Analysis, Design, and Preliminary Evaluation of a Parallel Elastic Actuator for Power-Efficient Walking Assistance

被引:6
|
作者
Li, Yinbo [1 ]
Guan, Xinyu [1 ]
Li, Zhibin [1 ]
Tang, Zihan [1 ]
Penzlin, Bernhard [2 ]
Yang, Ze [3 ]
Leonhardt, Steffen [2 ]
Ji, Linhong [1 ]
机构
[1] Tsinghua Univ, Div Intelligent & Biomimet Machinery, State Key Lab Tribol, Beijing 100084, Peoples R China
[2] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-52074 Aachen, Germany
[3] China Univ Geosci, Sch Engn & Technol, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Actuator design; compliant actuation; lower limb exoskeleton; parallel elastic actuator; power-efficient actuator; ENERGY-CONSUMPTION; OPTIMIZATION; EXOSKELETON; ELEMENTS; SPRINGS; JOINT; ROBOT;
D O I
10.1109/ACCESS.2020.2993183
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper introduces the analysis, design and preliminary evaluation of a self-integrated parallel elastic actuator (PEA) with an electric motor and a flat spiral spring in parallel to drive the hip joint of lower limb exoskeletons for power-efficient walking assistance. Firstly, we quantitatively analyze the reason why the parallel elasticity (PE) placed at the sagittal hip joint can reduce the motor power requirement during walking assistance, which contributes to the theory of PEA development and application. The design of the PEA is then introduced in detail. The novelty of the design is that the actuator is reduced in size by integrating the spring into the motor, and the requirement of spring stiffness is significantly reduced by placing the spring directly parallel to the motor shaft. Furthermore, both the simulation based on dynamic modeling and benchtop experiment are conducted preliminarily to evaluate the performance of the PEA with nine spring stiffnesses in a range from 0 5.29 mN.m/rad regarding two indexes including the average and maximum positive electrical power of the motor. Their results show that the two indexes become smaller when the PE is attached and decrease as the spring stiffness increases. When the PE with a stiffness of 5.29 mN.m/rad is attached, the actuator obtains the largest reduction rate of 11.99 and 16.84 % in the average (root mean square) and maximum positive electrical power of the motor in the simulation and 10.3 and 26.25 % in the experiment, respectively. Those results provide evidence for the applicability of the newly designed PEA in driving a lower limb exoskeleton with high power efficiency during walking assistance for paraplegic patients with complete loss in walking ability.
引用
收藏
页码:88060 / 88075
页数:16
相关论文
共 50 条
  • [1] A Power-Efficient Magnetic Actuator Driver Design
    Kebapcioglu, Berkay
    Ferhanoglu, Onur
    Yelten, Mustafa Berke
    2022 29TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (IEEE ICECS 2022), 2022,
  • [2] Design of a Series Elastic Tendon Actuator Based on Gait Analysis for a Walking Assistance Exosuit
    Lee, Hee Don
    Moon, Jeon Il
    Kang, Tae Hun
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2019, 17 (11) : 2940 - 2947
  • [3] Design of a Series Elastic Tendon Actuator Based on Gait Analysis for a Walking Assistance Exosuit
    Hee Don Lee
    Jeon Il Moon
    Tae Hun Kang
    International Journal of Control, Automation and Systems, 2019, 17 : 2940 - 2947
  • [4] Strategy for power-efficient design of parallel systems
    Danckaert, K
    Masselos, K
    Catthoor, F
    De Man, HJ
    Goutis, C
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 1999, 7 (02) : 258 - 265
  • [5] Design and evaluation of a serial elastic actuator for human assistance
    Gerlach-Hahn, Kurt
    Dahmen, Christian
    Misgeld, Berno J. E.
    Leonhardt, Steffen
    2013 XXIV INTERNATIONAL SYMPOSIUM ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT), 2013,
  • [6] Design of power-efficient parallel pipelined Bloom filter
    Kim, Deokho
    Oh, Doohwan
    Ro, Won W.
    ELECTRONICS LETTERS, 2012, 48 (07) : 367 - U98
  • [7] Design and Analysis of a Clutched Parallel Elastic Actuator
    Penzlin, Bernhard
    Fincan, Mustafa Enes
    Li, Yinbo
    Ji, Linhong
    Leonhardt, Steffen
    Chuong Ngo
    ACTUATORS, 2019, 8 (03)
  • [8] Analysis and design of power-efficient coding schemes with parallel concatenated convolutional codes
    Huettinger, Simon
    Huber, Johannes
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2006, 54 (07) : 1251 - 1258
  • [9] FOURIER ANALYSIS GUIDED CABLE ACTUATOR DESIGN FOR COORDINATED WALKING ASSISTANCE
    Liu, Chong
    Hidayah, Rand
    Agrawal, Sunil
    PROCEEDINGS OF ASME 2021 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2021, VOL 8A, 2021,
  • [10] Design and Evaluation of a Series-Elastic Gyroscopic Actuator for Balance Assistance
    Marquardt, Charlotte
    Lemus, Daniel
    Meijneke, Cory
    Vallery, Heike
    2021 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2021, : 781 - 786