Closure of the femoral artery after cardiac catheterization: A comparison of Angio-Seal, StarClose, and manual compression

被引:78
|
作者
Deuling, J. H. H. [1 ]
Vermeulen, R. P. [1 ]
Anthonio, R. A. [1 ]
van den Heuvel, A. F. M. [1 ]
Jaarsma, T. [1 ]
Jessurun, G. [1 ]
de Smet, B. J. G. L. [1 ]
Tan, E. S. [1 ]
Zijistra, F. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Ctr Thorax, Dept Cardiol, NL-9700 RB Groningen, Netherlands
关键词
closure devices; Angio-Seal; StarClose; complications;
D O I
10.1002/ccd.21429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To compare Angio-Seal (AS) and StarClose (SC) and manual compression (MC) on efficacy of hemostasis, complication rate, safety of early mobilization, and patient comfort. Background: Closure of the femoral artery after cardiac catheterization can be obtained through different methods. Today, physicians can choose from a number of different devices to achieve arterial closure. Methods: In a prospective trial 450 patients were randomized to AS, SC, or MC. Patients were mobilized 1 to 2 hr after device placement, and 6 hr after MC. Data were collected during hospital admission and by telephone at one month after hospital discharge. Results: Devices were used in 138/150 allocated to AS and 124/150 allocated to SC patients (92% vs. 83%, P = 0.015) Patients with MC experienced more pain during sheath removal than patients receiving a device, and rated their period of bed rest as less comfortable. Oozing and need for pressure bandage at the puncture site were observed in 37 AS patients and 57 SC patients (25% vs. 38%, P = 0.002). Hematoma occurred in 15 AS patients, in 17 SC patients, and in 14 MC patients (11 vs. 14 vs. 9%, Ins). Conclusion: There is no difference in safety between the three methods of arterial closure. SC was more often not used or successfully deployed. SC patients more often had continuing oozing. On patient comfort, closure devices performed better than MC. Early ambulation in patients with a closure device is safe. AS is the preferred method of arterial closure after cardiac catheterization. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:518 / 523
页数:6
相关论文
共 50 条
  • [1] Closure of the Femoral Artery After Cardiac Catheterization-A Comparison of Angio-Seal, StarClose, and Manual Compression
    Mehta, Sameer K.
    Frutkin, Andrew D.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 586 - 586
  • [2] Rebuttal: Closure of the Femoral Artery After Cardiac Catheterization: Comparing Angio-Seal, StarClose and Manual Compression
    Deuling, J. H. H.
    Vermeulen, R. P.
    van den Heuvel, A. F. M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (04) : 587 - 587
  • [3] Randomized comparison of Angio-seal vs. Starclose for closure of femoral artery access in coronary catheterization
    Lee, Jong-Young
    Kim, Sung Sik
    Yi, Myung-Zoon
    Kim, Sung-Hwan
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Myeong-Ki
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A25 - A25
  • [4] Prospective Nonrandomized Trial of Manual Compression and Angio-Seal and Starclose Arterial Closure Devices in Common Femoral Punctures
    Lakshmi A. Ratnam
    Jowad Raja
    Graham J. Munneke
    Robert A. Morgan
    Anna-Maria Belli
    CardioVascular and Interventional Radiology, 2007, 30 : 182 - 188
  • [5] Prospective nonrandomized trial of manual compression and angio-seal and StarClose arterial closure devices in common femoral punctures
    Chaturvedi, Patanjali
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (04) : 812 - 812
  • [6] Prospective nonrandomized trial of manual compression and Angio-Seal and Starclose arterial closure devices in common femoral punctures
    Ratnam, Lakshmi A.
    Raja, Jowad
    Munneke, Graham J.
    Morgan, Robert A.
    Belli, Anna-Maria
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) : 182 - 188
  • [7] Prospective Nonrandomized Trial of Manual Compression and Angio-Seal and StarClose Arterial Closure Devices in Common Femoral Punctures
    Patanjali Chaturvedi
    CardioVascular and Interventional Radiology, 2007, 30 : 812 - 812
  • [8] Complications with Angio-Seal™ Vascular Closure Devices Compared with Manual Compression after Diagnostic Cardiac Catheterization and Percutaneous Coronary Intervention
    Gregory, Deborah
    Midodzi, William
    Pearce, Neil
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2013, 26 (06) : 630 - 638
  • [9] Hemostatic puncture closure using Angio-Seal™ after diagnostic cardiac catheterization or coronary angioplasty
    Eggebrecht, H
    Haude, M
    Baumgart, D
    Oldenburg, O
    Herrmann, J
    Bruch, C
    Hunold, P
    Neurohr, C
    von Birgelen, C
    Welge, D
    Katz, MA
    Erbel, R
    HERZ, 1999, 24 (08) : 607 - +
  • [10] Percutaneous Transluminal Dilatation of Inadvertent Partial or Complete Occlusion of the Femoral Artery Caused by Angio-Seal™ Deployment for Puncture Site Closure After Cardiac Catheterization
    Brueck, Martin
    Bandorski, Dirk
    Rauber, Klaus
    Boening, Andreas
    JOURNAL OF INVASIVE CARDIOLOGY, 2010, 22 (08): : 353 - 357