MICRO-ELECTRODE FOR COPPER ION DETECTION IN SOLUTION

被引:0
|
作者
Essi, Marc Marie-Maurice Meledge [1 ]
Pradel, A. [2 ]
机构
[1] Univ Cocody, Lab Chim Mat Inorgan, UFR SSMT, Abidjan 22, Cote Ivoire
[2] Univ Montpellier 2, ICGM, CNRS, UMR 5253, F-34095 Montpellier 05, France
来源
CHALCOGENIDE LETTERS | 2011年 / 8卷 / 01期
关键词
Sputtering; Electrolysis; Thin-film; Copper (II) sensor; Electrochemistry; Waste water; THIN-FILM SENSORS; CHALCOGENIDE GLASS; CHEMICAL SENSORS; MEMBRANE; GROWTH; ISE;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Chemical micro-sensor for the detection of Cu2+ ions in solution was prepared. Cu-Ag-S sensing material is build by electrolysis of copper - silver RF sputtered thin film. Analytical behaviour of developed sensor was fully characterised in terms of sensitivity, selectivity and stability. The potentiometric measurements showed a quasi-Nernstian behaviour with a detection limit close to 10(-6) M. In the presence of interfering ions the sensing system is very selective, since low selectivity coefficients are obtained versus various ionic species. The very first measurements carried out in waste waters are presented.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [21] Synchronization of neurons in micro-electrode array cultures
    F. Esposti
    M. G. Signorini
    The European Physical Journal Special Topics, 2008, 165 : 129 - 135
  • [22] MICRO-ELECTRODE PENETRATION OF ASCITES TUMOUR CELLS
    JOHNSTONE, BM
    NATURE, 1959, 183 (4658) : 411 - 411
  • [23] Experimental study of micro-electrode array by micro-WEDM
    School of Mechanical Engineering, Harbin Institute of Technology, Harbin, China
    不详
    Key Eng Mat, (274-278):
  • [24] IMPROVED PCO2 MICRO-ELECTRODE
    PUCACCO, LR
    ANALYTICAL BIOCHEMISTRY, 1978, 90 (01) : 427 - 434
  • [25] MICRO-ELECTRODE STUDIES ON MAMMALIAN VASCULAR MUSCLE
    STEEDMAN, WM
    JOURNAL OF PHYSIOLOGY-LONDON, 1966, 186 (02): : 382 - &
  • [26] MICRO-ELECTRODE ANALYSIS OF THE CORTICAL STRYCHNINE SPIKE
    RAYPORT, M
    JASPER, HH
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1958, 10 (04): : 764 - 764
  • [27] Experimental study of micro-electrode array by micro-WEDM
    Geng, X. S.
    Wang, Y. K.
    Wang, Z. L.
    Shan, D. B.
    MANUFACTURING AUTOMATION TECHNOLOGY DEVELOPMENT, 2011, 455 : 274 - +
  • [28] Micro-Electrode Fabrication Process Using EDM
    Hourmand, M.
    Noordin, M. Y.
    MATERIALS, INDUSTRIAL, AND MANUFACTURING ENGINEERING RESEARCH ADVANCES 1.1, 2014, 845 : 980 - 984
  • [29] MICRO-ELECTRODE FOR ELECTRO-PHYSIOLOGICAL WORK
    WORST, J
    NATURE, 1951, 168 (4278) : 749 - 749
  • [30] Determination of iron ion utilizing poly (p-vinylbenzoylacetone) modified micro-electrode
    Motonaka, J
    Kageyama, S
    Mishima, Y
    Minagawa, K
    Masuda, S
    Ikeda, S
    ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) : 87 - 92