A microfluidic passive pumping Coulter counter

被引:10
|
作者
McPherson, Amy L. [1 ,2 ]
Walker, Glenn M. [1 ,2 ]
机构
[1] N Carolina State Univ, Joint Dept Biomed Engn, Raleigh, NC 27695 USA
[2] Univ N Carolina Chapel Hill, Raleigh, NC USA
关键词
Microfluidics; Resistive pulse; Colloid; Enumeration; RESISTIVE-PULSE SENSOR; HIGH-THROUGHPUT; FLOW CYTOMETER; CHIP;
D O I
10.1007/s10404-010-0609-0
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A microfluidic device using on-chip passive pumping was characterized for use as a particle counter. Flow occurred due to a Young-Laplace pressure gradient between two 1.2-mm diameter inlets and a 4-mm diameter reservoir when 0.5-mu l fluid droplets were applied to the inlets using a micropipette. Polystyrene particles (10-mu m diameter) were enumerated using the resistive pulse technique. Particle counts using passive pumping were within 13% of counts from a device using syringe pumping. All pumping methods produced particle counts that were within 16% of those obtained with a hemocytometer. The effect of intermediate wash steps on particle counts within the passive pumping device was determined. Zero, one, or two wash droplets were loaded after the first of two sample droplets. No statistical difference was detected in the mean particle counts among the loading patterns (p > 0.05). Hydrodynamic focusing using passive pumping was also demonstrated.
引用
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [41] A Submicron Coulter Counter for Enumeration of Viruses and Nanoparticles
    Damhorst, Gregory
    Venkatesan, B. Murali
    Banerjee, Shouvik
    Solovyeva, Vita
    Bashir, Rashid
    BIOPHYSICAL JOURNAL, 2012, 102 (03) : 584A - 584A
  • [42] PLATELET COUNTING USING COULTER ELECTRONIC COUNTER
    EGGLETON, MJ
    SHARP, AA
    JOURNAL OF CLINICAL PATHOLOGY, 1963, 16 (02) : 164 - &
  • [43] Coulter counter registers talc particles as leukocytes
    Lee, YCG
    Lane, KB
    Light, RW
    CHEST, 2001, 119 (02) : 669 - 670
  • [44] PERFORMANCES OF THE COULTER S+II COUNTER
    MERLEBERAL, H
    BINET, JL
    NOUVELLE REVUE FRANCAISE D HEMATOLOGIE, 1984, 26 (01): : 45 - 52
  • [45] On-chip coulter counter for airdust monitor
    Miyamura, K
    Yoshida, Y
    Kitamori, T
    MICRO TOTAL ANALYSIS SYSTEMS 2004, VOL 1, 2005, (296): : 267 - 269
  • [46] MICROCALIBRATION OF THE COULTER-COUNTER MODEL S
    SIEGLE, MD
    AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1980, 46 (05): : 343 - 343
  • [47] Differentiating neutrophils using the optical coulter counter
    Schonbrun, Ethan
    Di Caprio, Giuseppe
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (11)
  • [48] USE OF COULTER COUNTER FOR DIFFERENTIAL HEMOLYSIS TECHNIC
    NIECE, RL
    FEDERATION PROCEEDINGS, 1964, 23 (2P1) : 141 - &
  • [49] COULTER COUNTER AS A TOOL FOR ESTIMATING NEMATODE NUMBERS
    NASH, RF
    FOX, RC
    JOURNAL OF INVERTEBRATE PATHOLOGY, 1969, 13 (01) : 153 - &
  • [50] Numerical simulation of deformable particles in a Coulter counter
    Taraconat, Pierre
    Gineys, Jean-Philippe
    Isebe, Damien
    Nicoud, Franck
    Mendez, Simon
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (11)