Clinical and radiologic outcomes following total shoulder arthroplasty using Arthrex Eclipse stemless humeral component with minimum 2 years' follow-up

被引:23
|
作者
Gallacher, Sian [1 ]
Williams, Huw L. M. [1 ]
King, Andrew [1 ]
Kitson, Jeff [1 ]
Smith, Chris D. [1 ]
Thomas, William J. [1 ]
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Barrack Rd, Exeter EX2 5DW, Devon, England
关键词
Shoulder; arthroplasty; stemless prosthesis; shoulder replacement; outcomes; OSS; radiologic; ROM; PROSTHETIC DESIGN; HEAD SIZE; REPLACEMENT;
D O I
10.1016/j.jse.2018.05.039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Stemless humeral components benefit from less morbidity, better reproduction of the humeral anatomy, ease of revision. and fewer stein-related complications. Encouraging results are available up to 9 years after surgery from the designer's series. This is an independent study of 100 consecutive Eclipse stemless prostheses for osteoarthritis with a minimum 2-year follow-up (range, 2-6 years). Methods: We included only total shoulder arthroplasties performed for osteoarthritis. The primary outcome was the Oxford Shoulder Score (OSS) after 2 years. Secondary outcome measures were change in shoulder range of movement and radiographic analysis of prosthesis size and position. Results: The mean OSS at 2 years was 38 of 48. with a mean improvement of +19 points (range, +17 to +22 points; P < .001). There was no significant deterioration in OSS after 3 or 4 years' follow-up. Statistically significant improvement was seen in arm elevation and external rotation (P < .001). There were 5 reoperations-I for impingement of the biceps stump and 4 revisions to reverse arthroplasty for cuff failure. Of the prostheses, 92% were sized within 2 mm of the anatomic head size, and in 76% of prostheses, the center of rotation was within 3 mm of the native anatomy. An incomplete radiolucent line was present in zone B (around the cage screw) in a single patient at 2 years following surgery. There were no cases of loosening or infection. Conclusion: The functional and radiographic outcomes of Eclipse total shoulder replacement are excellent. We were able to accurately reproduce the native anatomy in the majority of cases. with no implant loosening. at 2 to 6 years' follow-up. (C) 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:2191 / 2197
页数:7
相关论文
共 50 条
  • [1] Stemless reverse shoulder arthroplasty: clinical and radiologic outcomes with minimum 2 years' follow-up
    Nabergoj, Marko
    Ladermann, Alexandre
    Authom, Thierry
    Beaudouin, Emmanuel
    Azar, Michel
    Wahab, Hassan
    Leger, Olivier
    Haight, Harrison
    Harris, Howard
    Collin, Philippe
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (09) : e464 - e474
  • [2] Stemless reverse shoulder arthroplasty clinical and radiological outcomes with minimum two years follow-up
    Martinho, Tiago
    Collin, Philippe
    Ladermann, Alexandre
    SWISS MEDICAL WEEKLY, 2022, 152 : 5S - 5S
  • [3] The radiographic and clinical outcomes of stemless reverse total shoulder arthroplasty: a minimum 2-year follow-up study
    Choi, Chang-Hyuk
    Choi, Ji Hoon
    Che, Sug Hun
    Kim, Jun-Young
    CLINICS IN SHOULDER AND ELBOW, 2024, 27 (04): : 428 - 436
  • [4] Early fixation of the humeral component in stemless total shoulder arthroplasty A RADIOSTEREOMETRIC AND CLINICAL STUDY WITH 24-MONTH FOLLOW-UP
    ten Brinke, B.
    Hesseling, B.
    Eygendaal, D.
    Hoelen, M. A.
    Mathijssen, N. M. C.
    BONE & JOINT JOURNAL, 2022, 104B (01): : 76 - 82
  • [5] Clinical results and computed tomography analysis of intuitive shoulder arthroplasty (ISA) stemless at a minimum follow-up of 2 years
    Gosselin, Cerise
    Lefebvre, Yves
    Joudet, Thierry
    Godeneche, Arnaud
    Barth, Johannes
    Garret, Jerome
    Audebert, Stephane
    Charousset, Christophe
    Institute, Shoulder Friends
    Bonnevialle, Nicolas
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (02) : e93 - e102
  • [6] Patient satisfaction and clinical outcomes of reverse shoulder arthroplasty: a minimum of 10 years' follow-up
    Sheth, Mihir M.
    Heldt, Brett L.
    Spell, Jennifer H.
    Vidal, Emily A.
    Laughlin, Mitzi S.
    Morris, Brent J.
    Elkousy, Hussein A.
    Edwards, T. Bradley
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (04) : 875 - 883
  • [7] Clinical and radiologic results after anatomic stemless shoulder prosthesis: a minimum 4-year follow-up
    Ambros, Leander
    Schoch, Christian
    Merz, Cornelia
    Huth, Jochen
    Mauch, Frieder
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (09) : 2082 - 2089
  • [8] Clinical Outcomes Following Revision Total Knee Arthroplasty: Minimum 2-Year Follow-up
    Quinn, Jonathan
    Jones, Peter
    Randle, Ray
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 69 - 75
  • [9] Clinical and radiographic outcomes following anatomic total shoulder arthroplasty utilizing an inset glenoid component at 2-year minimum follow-up: a dual center study
    Johnston, Peter S.
    Strony, John T.
    Churchill, Jessica L.
    Kankaria, Roma
    Sears, Benjamin W.
    Garrigues, Grant E.
    Gillespie, Robert J.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (06) : 1222 - 1230