Fabrication and Characterization of Planar Screen-Printed Ag/AgCl Reference Electrode for Disposable Sensor Strip

被引:17
|
作者
Idegami, Koutarou [1 ]
Chikae, Miyuki [2 ]
Nagatani, Naoki [3 ]
Tamiya, Eiichi [4 ]
Takamura, Yuzuru [2 ]
机构
[1] Ishikawa Sunrise Ind Creat Org, Kanazawa, Ishikawa 9208203, Japan
[2] Japan Adv Inst Sci & Technol, Sch Mat Sci, Nomi, Ishikawa 9231292, Japan
[3] Okayama Univ Sci, Dept Appl Chem, Grad Sch Engn, Kita Ku, Okayama 7000005, Japan
[4] Osaka Univ, Grad Sch Engn, Dept Appl Phys, Suita, Osaka 5650871, Japan
关键词
STATE REFERENCE ELECTRODE; GOLD NANOPARTICLE; LIQUID-JUNCTION; ELECTROCHEMICAL DETECTION; CARBON ELECTRODE; LAYER; CHIP; ELECTROANALYSIS; IMPROVEMENT; TECHNOLOGY;
D O I
10.1143/JJAP.49.097003
中图分类号
O59 [应用物理学];
学科分类号
摘要
An accurate disposable planar Ag/AgCl reference electrode with an internal electrolyte was successfully fabricated by the screen-printing process. The internal electrolyte layer was also printed by using an electrolyte paste of sodium alginate containing KCl. The potential stability of the electrode was investigated at different operation times and Cl(-) concentrations in test solutions. Results show that the electrode has long-term potential stability (approximately 60 min), and that its performance does not depend on the Cl(-) concentration. This electrode can be used to provide various promising applications in sensing techniques based on disposable strips for sensing purposes. (C) 2010 The Japan Society of Applied Physics
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Fabrication of a novel screen-printed carbon electrode based disposable sensor for sensitive determination of an endocrine disruptor BPSIP in environmental and biological matrices
    Singh, Ankit Kumar
    Agrahari, Shreanshi
    Gautam, Ravindra Kumar
    Tiwari, Ida
    [J]. MICROCHEMICAL JOURNAL, 2023, 193
  • [22] Voltammetric characterization of a N,N′-diphenyl-p-phenylenediamine-loaded screen-printed electrode:: A disposable sensor for hydrogen sulfide
    Lawrence, NS
    Jiang, L
    Jones, TGJ
    Compton, RG
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2054 - 2059
  • [23] Disposable nitrite sensor based on hemoglobin-colloidal gold nanoparticle modified screen-printed electrode
    Xu, XX
    Liu, SQ
    Li, B
    Ju, HX
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2427 - 2442
  • [24] Solid-state sodium-selective sensors based on screen-printed Ag/AgCl reference electrodes
    Walsh, S
    Diamond, D
    McLaughlin, J
    McAdams, E
    Woolfson, D
    Jones, D
    Bonner, M
    [J]. ELECTROANALYSIS, 1997, 9 (17) : 1318 - 1324
  • [25] Planar Ag/AgCl Reference Electrode for Electrochemical Agronomic Sensors
    Mamilla, Sreenivasulu
    Yousuf, Shah Zahid
    Avulapati, Madan Mohan
    Ahmed-Al Mallahi
    Murty, N. V. L. Narasimha
    [J]. IEEE SENSORS LETTERS, 2024, 8 (07)
  • [27] Disposable screen-printed enzyme sensor for simultaneous determination of starch and glucose
    Hu, T
    Zhang, XE
    Zhang, ZP
    [J]. BIOTECHNOLOGY TECHNIQUES, 1999, 13 (06) : 359 - 362
  • [28] Electrochemical Sensors with Screen Printed Ag|AgCl|KCl Reference Electrodes
    Manjakkal, Libu
    Pascual, Carles Llavina
    Dahiya, Ravinder
    [J]. 2017 IEEE SENSORS, 2017, : 504 - 506
  • [29] The fabrication and performance of an Ag/AgCl reference electrode in human serum
    Yu, PG
    Dong, SJ
    [J]. ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 167 - 174
  • [30] Disposable photoelectrochemical sensing strip for highly sensitive determination of perfluorooctane sulfonyl fluoride on functionalized screen-printed carbon electrode
    Li, Xin
    Wang, Xinlei
    Fang, Tian
    Zhang, Lizhi
    Gong, Jingming
    [J]. TALANTA, 2018, 181 : 147 - 153