Closure of the femoral artery after cardiac catheterization: A comparison of Angio-Seal, StarClose, and manual compression

被引:78
|
作者
Deuling, J. H. H. [1 ]
Vermeulen, R. P. [1 ]
Anthonio, R. A. [1 ]
van den Heuvel, A. F. M. [1 ]
Jaarsma, T. [1 ]
Jessurun, G. [1 ]
de Smet, B. J. G. L. [1 ]
Tan, E. S. [1 ]
Zijistra, F. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Thorax, Dept Cardiol, NL-9700 RB Groningen, Netherlands
关键词
closure devices; Angio-Seal; StarClose; complications;
D O I
10.1002/ccd.21429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare Angio-Seal (AS) and StarClose (SC) and manual compression (MC) on efficacy of hemostasis, complication rate, safety of early mobilization, and patient comfort. Background: Closure of the femoral artery after cardiac catheterization can be obtained through different methods. Today, physicians can choose from a number of different devices to achieve arterial closure. Methods: In a prospective trial 450 patients were randomized to AS, SC, or MC. Patients were mobilized 1 to 2 hr after device placement, and 6 hr after MC. Data were collected during hospital admission and by telephone at one month after hospital discharge. Results: Devices were used in 138/150 allocated to AS and 124/150 allocated to SC patients (92% vs. 83%, P = 0.015) Patients with MC experienced more pain during sheath removal than patients receiving a device, and rated their period of bed rest as less comfortable. Oozing and need for pressure bandage at the puncture site were observed in 37 AS patients and 57 SC patients (25% vs. 38%, P = 0.002). Hematoma occurred in 15 AS patients, in 17 SC patients, and in 14 MC patients (11 vs. 14 vs. 9%, Ins). Conclusion: There is no difference in safety between the three methods of arterial closure. SC was more often not used or successfully deployed. SC patients more often had continuing oozing. On patient comfort, closure devices performed better than MC. Early ambulation in patients with a closure device is safe. AS is the preferred method of arterial closure after cardiac catheterization. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:518 / 523
页数:6
相关论文
共 50 条
  • [31] In vivo intravascular ultrasound analysis of the absorption rate of the Angio-Seal™ vascular closure device in the porcine femoral artery
    Tellez, Armando
    Cheng, Yanping
    Yi, Geng-Hua
    Conditt, Gerard B.
    McGregor, Jennifer C.
    Flynn, Alyssa M.
    Ordanes, Diane
    Mintz, Gary S.
    Kaluza, Greg L.
    Granada, Juan F.
    EUROINTERVENTION, 2010, 5 (06) : 731 - 736
  • [32] Histologic and duplex comparison of the perclose and Angio-Seal percutaneous closure devices
    Gargiulo, Nicholas J., III
    Veith, Frank J.
    Ohki, Takao
    Scher, Lawrence A.
    Berdejo, George L.
    Lipsitz, Evan C.
    Menegus, Mark
    Greenberg, Mark
    VASCULAR, 2007, 15 (01) : 24 - 29
  • [33] COMPARISON OF HEMOSTASIS TIME AND VASCULAR COMPLICATIONS BETWEEN THE ANGIO-SEAL HEMOSTATIC PUNCTURE CLOSURE DEVICE AND MANUAL PRESSURE
    CONDON, JV
    ELSNER, GB
    NOOTENS, MT
    GOWAN, SA
    COVERDALE, J
    LINNEMEIER, TJ
    ROTHBAUM, DA
    CIRCULATION, 1995, 92 (08) : 2867 - 2867
  • [34] Is immediate ambulation after closure of the femoral artery with the new angio seal device safe?
    Osterwalder, R
    Zutter, A
    Gutmann, M
    Kaiser, C
    Buser, P
    Pfisterer, M
    EUROPEAN HEART JOURNAL, 2004, 25 : 315 - 316
  • [35] The Angio-Seal™ femoral closure device allows immediate ambulation after coronary angiography and percutaneous coronary intervention
    Hvelplund, Anders
    Jeger, Raban
    Osterwalder, Remo
    Bredahl, Majken
    Madsen, Jan Kyst
    Jensen, Jan Skov
    Kaiser, Christoph
    Pfisterer, Matthias
    Galatius, Soren
    EUROINTERVENTION, 2011, 7 (02) : 234 - 241
  • [36] Transaneurysmal Occlusion of Complicated Common Femoral Artery Pseudoaneurysms Using the Angio-Seal Closure Device-A Promising Technique
    Auer, Timo A.
    Fehrenbach, Uli
    Torsello, Giovanni F.
    Collettini, Federico
    Wieners, Gero
    Gunther, Rolf W.
    Gebauer, Bernhard
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 46 (02) : 268 - 273
  • [37] A case of intermittent claudication associated with the Angio-Seal™ vascular closure device after carotid artery stenting
    Motooka M.
    Kondo H.
    Tamura T.
    Kaitani K.
    Izumi C.
    Nakagawa Y.
    Cardiovascular Intervention and Therapeutics, 2014, 29 (2) : 177 - 180
  • [38] Prospective in vivo Evaluation of the Absorption Rate of the Angio-Seal Closure Device Using Intravascular Ultrasound in the Porcine Femoral Artery
    Tellez, Armando
    Cheng, Yanping
    Wallace-Bradley, David
    Alviar, Carlos L.
    Gallego, Catalina
    Conditt, Gerard B.
    McGregor, Jennifer C.
    Kaluza, Greg L.
    Granada, Juan F.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 239I - 239I
  • [39] A Novel Method for Achievement of Vascular Closure After Misdeployment of an Angio-Seal™ Device
    Andrew J. Gunn
    Nael E. Saad
    CardioVascular and Interventional Radiology, 2016, 39 : 1222 - 1223
  • [40] CLINIC EFFECT OF ANGIO-SEAL VASCULAR CLOSURE DEVICE AFTER CORONARY INTERVENTION
    Wang Jun-Yuan
    Tang Sheng-Xing
    Zhu Zheng-Cai
    Xia Chao-Hong
    Ke Yong-Sheng
    Cao Heng
    HEART, 2011, 97 : A167 - A167