Purpose: To evaluate the safety and efficacy of sealed implantation, a simple technique for implanting foldable intraocular lenses (IOLs). Methods: This was a retrospective study including consecutive patients who underwent phacoemulsification cataract using the sealed implantation technique. Sealed implantation is a technique in which a single-piece, foldable IOL is implanted without an intraocular ophthalmic viscosurgical device (OVD) or continuous infusion (hydroimplantation) of balanced saline solution (BSS). Forty consecutive patients who underwent clear corneal incision cataract surgery with IOL implantation using this technique were included. A 3-step 2.75-mm incision was performed approximately 0.5 mm anterior to the limbus with a 1.50 to 1.75 mm length as well as a 0.9 mm side port incision. Prior to the insertion of the IOL, the capsular bag and anterior chamber are filled with BSS. Hydroxypropyl methylcellulose 2% is applied external to the main corneal incision. The foldable IOL injector tip is introduced into the main incision in one quick jabbing motion and the IOL injected. The IOL is dialed with a standard irrigating Simcoe cannula. The main outcomes were intraoperative complications and postoperative hypotony. Results: Of 50 charts reviewed, sealed implantation was attempted in 40 (80%), with success in all cases. The injection of the IOL was performed without anterior chamber loss in 92% of the cases (n = 36) and no complications were recorded. There were no events of postoperative hypotony or wound leakage. Conclusions: Sealed implantation is a safe and efficient alternative to hydroimplantation without the need for OVDs in suitable cases.
引用
收藏
页码:555 / 558
页数:4
相关论文
共 50 条
  • [31] Implantation and capsular bag stability of single-piece, foldable EasAcryl 1 intraocular lenses
    Scorolli, L
    Scorolli, L
    Ricci, R
    Di Silvestre, L
    Morara, M
    Della Valle, V
    Meduri, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 521 - 526
  • [32] Variations in the clear-cornea incision size after foldable intraocular lenses implantation.
    MorenoMontanes, J
    GarciaLayana, A
    Da, DA
    Munuera, JM
    VISION RESEARCH, 1996, 36 : 60 - 60
  • [33] Pseudophakic accommodation with 2 models of foldable intraocular lenses
    Vámosi, P
    Nemeth, G
    Berta, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 221 - 226
  • [34] Adherence of Staphylococcus epidermidis to new foldable intraocular lenses
    Wood, CF
    John, T
    Lai, CI
    Carey, RB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 892 - 892
  • [35] Anterior capsule contraction with foldable silicone intraocular lenses
    Dahlhauser, KE
    Wroblewski, KT
    Mader, TH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (09): : 1216 - 1219
  • [36] In vivo comparison of silicone and acrylic foldable intraocular lenses
    Smith, JH
    Hwang, DG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2540 - 2540
  • [37] Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses
    Iseli, Hans Peter
    Jankov, Mirko
    Bueeler, Michael
    Wimmersberger, Yves
    Seiler, Theo
    Mrochen, Michael
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05): : 762 - 771
  • [38] Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia
    Islam M.Rizk
    Abd-Almonem A.Al-hessy
    Sherief E.El-Khouly
    Ashraf M.Sewelam
    International Journal of Ophthalmology, 2019, (02) : 284 - 290
  • [39] Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia
    Rizk, Islam M.
    Al-hessy, Abd-Almonem A.
    El-Khouly, Sheriefe
    Sewelam, Ashraf M.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (02) : 284 - 290
  • [40] Damage of foldable intraocular lenses by incorrect folder forceps
    Baldeschi, L
    Rizzo, S
    Nardi, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (02) : 245 - 247