Measurement of pork freshness using potentiometric sensor

被引:25
|
作者
Kaneki, N
Miura, T
Shimada, K
Tanaka, H
Ito, S
Hotori, K
Akasaka, C
Ohkubo, S
Asano, Y
机构
[1] Muroran Inst Technol, Satellite Venture Business Lab, Muroran, Hokkaido 0508585, Japan
[2] Muroran Inst Technol, Dept Comp Sci & Syst Engn, Muroran, Hokkaido 0508585, Japan
[3] TOA DKK Co, Sayama, Saitama 3501388, Japan
[4] Muroran Inst Technol, Dept Appl Chem, Muroran, Hokkaido 0508585, Japan
[5] Hachinohe Inst Technol, Dept Chem & Biol Engn, Hachinohe, Aomori 0391192, Japan
关键词
potentiometric sensor; pork freshness; multiple regression analysis; principal component analysis;
D O I
10.1016/j.talanta.2003.07.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study evaluated pork freshness using potentiometric solid-state electrodes in order to detect chemical indices such as reduced compounds, organic compounds and sulfides, which are produced during the initial stage of putrefaction in meat. Pt, CuS and Ag2S electrodes selected as solid-state electrodes have, respectively, been used to detect the organic compounds (regarded as chemical indices of deterioration in meat freshness). The outputs of these electrode,; have been analyzed by principal component analysis (PCA) and multiple regression analysis (MRA) in order to find the correlation with the results of viable bacteria] counts. By using the potentiometric sensor, the pork freshness was evaluated and the PCA and MRA corresponded to the degree of bacterial increases more simply and rapidly than other methods such as viable bacterial counts or a biosensor. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 50 条
  • [41] Potentiometric sensor for the measurement of Cd2+ transport in yeast and plants
    Plaza, S
    Szigeti, Z
    Geisler, M
    Martinoia, E
    Aeschlimann, B
    Günther, D
    Pretsch, E
    ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) : 10 - 16
  • [42] Sensor reveals steak freshness
    Wheeler, MD
    PHOTONICS SPECTRA, 1997, 31 (10) : 38 - 38
  • [43] DEVELOPMENT OF A FISH FRESHNESS SENSOR
    LUONG, JHT
    MALE, KB
    NGUYEN, AL
    AMERICAN BIOTECHNOLOGY LABORATORY, 1988, 6 (08): : 38 - 41
  • [44] POTENTIOMETRIC SENSOR USING STABILIZED ZIRCONIA FOR CHLORINE GAS
    YAN, YT
    MIURA, N
    YAMAZOE, N
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 287 - 290
  • [45] A NEW COLORIMETRIC MEASUREMENT OF FISH FRESHNESS USING NUCLEOSIDE OXIDASE
    ISONO, Y
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1990, 54 (11): : 2827 - 2832
  • [46] TITRATION OF ANIONIC SURFACTANTS USING A NEW POTENTIOMETRIC SENSOR
    ZELENKA, L
    SAKBOSNAR, M
    MAREK, N
    KOVACS, B
    ANALYTICAL LETTERS, 1989, 22 (13-14) : 2791 - 2802
  • [47] Zirconia potentiometric oxygen sensor activation using NEMCA
    Shuk, Pavel
    Jantzt, Robert
    INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2014, 7 (05):
  • [48] Pork freshness Pattern Recognition Based on SOM Neural Network
    Guo Peiyuan
    Bi Song
    Yuan Fang
    PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 2338 - 2341
  • [49] Freshness Identification of Iberico Pork Based on Improved Residual Network
    Jiao J.
    Wang W.
    Hou J.
    Sun P.
    He Y.
    Gu L.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2019, 50 (08): : 364 - 371
  • [50] Pork Freshness Spectral Feature Index: Development and Sensitivity Analysis
    Huang Chang-ping
    Zhu Xin-ran
    Zhang Chen-lu
    Qiao Na
    Hu Shun-shi
    Zhang Li-fu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (02) : 552 - 558