Difference of optimal dose of contrast agent between gray-scale and power Doppler imaging in assessing graded coronary stenosis by myocardial contrast echocardiography

被引:1
|
作者
Masugata, H
DeMaria, AN
Peters, B
Lafitte, S
Strachan, GM
Kwan, OL
Ohmori, K
Mizushige, K
Kohno, M
机构
[1] Kagawa Med Univ, Dept Internal Med 2, Kagawa 7610793, Japan
[2] Univ Calif San Diego, Div Cardiovasc, San Diego, CA 92103 USA
关键词
myocardial contrast echocardiography; myocardial blood flow; perfusion;
D O I
10.1097/01.RLI.0000073641.93901.b9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: In myocardial contrast echocardiography (MCE), power Doppler imaging is more sensitive to contrast agent (microbubble) than gray-scale B-mode imaging; however, no data exist regarding the optimal contrast dose in power Doppler imaging. This study examined the optimal dose of contrast agent for power Doppler in assessing coronary stenosis. Methods: Three grades of coronary stenosis were produced in 6 open-chest dogs. NICE was performed with gray-scale and power Doppler during continuous infusion of 0.2 mL/min FS-069. Thereafter, NICE was repeated with power Doppler during continuous infusion of 0.1 mL/min FS-069. Results: Although the videointensity in the stenosed bed with power Doppler (214+/-14) was greater than gray scale (35+/-17) during 0.2 mL/min FS-069 infusion (P<0.0001), power Doppler failed to identify milder coronary stenoses because videointensity in stenosed bed was quickly saturated with contrast agent. The videointensity in the stenosed bed with power Doppler (127+/-49) during 0.1 mL/min FS-069 infusion was greater than gray scale (35+/-17) during 0.2 mL/min FS-069 infusion (P<0.0001), and all levels of stenosis were identified with power Doppler, even though the dose of contrast agent was half of that of gray scale imaging. The correlation between videointensity and myocardial blood flow was better in the case of power Doppler at 0.1 mL/min FS-069 infusion (r=0.77, P<0.0001) than in the case of gray scale imaging at 0.2 mL/min FS-069 infusion (r=0.66, P<0.01). Conclusions: These data support the need for a lower dose of contrast agent for power Doppler than for gray scale to detect milder coronary stenosis and avoid saturation of imaging fields.
引用
收藏
页码:550 / 558
页数:9
相关论文
共 50 条
  • [31] Quantitative Evaluation of Myocardial Perfusion and Function in a Rabbit Model of Coronary Artery Atherosclerosis by Contrast Echocardiography and Tissue Doppler Imaging
    Zhang, Li
    Xie, Mingxing
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C74 - C74
  • [32] Sonographic detection of acute parenchymal injury in an experimental porcine model of renal hemorrhage: Gray-scale imaging using a sonographic contrast agent
    Schmiedl, UP
    Carter, S
    Martin, RW
    Eubank, W
    Winter, T
    Chang, PP
    Bauer, A
    Crum, LA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) : 1289 - 1294
  • [33] Comparison between myocardial contrast echocardiography and contrast enhanced magnetic resonance imaging in prediction of the myocardial viability after direct percutaneous transluminal coronary angioplasty in acute myocardial infarction
    Seo, H
    Moon, JY
    Ko, YG
    Kang, SM
    Ha, JW
    Rim, SJ
    Jang, YS
    Shim, W
    Cho, SY
    Choe, KO
    Chung, NS
    Choi, YW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 24A - 24A
  • [34] Low-dose adenosine stress real-time myocardial contrast echocardiography can quantitatively evaluate coronary artery stenosis and myocardial perfusion
    Zhou, X.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 : S48 - S48
  • [35] Low-dose Adenosine Stress Real-time Myocardial Contrast Echocardiography can Quantitatively Evaluate Coronary Artery Stenosis and Myocardial Perfusion
    Xiao, Zhou
    Zhi, Guang
    Xu, Yong
    Hou, Haijun
    Yan, Guohui
    CIRCULATION, 2010, 122 (02) : E296 - E296
  • [36] Estimation of coronary artery stenosis by low-dose adenosine stress real-time myocardial contrast echocardiography: a quantitative study
    Zhou Xiao
    Zhi Guang
    Xu Yong
    Wang Jing
    Yan Guo-hui
    CHINESE MEDICAL JOURNAL, 2012, 125 (10) : 1795 - 1798
  • [37] Contrast echocardiography with Harmonic Power Doppler Imaging in myocardial perfusion assessment after recent acute myocardial infarction and primary PTCA: comparison with SPECT
    Santoro, F
    Picozzi, A
    Casucci, R
    Braga, SS
    Pedretti, RFE
    EUROPEAN HEART JOURNAL, 2000, 21 : 235 - 235
  • [38] Comparison between contrast echocardiography and magnetic resonance imaging to predict improvement of myocardial function after primary coronary intervention
    Biagini, E
    van Geuns, RJ
    Baks, T
    Boersma, E
    Rizzello, V
    Galema, TW
    de Feyter, PJ
    ten Cate, FJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (03): : 361 - 366
  • [39] Detection of viable myocardium by transvenous myocardial contrast echocardiography using harmonic power Doppler - Canine model of acute coronary occlusion and reperfusion
    Teupe, C
    Takeuchi, M
    Yao, JF
    Avelar, E
    Pandian, N
    CHEST, 2001, 120 (02) : 567 - 572
  • [40] Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent
    Firschke, C
    Lindner, JR
    Wei, K
    Goodman, NC
    Skyba, DM
    Kaul, S
    CIRCULATION, 1997, 96 (03) : 959 - 967