Using of HPLC coupled with coulometric detector for the determination of biotin in pharmaceuticals

被引:11
|
作者
Zerzanova, A. [1 ]
Zizkovsky, V. [1 ]
Kucera, R. [1 ]
Klimes, J. [1 ]
Jesensky, I. [1 ]
Dohnal, J. [2 ]
Barron, D. [3 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Pharmaceut Chem & Drug Control, Hradec Kralove 50005, Czech Republic
[2] Zentiva AS, Prague 10237 10, Czech Republic
[3] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
biotin; coulometry; electrochemical detection; HPLC; pharmaceutical preparations;
D O I
10.1016/j.jpba.2007.08.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The method for the determination of biotin by high performance liquid chromatography (HPLC) coupled with coulometric detector is presented here. Chromatographic and detection conditions were tested. A LiChrospher 60RP-select B column (250 mm x 4 mm; 5 mu m) and the mobile phase containing 0.24 mol/L aqueous solution of acetic acid and acetonitrile in the ratio 85:15 (v/v) were found as the most suitable. The flow rate was 1 mL/min and the injected volume of the sample was 20 mu L. The hydrodynamic voltammograrn of biotin was measured and according to obtained data the detection parameters were set - channel I 600 mV, channel II 900 mV, sensitivity 1 mu A. The developed method has been validated. The calibration curve is linear in the range 15-3600 ng/mL, correlation coefficient is 0.9998, limits of detection and quantification are 5 and 15 ng/mL, respectively. Recovery of the spiked samples was 98.67% with R.S.D. 0.255% on average. The developed method has been successfully applied for determination of biotin in pharmaceutical preparations. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:730 / 735
页数:6
相关论文
共 50 条
  • [1] HPLC COUPLED WITH A COULOMETRIC ELECTRODE ARRAY DETECTOR - DETERMINATION OF PHLORETIN GLUCOSIDE IN JUICES FOR DETECTION OF ADULTERATION
    SONTAG, G
    BERNWIESER, I
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 1994, 90 (03) : 72 - 74
  • [2] Omeprazole determination using HPLC with coulometric detection
    Sluggett, GW
    Stong, JD
    Adams, JH
    Zhao, Z
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (3-4) : 357 - 361
  • [3] HPLC DETERMINATION OF METHOTREXATE IN SERUM OR PLASMA OPTIMIZED WITH A DUAL COULOMETRIC DETECTOR
    DUTRIEU, J
    DELMOTTE, YA
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 315 (06): : 539 - 542
  • [4] Assessment of coulometric array electrochemical detection coupled with HPLC-UV for the absolute quantitation of pharmaceuticals
    Hicks, Michael B.
    Salituro, Leah
    Mangion, Ian
    Schafer, Wes
    Xiang, Rong
    Gong, Xiaoyi
    Welch, Christopher J.
    ANALYST, 2017, 142 (03) : 525 - 536
  • [5] A COULOMETRIC DETECTOR FOR HPLC AND FIA USING RETICULATED VITREOUS CARBON ELECTRODES
    CURRAN, DJ
    TOUGAS, TP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 186 (AUG): : 146 - ANYL
  • [6] Simultaneous Determination of Amoxicillin, Lansoprazole, and Levofloxacin in Pharmaceuticals by HPLC with UV–Vis Detector
    Mustafa Gülfen
    Yazgı Canbaz
    Abdil Özdemir
    Journal of Analysis and Testing, 2020, 4 : 45 - 53
  • [7] COULOMETRIC DETERMINATION OF MICROGRAM AMOUNTS OF WATER IN SOME PHARMACEUTICALS
    SZYSZKO, E
    GAWRYCH, Z
    ACTA POLONIAE PHARMACEUTICA, 1975, 32 (03): : 333 - 338
  • [8] HPLC Determination of Norepinephrine in Pharmaceuticals
    Brabcova, Ivana
    Satinsky, Dalibor
    Solich, Petr
    CHEMICKE LISTY, 2011, 105 (11): : 864 - 868
  • [9] Simultaneous Determination of Amoxicillin, Lansoprazole, and Levofloxacin in Pharmaceuticals by HPLC with UV-Vis Detector
    Gulfen, Mustafa
    Canbaz, Yazgi
    Ozdemir, Abdil
    JOURNAL OF ANALYSIS AND TESTING, 2020, 4 (01) : 45 - 53
  • [10] Simultaneous Determination of Homovanillic and Vanillylmandelic Acid by HPLC Using a Coulometric Detector with Renewable Glassy Carbon Microbeads Based Working Electrode
    Mika, Jan
    Barek, Jiri
    Zima, Jiri
    Moreira, Josino Costa
    Dejmkova, Hana
    ELECTROANALYSIS, 2018, 30 (07) : 1455 - 1460