima, Takashi
    Katagiri, Jun
    Uesugi, Kentaro
    Nakano, Tsukasa
    Tsuchiyama, Akira
    SOIL STRESS-STAIN BEHAVIOR: MEASUREMENT, MODELING AND ANALYSIS, 2007, 146 : 225 - +
  • [23] Upgrade of surface profiler for X-ray mirror at SPring-8
    Senba, Y.
    Kishimoto, H.
    Miura, T.
    Ohashi, H.
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS V, 2014, 9206
  • [24] A compact X-ray free electron laser at SPring-8
    Ishikawa, Tetsuya
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C151 - C151
  • [25] Proposal for medical application beamlines of the SPring-8
    Uyama, C
    Tokumori, K
    Toyofuku, F
    Sugiyama, H
    Hyodo, K
    Ando, M
    Nishimura, K
    Takeda, T
    Yamasaki, K
    Matsumoto, M
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 193 - 204
  • [26] RIKEN STRUCTURAL GENOMICS BEAMLINES AT SPring-8
    Yamamoto, M.
    Kumasaka, T.
    Ueno, G.
    Ida, K.
    Kanda, H.
    Miyano, M.
    Ishikawa, T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C302 - C302
  • [27] Ultra-small-angle X-ray diffraction and scattering experiments using medium-length beamlines at SPring-8
    Yagi, N
    Inoue, K
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2003, 36 (01) : 783 - 786
  • [28] Pharmaceutical Application of Synchrotron X-ray Powder Diffraction at SPring-8
    Miura, Keiko
    Kitano, Akiko
    Komiya, Satoshi
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C488 - C488
  • [29] Refractive X-ray lens for high pressure experiments at SPring-8
    Ohishi, Y
    Baron, AQR
    Ishii, M
    Ishikawa, T
    Shimomura, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 962 - 965
  • [30] Results of a search for paraphotons with intense X-ray beams at SPring-8
    Inada, T.
    Namba, T.
    Asai, S.
    Kobayashi, T.
    Tanaka, Y.
    Tamasaku, K.
    Sawada, K.
    Ishikawa, T.
    PHYSICS LETTERS B, 2013, 722 (4-5) : 301 - 304