Technical errors in the application of Graf's hip sonography method.

被引:7
|
作者
Müller, W
Lercher, K
DeVaney, TTJ
Giner, F
Graf, R
机构
[1] Inst Med Phys & Biophys, A-8010 Graz, Austria
[2] Allgemeines & Orthopad Landeskrankenhaus, Stolzalpe, Austria
来源
ULTRASCHALL IN DER MEDIZIN | 2001年 / 22卷 / 01期
关键词
infant hip sonography; hip screening; developmental dysplasia of the hip (DDH); CDH; artefacts;
D O I
10.1055/s-2001-11250
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: The aim of the study is to point out possible examination errors because of a titled transducer, and to analyse their sources. Methods: The results obtained by experienced examiners using the correct examination technique were compared to results obtained under defined deviations from the standard. With the use of a computer model the course taken by the ultrasound waves in the neonatal hip was simulated and the sonographic image reconstructed. Results: Twisted as well as tilted positions of the transducer lead to significant errors in ct, the acetabular roof angle. This is in accordance with the computer model predictions. Caudo-cranially tilted probes lead to false-positive, therapeutically relevant incorrect diagnoses. Conclusion: The computer simulation predicts a high degree of accuracy of hip sonography in Graf's technique under standard conditions. The effectiveness of sonographic infant hip screening largely depends on the ability to adhere to the standardized approach, minimizing possible errors. A mechanical transducer guide prevents tilting errors by reducing the degrees of variability in positioning the transducer.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 50 条
  • [1] Commission Hip Sonography according to Graf
    Dubs, Beat
    ULTRASCHALL IN DER MEDIZIN, 2016, 37 (05):
  • [2] Commission of hip sonography after Graf
    Dubs, Beat
    ULTRASCHALL IN DER MEDIZIN, 2013, 34 (01): : 101 - 101
  • [3] Commission Hip Sonography according to Graf
    Braun, Luciano
    ULTRASCHALL IN DER MEDIZIN, 2016, 37 (04): : 431 - 431
  • [4] Commission Hip-Sonography according to Graf
    Dubs, Beat
    ULTRASCHALL IN DER MEDIZIN, 2013, 34 (04):
  • [5] Schmeling method. Errors in conclusion and application
    Rumyantsev, AV
    ZHURNAL OBSHCHEI KHIMII, 1995, 65 (11): : 1766 - 1772
  • [6] TECHNICAL ASPECTS OF FETAL HIP SONOGRAPHY
    WAGNER, UA
    GEMBRUCH, U
    SCHMITT, O
    HANSMANN, M
    ULTRASCHALL IN DER MEDIZIN, 1994, 15 (01): : 33 - 37
  • [7] Hip sonography according to Graf: practical notes for the student, the examiner and the reviewer
    Chlapoutakis, Konstantinos
    Maizen, Claudia
    Placzek, Sonja
    O'Beirne, Joseph
    Dubs, Beat
    Casini, Carolina
    Tzatzairis, Themistoklis
    MEDICAL ULTRASONOGRAPHY, 2023, 25 (04) : 453 - 465
  • [8] Difference in the Clinical Outcome of the Graf's and Harcke's Ultrasound Hip Screening Method
    Romsauerova, A.
    Sanjay, S.
    SCOTTISH MEDICAL JOURNAL, 2009, 54 (03) : 55 - 55
  • [9] Tables for the application of Mr Innes's method.
    Robbins, F
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1906, 67 (01) : 0444 - 0447
  • [10] IS SONOGRAPHY OF THE HIP A SENSIBLE SCREENING METHOD
    BENZBOHM, G
    WIDEMANN, B
    HERRMANN, F
    WEIDTMAN, V
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1987, 146 (02): : 188 - 191