Awareness of guidelines for use of automated external defibrillators in children within emergency medical services

被引:6
|
作者
Haskell, Sarah E. [1 ]
Kenney, Melanie A. [1 ]
Patel, Sonali [1 ]
Sanddal, Teri L. [2 ]
Altenhofen, Katrina L. [2 ,3 ]
Sanddal, Nels D. [2 ]
Atkins, Dianne L. [1 ]
机构
[1] Univ Iowa, Div Pediat Cardiol, Childrens Hosp, Carver Coll Med,Dept Pediat, 200 Hawkins Dr, Iowa City, IA 52242 USA
[2] Crit Illness & Trauma Fdn Inc, Bozeman, MT USA
[3] Iowa Dept Publ Hlth, Des Moines, IA 50319 USA
关键词
cardiopulmonary resuscitation; automated external defibrillator; children; guidelines; education;
D O I
10.1016/j.resuscitation.2007.08.012
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Ventricular fibrillation occurs in 10-20% of pediatric cardiac arrests. Survival rates in children with ventricular fibrillation can be as high as 30% when the rhythm is identified and treated promptly. In the last 5 years, recommendations have been made for the use of automated external defibrillators in children between 1 and 8 years of age. Objective: The goal of this study was to determine the awareness of the ILCOR guidelines and statewide protocols concerning AED use in children ages 1-8 among emergency medical. providers after new guideline release. Availability of pediatric capable AED equipment was also assessed. Methods: Surveys were distributed to EMS providers in Iowa and Montana within 1 year of the ILCOR advisory statement in 2003 recommending use of AEDs in children ages 1-8, and again approximately 1 year after the 2005 ILCOR guidelines on cardiopulmonary resuscitation were published. In Iowa, there were concentrated efforts to disseminate information about AED use in children, white there were minimal efforts in Montana. Results: Awareness of ILCOR guidelines for use of AEDs in children was low in both states in 2003 (29% in Iowa vs. 9% in Montana, p<0.001). After release of the 2005 guidelines, awareness improved significantly in both states but was still significantly greater in Iowa (83% vs. 60%, p<0.002). In 2003, less than 20% of respondents in both states reported access to pediatric capable AEDs. Availability of pediatric pads and cables increased significantly in 2006 but remained tow in Montana (74% in Iowa vs. 37% in Montana, p<0.001). Conclusions: At the present time, publication of new or interim guidelines in the scientific literature alone is insufficient to ensure that new protocols are implemented. An effective and efficient method to disseminate new pediatric out-of-hospital protocols emergency care to become standard of care in a timely matter must be developed. (c) 2007 Published by Elsevier Ireland Ltd.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 50 条
  • [41] Home use of automated external defibrillators for sudden cardiac arrest
    Bardy, Gust H.
    Lee, Kerry L.
    Mark, Daniel B.
    Poole, Jeanne E.
    Toff, William D.
    Tonkin, Andrew M.
    Smith, Warren
    Dorian, Paul
    Packer, Douglas L.
    White, Roger D.
    Longstreth, W. T., Jr.
    Anderson, Jill
    Johnson, George
    Bischoff, Eric
    Yallop, Julie J.
    McNulty, Steven
    Ray, Linda Davidson
    Clapp-Channing, Nancy E.
    Rosenberg, Yves
    Schron, Eleanor B.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (17): : 1793 - 1804
  • [42] GUIDELINES FOR EMERGENCY MEDICAL-SERVICES SYSTEMS
    不详
    ANNALS OF EMERGENCY MEDICINE, 1988, 17 (07) : 742 - 745
  • [43] SAEM emergency medical services fellowship guidelines
    Marx, JA
    ACADEMIC EMERGENCY MEDICINE, 1999, 6 (10) : 1069 - 1070
  • [44] Cardiac arrest in medical and dental practices - Implications for automated external defibrillators
    Becker, L
    Eisenberg, M
    Fahrenbruch, C
    Cobb, L
    ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (12) : 1509 - 1512
  • [45] Delivery of Automated External Defibrillators (AED) by Drones: Implications for Emergency Cardiac Care
    Zègre-Hemsey J.K.
    Bogle B.
    Cunningham C.J.
    Snyder K.
    Rosamond W.
    Current Cardiovascular Risk Reports, 2018, 12 (11)
  • [46] Field deployment of automated external defibrillators to a federal fire service unit under medical direction of a military emergency service
    Gerhardt, RT
    Wiegert, R
    Newell, SK
    Gerhardt, DM
    Gaither, P
    MILITARY MEDICINE, 1999, 164 (12) : 877 - 880
  • [47] Even children can use automatic external defibrillators
    Pirisi, A
    LANCET, 1999, 354 (9188): : 1449 - 1449
  • [48] Can Automated External Defibrillators Be Used Correctly by Adults and Children With No Training
    Lev, R.
    Lee, K.
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (04) : S88 - S89
  • [49] Prehospital use of spinal precautions by emergency medical services in children and adolescents
    Phillips, Natalie
    Eapen, Nitaa
    Wilson, Catherine L.
    Nehme, Ziad
    Babl, Franz E.
    EMERGENCY MEDICINE AUSTRALASIA, 2025, 37 (01)
  • [50] Automated external defibrillators in the public domain - AmI ready to use one?
    Estes, NAM
    CIRCULATION, 2005, 112 (24) : E349 - E351