Characteristics of Sludge Node Operation at Wastewater Treatment Plant in Zory

被引:0
|
作者
Zdebik, Dariusz [1 ]
Zawadzki, Piotr [1 ]
Pieczonka, Michal [2 ]
机构
[1] Cent Min Inst, Katowice, Poland
[2] Zory Water Supply & Sewage Co, Zory, Poland
来源
ROCZNIK OCHRONA SRODOWISKA | 2019年 / 21卷 / 02期
关键词
wastewater treatment plant; activated sludge; sewage sludges; quality of the wastewater; leachate; sewage sludge management; REJECT;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this work was to analyze work of the sludge part of the wastewater treatment plant in Zory. During the analysed period (years 2015-2017) the wastewater treatment plant in Zory worked in conditions typical for the municipal facilities. The characterization of the sludge generated in the wastewater treatment process has also shown that the sludge properties are typical for the municipal wastewater treatment plants. Based on the data provided by the PWiK Sp. z o. o. in Zory. the characteristics of the technological process were made. This characteristics in a detailed way includes the sludge part of the treatment plant. The analysis of the functioning of the sludge part was performed and the influence of the pollutants load in leachates on the effectiveness of work in the main technological line was characterized. Studies on the functioning of the sludge part showed discrepancies between the design status of the wastewater treatment plant and the real state. This is due to the increasing amount of the wastewater flowing into the treatment plant and the associated increase in the amount of the occurring sludge. The belt press and the digested sludge tank are particularly loaded. The belt press works for about 11.9 h/d with assumed 4.1 h/d. In turn. the residence time of the sludge in the digested sludge tank is about 3 times shorter than assumed. Despite the observed. increasing concentrations of pollutants and the amount of treated wastewater. the plant meets the legal requirements regarding the quality of the wastewater discharged to the receiver by the water-legal permit and the Regulation of the Minister of the Environment. Based on the results of laboratory tests of the wastewater and leachates generated in the process of dewatering on the filter presses. their impact on the efficiency of treatment in the main technological line was characterized. The amount of leachates in relation to the amount of the wastewater flowing into the treatment plant was 1.8%. The leachates had high content of ammonium nitrogen. total phosphorus and total suspended solids. The average concentrations of these parameters were: S-NNH4 = 592.6 mg/dm(3), S-Nog = 664.8 mg/dm(3), S-Pog = 197.7 mg/dm(3) and S-zo(g) = 1100.9 mg/dm(3). The average values of BOD5 and COD indices were S-BOD5 = 66.4 mg/dm(3), and S-COD = 386.9 mg/dm(3). The leachates coming from the filter presses carried a significant load of total phosphorus. which constituted on average 27.3% of the total load flowing into the treatment plant. as well as the total suspension and total nitrogen. which maximum load constituted 7.3% (Z(og)) and 11.8% (N-og) of the total load flowing into the treatment plant. The ratio of COD/BOD5 indices of pollutants of the leachates from the presses was 5.83. which indicated the introduction of hardly biodegradable compounds into the main technological line. In order to increase the efficiency of nitrogen removal in the main technological line it was proposed the implementation of deammonification process of the leachates from the sludge dewatering. aiming to reduce the ammonium nitrogen load. introduced to the biological part of the treatment plant.
引用
收藏
页码:1445 / 1460
页数:16
相关论文
共 50 条
  • [41] Coagulant selection and sludge conditioning in a slaughterhouse wastewater treatment plant
    Al-Mutairi, NZ
    Hamoda, MF
    Al-Ghusain, I
    [J]. BIORESOURCE TECHNOLOGY, 2004, 95 (02) : 115 - 119
  • [42] Modelling and calibration of a conventional activated sludge wastewater treatment plant
    Birs, Isabela R.
    Nascu, Ioana
    Darab, Cosmin
    Nascu, Ioan
    [J]. PROCEEDING OF 2016 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR), 2016, : 257 - 262
  • [43] Characterization of Wastewater in an Activated Sludge Treatment Plant of the Food Sector
    Yáñez-Hernández, Oscar
    Ríos-Lira, Armando Javier
    Pantoja-Pacheco, Yaquelin Verenice
    Ruelas-Santoyo, Edgar Augusto
    Asato-España, Martha Laura
    Valdovinos-García, Esveidi Montserrat
    [J]. Water (Switzerland), 2024, 16 (18)
  • [44] Microbial characteristic of anoxic sludge in produced wastewater treatment plant
    Liu, Ruyin
    Min, Yang
    Gao, Yingxin
    Li, Dong
    Hesham, Abd El-Latif
    [J]. JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S483 - S484
  • [45] SLUDGE HANDLING AT GRAND RAPIDS MICHIGAN WASTEWATER TREATMENT PLANT
    VOSHEL, D
    [J]. JOURNAL WATER POLLUTION CONTROL FEDERATION, 1966, 38 (09): : 1506 - &
  • [46] Sludge reduction by lumbriculus variegatusin Ahvas wastewater treatment plant
    Yalda Basim
    Mahdi Farzadkia
    Nematollah Jaafarzadeh
    Tim Hendrickx
    [J]. Iranian Journal of Environmental Health Science & Engineering, 9
  • [47] Hierarchical fuzzy control of an activated sludge wastewater treatment plant
    Sanchez, EN
    Beteau, JF
    Vera, G
    Cadet, C
    [J]. PROCEEDINGS OF THE 2003 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2003, : 1836 - 1841
  • [48] SLUDGE THICKENING FACILITY METROPOLITAN WASTEWATER TREATMENT-PLANT
    不详
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1981, 26 (05): : 108 - 113
  • [49] PROCESSING OF SEWAGE SLUDGE WITH ENERGY RECOVERY IN A WASTEWATER TREATMENT PLANT
    Sadecka, Zofia
    Weiss, Elzbieta
    Myszograj, Sylwia
    [J]. ENVIRONMENT PROTECTION ENGINEERING, 2012, 38 (03): : 97 - 105
  • [50] Sludge thickening in a wastewater treatment plant using a modified hydrocyclone
    Senfter, Thomas
    Fritsch, Lukas
    Berger, Manuel
    Kofler, Tobias
    Mayerl, Christian
    Pillei, Martin
    Kraxner, Michael
    [J]. CARBON RESOURCES CONVERSION, 2021, 4 : 132 - 141