Clinical and radiologic outcomes following total shoulder arthroplasty using Arthrex Eclipse stemless humeral component with minimum 2 years' follow-up

被引:23
|
作者
Gallacher, Sian [1 ]
Williams, Huw L. M. [1 ]
King, Andrew [1 ]
Kitson, Jeff [1 ]
Smith, Chris D. [1 ]
Thomas, William J. [1 ]
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Barrack Rd, Exeter EX2 5DW, Devon, England
关键词
Shoulder; arthroplasty; stemless prosthesis; shoulder replacement; outcomes; OSS; radiologic; ROM; PROSTHETIC DESIGN; HEAD SIZE; REPLACEMENT;
D O I
10.1016/j.jse.2018.05.039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Stemless humeral components benefit from less morbidity, better reproduction of the humeral anatomy, ease of revision. and fewer stein-related complications. Encouraging results are available up to 9 years after surgery from the designer's series. This is an independent study of 100 consecutive Eclipse stemless prostheses for osteoarthritis with a minimum 2-year follow-up (range, 2-6 years). Methods: We included only total shoulder arthroplasties performed for osteoarthritis. The primary outcome was the Oxford Shoulder Score (OSS) after 2 years. Secondary outcome measures were change in shoulder range of movement and radiographic analysis of prosthesis size and position. Results: The mean OSS at 2 years was 38 of 48. with a mean improvement of +19 points (range, +17 to +22 points; P < .001). There was no significant deterioration in OSS after 3 or 4 years' follow-up. Statistically significant improvement was seen in arm elevation and external rotation (P < .001). There were 5 reoperations-I for impingement of the biceps stump and 4 revisions to reverse arthroplasty for cuff failure. Of the prostheses, 92% were sized within 2 mm of the anatomic head size, and in 76% of prostheses, the center of rotation was within 3 mm of the native anatomy. An incomplete radiolucent line was present in zone B (around the cage screw) in a single patient at 2 years following surgery. There were no cases of loosening or infection. Conclusion: The functional and radiographic outcomes of Eclipse total shoulder replacement are excellent. We were able to accurately reproduce the native anatomy in the majority of cases. with no implant loosening. at 2 to 6 years' follow-up. (C) 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:2191 / 2197
页数:7
相关论文
共 50 条
  • [21] Clinical and radiologic outcomes of the second-generation Trabecular Metal™ glenoid for total shoulder replacements after 2–6 years follow-up
    Juan Paulo Panti
    Simon Tan
    Warren Kuo
    Sebastian Fung
    Kim Walker
    Jed Duff
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1637 - 1645
  • [22] Shoulder hemi arthroplasty radiological and clinical outcomes at more than two years follow-up
    Ohl, X.
    Nerot, C.
    Saddiki, R.
    Dehoux, E.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 208 - 215
  • [23] Minimum two-year follow-up of a reverse total shoulder arthroplasty using a wedged baseplate
    Parker, Simon J. M.
    Bell, Simon N.
    Wiemer, Feoline
    Coghlan, Jennifer A.
    Clitherow, Harry D.
    Rayment, Helen M.
    SHOULDER & ELBOW, 2024,
  • [24] Reverse shoulder arthroplasty for proximal humerus fracture using a dedicated stem: radiological outcomes at a minimum 2 years of follow-up—case series
    Raffaele Garofalo
    Brody Flanagin
    Alessandro Castagna
    Eddie Y Lo
    Sumant G Krishnan
    Journal of Orthopaedic Surgery and Research, 10
  • [25] Outcomes and complications of primary reverse shoulder arthroplasty with minimum of 2 years' follow-up: a systematic review and meta- analysis
    Galvin, Joseph W.
    Kim, Ryan
    Ment, Alexander
    Durso, Joseph
    Joslin, Patrick M. N.
    Lemos, Jacie L.
    Novikov, David
    Curry, Emily J.
    Alley, Maxwell C.
    Parada, Stephen A.
    Eichinger, Josef K.
    Li, Xinning
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (11) : E534 - E544
  • [26] Clinical and radiologic outcomes of the second-generation Trabecular Metal™ glenoid for total shoulder replacements after 2-6 years follow-up
    Panti, Juan Paulo
    Tan, Simon
    Kuo, Warren
    Fung, Sebastian
    Walker, Kim
    Duff, Jed
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1637 - 1645
  • [27] Grammont humeral design versus onlay curved-stem reverse shoulder arthroplasty: comparison of clinical and radiographic outcomes with minimum 2-year follow-up
    Merolla, Giovanni
    Walch, Gilles
    Ascione, Francesco
    Paladini, Paolo
    Fabbri, Elisabetta
    Padolino, Antonio
    Porcellini, Giuseppe
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (04) : 701 - 710
  • [28] Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2-to 7-year follow-up study
    Levy, Ofer
    Narvani, Ali
    Hous, Nir
    Abraham, Ruben
    Relwani, Jai
    Pradhan, Riten
    Bruguera, Juan
    Sforza, Giuseppe
    Atoun, Ehud
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (08) : 1362 - 1370
  • [29] Total shoulder arthroplasty - Arthroplasty for glenohumeral arthropathies: Results and complications after a minimum follow-up of 8 years according to the type of arthroplasty and etiology
    Favard, L.
    Katz, D.
    Colmar, M.
    Benkalfate, T.
    Thomazeau, H.
    Emily, S.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (04) : S41 - S47
  • [30] Results of total shoulder arthroplasty with a monoblock porous tantalum glenoid component: a prospective minimum 2-year follow-up study
    Budge, Matthew D.
    Nolan, Elizabeth M.
    Heisey, Meredith H.
    Baker, Kevin
    Wiater, J. Michael
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (04) : 535 - 541