Mechanical properties of cast half-grouted sleeve splice with rebar bonding defects

被引:4
|
作者
Che, Wenpeng [1 ,2 ]
Chen, Jianwei [2 ]
Liu, Ziye [2 ]
Tian, Wenling [1 ]
机构
[1] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin, Peoples R China
[2] North China Univ Sci & Technol, Coll Civil & Architectural Engn, Bohai Rd, Caofeidian Xincheng 063210, Tangshan, Peoples R China
基金
美国国家科学基金会;
关键词
half-grouted sleeve; bonding defects; strip off ribs; mortar coatings; rebar diameter; failure mode; PIPE SPLICE; BEHAVIOR; CONNECTIONS;
D O I
10.1177/13694332221107743
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes an experimental study on the mechanical properties of cast half-grouted sleeve splice with rebar bonding defects, i.e. strip off ribs or mortar coatings of connecting rebar, which may lead to inadequate cohesiveness between the rebar and grout. A total of 12 groups of specimens were tested to study the effects of bonding defects on the bearing capacity, failure modes, and strain distribution of the grouted sleeve splice. The strip off rib length-to-embedded length ratios (0.3, 0.5, and 1), the proportion of mortar coating surface area along the embedded length (0.5 and 1), and the rebar diameter (12 mm and 20 mm) were investigated. The test results show that the failure modes of the specimens can be divided into rebar tensile failure and rebar bond slip failure. The load-displacement responses of the specimens occurring due to rebar failure were similar. Moreover, the bond strength between the rebar and grout decreased significantly, while the strip off rib length increased. When the strip off rib length coefficient reached 100%, compared with a specimen with no defects, the average tensile capacity of the sleeves splice of 12 mm and 20 mm diameter rebars were decreased by 26.5% and 58.3%, respectively. The mortar coating had no significant effect on the connection performance of the specimens. To evaluate the performance of the specimens, based on the experimental data, simple ratios comprising the yield, strength, ductility and capacity ratios were discussed and proposed.
引用
收藏
页码:2870 / 2884
页数:15
相关论文
共 50 条
  • [21] Uniaxial tensile behavior of half-grouted sleeve connections with concrete cover after exposure to elevated temperatures
    Liu, Yanchun
    Peng, Tingting
    Miao, Jijun
    Liu, Caiwei
    Ba, Guangzhong
    Zhao, Yuliang
    Xiao, Jianzhuang
    Hou, Dongshuai
    Liu, Yuanlin
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [22] Numerical study on the influence of defects in grouting on the mechanical properties of a full grouted sleeve connector
    Kahama, Espoir Kulondwa
    Fuzhe, Xie
    Anglaaere, Desmond-Luke M.
    JOURNAL OF ADHESION, 2022, 98 (16): : 2550 - 2581
  • [23] Experimental Study on the Effect of Grouting Defects on Mechanical Properties of the Rebar Connected by Full-Grouted Sleeves
    Guo, Fei
    Li, Junhua
    He, Sicong
    Zhou, Chunheng
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022
  • [24] Computational and Experimental Mechanical Modelling of a Composite Grouted Splice Sleeve Connector System
    Kuang, Zhiping
    Zheng, Guanyu
    MATERIALS, 2018, 11 (02):
  • [25] Bond strength prediction model of defective grout materials in half-grouted sleeve connections under uniaxial and cyclic loadings
    Liu, Qizhou
    Lin, Yuhan
    Li, Jinzhou
    Yang, Chengjian
    Chen, Jingyi
    Zhang, Min
    Liu, Bing
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 352
  • [26] Seismic performance of precast segmental piers with a novel combined half-grouted sleeve-socket (HGS-S) connection
    Xu, Wenjing
    Gu, Minjie
    Chen, Xu
    Li, Jianzhong
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 175
  • [27] Study on Uniaxial Tensile Test of Half Grouted Sleeve Connection with Axial Eccentric Rebar after High Temperature
    Zhang W.
    Wang J.
    Zhao X.
    Li J.
    Lu L.
    Cao Y.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (09): : 9 - 19
  • [28] Post-fire mechanical properties of full-grouted sleeve connection with different grouting defects
    Chen, Dong
    Peng, Songsong
    Hui, Yating
    Tam, Vivian W. Y.
    Wang, Weichen
    Li, Lei
    Cheng, Baoquan
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 21
  • [29] Mechanical behavior of corrugated grouted sleeve splice for precast concrete structures under cyclic loading
    Wei, Muwang
    Peng, Yukang
    Li, Huawei
    Xiao, Boren
    ADVANCES IN CONCRETE CONSTRUCTION, 2025, 19 (01) : 31 - 42
  • [30] Experimental study on mechanical behavior of thermally damaged grouted sleeve splice under cyclic loading
    Xiao, Jianzhuang
    Liu, Lianglin
    Ding, Tao
    Xie, Qinghai
    STRUCTURAL CONCRETE, 2020, 21 (06) : 2494 - 2514