ENDOCOM: Implantable wireless pressure sensor for the follow-up of abdominal aortic aneurysm stented

被引:4
|
作者
Menudet, J. -F.
机构
[1] Univ Paris 06, UMR7606, SoC-SYEL, F-75005 Paris, France
[2] Univ Paris 06, UMR 7190, F-75252 Paris 05, France
[3] REO, Team Rocquencourt, INRIA, F-78153 Le Chesnay, France
[4] UMR 6594, Technopole de Chateau Gombert, F-13451 Marseille 13, France
[5] UMR 6600, F-60205 Compiegne, France
[6] Grp Hosp Pitie Salpetriere, F-75013 Paris, France
关键词
RFID pressure sensor; Numerical modelling; AAA; in vivo experiments; ENDOVASCULAR REPAIR; ENDOTENSION; RUPTURE;
D O I
10.1016/j.irbm.2011.01.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An abdominal aortic aneurysm (AAA) is a dilatation of the aorta at the abdominal level, the rupture of which is a life threatening complication with an 80% mortality rate. Even though those devices keep improving, the failure rate of the endovascular treatment is due to persisting pressure into the excluded aneurysmal sac. Since 2005, several integrated sensors have been designed for the follow-up of the AAA treated by a stent. Solutions are based on the use of a single sensor. Thrombus in the excluded AAA can modify the field of pressure when leaks appeared and a network of sensors should be used. We present in this paper the ENDOCOM project that aims to design an implantable pressure sensor that can be used in a network configuration. To validate the new materials, we developed a framework composed of in vitro experiments and in vivo tests on large animal model. Numerical modeling has been investigated from the experimental data to determine the optimal position of sensor. Some results of those different parts are shown in this paper. (C) 2011 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 50 条
  • [1] ENDOCOM: A WIRELESS ENDOPROSTHESIS DEDICATED TO THE FOLLOW-UP OF ABDOMINAL AORTIC ANEURYSMS
    Mazeyrat, J.
    Romain, O.
    Lautru, D.
    Wong, M. F.
    Berthier, B.
    Lagree, P. Y.
    Gerbeau, J. F.
    Deplano, V.
    Leprince, P.
    Bonneau, M.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (07): : 411 - 411
  • [2] Abdominal Aortic Aneurysm: lifelong Follow-up
    Goltz, J. P.
    GEFASSCHIRURGIE, 2019, 24 (04): : 286 - 286
  • [3] Telemedicine for screening and follow-up of abdominal aortic aneurysm
    Sterpetti, Antonio V.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1497 - 1497
  • [4] Abdominal Aortic aneurysm screening and Follow-up after EVAR
    不详
    GEFASSCHIRURGIE, 2012, 17 (03): : 170 - 170
  • [5] Follow-up imaging experience with endovascular abdominal aortic aneurysm stents
    Khan, AM
    Jafri, SZ
    Khan, S
    Salem, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 125 - 125
  • [6] ENDOCOM:: Abdominal aortic aneurysm test bench for in vitro simulation
    Mazeyrat, Johan
    Romain, Olivier
    Garda, Patrick
    Lagree, Pierre-Yves
    Destrade, Michel
    Karouia, Mourad
    Leprince, Pascal
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2323 - +
  • [7] Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair
    Wever, JJ
    Blankensteijn, JD
    Mali, WPTM
    Eikelboom, BC
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (02) : 177 - 182
  • [8] Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures
    Sun, Zhong-Hua
    JOURNAL OF GERIATRIC CARDIOLOGY, 2012, 9 (01) : 49 - 60
  • [9] Endovascular Abdominal Aortic Aneurysm Repair: Nonenhanced Volumetric CT for Follow-up
    Bley, Thorsten A.
    Chase, Peter J.
    Reeder, Scott B.
    Francois, Christopher J.
    Shinki, Kazuhiko
    Tefera, Girma
    Ranallo, Frank N.
    Grist, Thomas M.
    Pozniak, Myron
    RADIOLOGY, 2009, 253 (01) : 253 - 262
  • [10] BALLISTOCARDIOGRAM IN ABDOMINAL AORTIC ANEURYSM - FOLLOW-UP ON CASE PRESENTED AT THE SPRING MEETING
    STARR, I
    AMERICAN JOURNAL OF CARDIOLOGY, 1958, 1 (04): : 530 - 530