共 50 条
Specific detection of avidin-biotin binding using liquid crystal droplets
被引:49
|作者:
Khan, Mashooq
[1
]
Park, Soo-Young
[1
]
机构:
[1] Kyungpook Natl Univ, Sch Appl Chem Engn, Dept Polymer Sci & Engn, Taegu 702701, South Korea
基金:
新加坡国家研究基金会;
关键词:
Biosensor;
Liquid crystal droplet;
Microfluidics;
Biotin;
Avidin;
Selective biosensor;
ORDERING TRANSITIONS;
INTERFACES;
IMMOBILIZATION;
SURFACES;
D O I:
10.1016/j.colsurfb.2015.01.047
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
Poly(acrylicacid-b-4-cynobipheny1-4'-undecylacrylate) (PAA-b-LCP)-functionalized 4-cyano-4'-pentylbiphenyl (5CB) droplets were made by using microfluidic technique. The PAA chains on the 5CB droplets, were biotinylated, and used to specifically detect avidin-biotin binding at the 5CB/aqueous interface. The avidin-biotin binding was characterized by the configurational change (from radial to bipolar) of the 5CB droplets, as observed through a polarized optical microscope. The maximum biotinylation was obtained by injecting a >100 mu g/mL biotin aqueous solution, which enabled a limit of detection of 0.5 mu g/mL avidin. This droplet biosensor could specifically detect avidin against other proteins such as bovine serum albumin, lysozyme, hemoglobin, and chymotrypsinogen solutions. Avidin detection with 5CB(PAA-biotin) droplets having high sensitivity, specificity, and stability demonstrates new applications of the functionalized liquid crystal droplets that can detect specific proteins or other analytes through a ligand/receptor model. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 246