Using of HPLC coupled with coulometric detector for the determination of biotin in pharmaceuticals

被引:11
|
作者
Zerzanova, A. [1 ]
Zizkovsky, V. [1 ]
Kucera, R. [1 ]
Klimes, J. [1 ]
Jesensky, I. [1 ]
Dohnal, J. [2 ]
Barron, D. [3 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Pharmaceut Chem & Drug Control, Hradec Kralove 50005, Czech Republic
[2] Zentiva AS, Prague 10237 10, Czech Republic
[3] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
biotin; coulometry; electrochemical detection; HPLC; pharmaceutical preparations;
D O I
10.1016/j.jpba.2007.08.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The method for the determination of biotin by high performance liquid chromatography (HPLC) coupled with coulometric detector is presented here. Chromatographic and detection conditions were tested. A LiChrospher 60RP-select B column (250 mm x 4 mm; 5 mu m) and the mobile phase containing 0.24 mol/L aqueous solution of acetic acid and acetonitrile in the ratio 85:15 (v/v) were found as the most suitable. The flow rate was 1 mL/min and the injected volume of the sample was 20 mu L. The hydrodynamic voltammograrn of biotin was measured and according to obtained data the detection parameters were set - channel I 600 mV, channel II 900 mV, sensitivity 1 mu A. The developed method has been validated. The calibration curve is linear in the range 15-3600 ng/mL, correlation coefficient is 0.9998, limits of detection and quantification are 5 and 15 ng/mL, respectively. Recovery of the spiked samples was 98.67% with R.S.D. 0.255% on average. The developed method has been successfully applied for determination of biotin in pharmaceutical preparations. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 50 条
  • [31] Carotenoid determination in biological microsamples using liquid chromatography with a coulometric electrochemical array detector.
    Ferruzzi, MG
    Sander, LC
    Rock, CL
    Schwartz, SJ
    FASEB JOURNAL, 1998, 12 (05): : A967 - A967
  • [32] RAPID-DETERMINATION OF TYRAMINE IN FISH FEED AND SLAUGHTER OFFAL BY HPLC USING COULOMETRIC DETECTION
    VUORELA, H
    HINKKANEN, R
    HILTUNEN, R
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1989, 189 (05): : 434 - 437
  • [33] Determination of biotin in pharmaceutical preparation by means of HPLC and/or MEKC
    Gadzala-Kopciuch, R
    Szumski, M
    Buszewski, B
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (02) : 195 - 205
  • [34] Determination of the biotin content of select foods using accurate and sensitive HPLC/avidin binding
    Staggs, CG
    Sealey, WM
    McCabe, BJ
    Teague, AM
    Mock, DM
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2004, 17 (06) : 767 - 776
  • [35] HPLC-fluorescence determination of unconjugated estrogens in pharmaceuticals
    Gatti, R
    Gioia, MG
    Di Pietra, AM
    Cavrini, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) : 187 - 192
  • [36] HPLC determination of warfarin and acenocoumarol in raw materials and pharmaceuticals
    De Orsi, D
    Gagliardi, L
    Turchetto, L
    Tonelli, D
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) : 891 - 895
  • [37] HPLC-fluorescence determination of chlorocresol and chloroxylenol in pharmaceuticals
    Gatti, R
    Roveri, P
    Bonazzi, D
    Cavrini, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (03) : 405 - 412
  • [38] Determination of azithromycin in raw materials and pharmaceutical formulations by HPLC coupled with an evaporative light scattering detector
    Zeng, Aiguo
    Liu, Xia
    Zhang, Siruo
    Zheng, Yan
    Huang, Ping
    Du, Kangli
    Fu, Qiang
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 9 (02) : 107 - 116
  • [39] Sensitive Determination of Saponins in Radix et Rhizoma Notoginseng by Charged Aerosol Detector Coupled with HPLC
    Bai, Chang-Cai
    Han, Shu-Yan
    Chai, Xing-Yun
    Jiang, Yong
    Li, Ping
    Tu, Peng-Fei
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (02) : 242 - 260
  • [40] Rapid and sensitive determination of enzyme kinetics of drug metabolism using HPLC coupled with a stop-flow radioactivity flow detector
    Zhao, WP
    Wang, LF
    Zhang, DL
    Zhu, MS
    DRUG METABOLISM REVIEWS, 2004, 36 : 257 - 257