Radiation Calibration for LWIR Hyperspectral imager Spectrometer

被引:0
|
作者
Yang Zhixiong [1 ]
Yu Chunchao [1 ]
Zheng Weijian [1 ]
Lei Zhenggang [1 ]
Yan Min [1 ]
Yuan Xiaochun [1 ]
Zhang Peizhong [1 ]
机构
[1] Kunming Inst Phys, Kunming 650223, Peoples R China
关键词
Hyperspectral imageing Spectrometer; LWIR; linear calibration; blackbody radiation; brightness temperature; RADIOMETRIC CALIBRATION;
D O I
10.1117/12.2071097
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
The radiometric calibration of LWIR Hyperspectral imager Spectrometer is presented. The lab has been developed to LWIR Interferometric Hyperspectral imager Spectrometer Prototype(CHIPED-Iota) to study Lab Radiation Calibration, Two-point linear calibration is carried out for the spectrometer by using blackbody respectively. Firstly, calibration measured relative intensity is converted to the absolute radiation lightness of the object. Then, radiation lightness of the objectis is converted the brightness temperature spectrum by the method of brightness temperature. The result indicated (dagger)that this method of Radiation Calibration calibration was very good.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Calibration, characterization and first results with the ocean PHILLS hyperspectral imager
    Davis, CO
    Kappus, M
    Bowles, J
    Fisher, J
    Antoniades, J
    Carney, M
    IMAGING SPECTROMETRY V, 1999, 3753 : 160 - 168
  • [42] Calibration of VISIR, the VLT mid-infrared imager/spectrometer
    Claret, AJ
    Lagage, PO
    Pantin, E
    Dubreuil, D
    Galdemard, P
    Schoenmaker, A
    Pel, JW
    INSTRUMENT DESIGN AND PERFORMANCE FOR OPTICAL/INFRARED GROUND-BASED TELESCOPES, PTS 1-3, 2003, 4841 : 252 - 262
  • [43] Radiation calibration for Ocean Color CCD Imager
    Ren, JW
    Cui, Y
    Cui, DJ
    EARTH OBSERVING SYSTEMS III, 1998, 3439 : 572 - 577
  • [44] Radiometric calibration of hyperspectral imaging spectrometer based on AOTF
    Xing, Hui
    Zhao, Hui-Jie
    Cheng, Xuan
    Zhang, Ying
    Zhou, Peng-Wei
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2009, 38 (02): : 205 - 209
  • [45] Radiometrie calibration of hyperspectral imaging spectrometer based on AOTF
    Xing, Hui
    Zhao, Hui-Jie
    Cheng, Xuan
    Zhang, Ying
    Zhou, Peng-Wei
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2009, 38 (02): : 205 - 209
  • [46] Characterization and performance of a LWIR polarimetric imager
    Eriksson, Johan
    Bergstrom, David
    Renhorn, Ingmar
    ELECTRO-OPTICAL REMOTE SENSING XI, 2017, 10434
  • [47] Research on Method of Geometry and Spectral Calibration of Pushbroom Dispersive Hyperspectral Imager
    He, Zhiping
    Shu, Rong
    Wang, Jianyu
    MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL REMOTE SENSING TECHNOLOGY, TECHNIQUES AND APPLICATIONS IV, 2012, 8527
  • [48] Laboratory calibration and application of the airborne thermal infrared hyperspectral imager (ATHIS)
    Li C.
    Lv G.
    Yuan L.
    Wang Y.
    Jin J.
    Xu Y.
    Liu C.
    He Z.
    Wang J.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2020, 49 (05):
  • [49] The calibration of an infrared hyperspectral imager and its flight test validation in laboratory
    Wang Jian-Yu
    Li Chun-Lai
    Lv Gang
    Yuan Li-Yin
    Wang Yue-Ming
    Jin Jian
    Chen Xiao-Wen
    Xie Feng
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2017, 36 (01) : 69 - 74
  • [50] System design of the CRISM (compact reconnaissance imaging spectrometer for Mars) hyperspectral imager
    Silverglate, PR
    Fort, DE
    Hopkins, J
    IMAGING SPECTROMETRY IX, 2003, 5159 : 283 - 290