Cardiac resynchronization therapy reduces T-wave alternans in patients with heart failure

被引:5
|
作者
Hua, Wei [1 ,2 ,3 ,4 ]
Chen, Keping [1 ,2 ,3 ,4 ]
Zhou, Xiaohong [5 ]
Dai, Yan [1 ,2 ,3 ,4 ]
Chen, Ruohan [1 ,2 ,3 ,4 ]
Wang, Jing [1 ,2 ,3 ,4 ]
Ding, Ligang [1 ,2 ,3 ,4 ]
Liu, Zhiming [1 ,2 ,3 ,4 ]
Feng, Tianjie [1 ,2 ,3 ,4 ]
Yu, Jun [1 ,2 ,3 ,4 ]
Cheng, Jianwei [5 ]
Liu, Cherry [5 ]
Zhang, Shu [1 ,2 ,3 ,4 ]
机构
[1] Beijing Fuwai Hosp, Arrhythm Ctr, Beijing 100037, Peoples R China
[2] Beijing Fuwai Hosp, Clin EP Lab, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Natl Ctr Cardiovasc Dis, Beijing 100037, Peoples R China
[4] Peking Union Med Coll, Beijing 100037, Peoples R China
[5] Medtron Shanghai Management Co Ltd, CRDM, Shanghai 201203, Peoples R China
来源
EUROPACE | 2015年 / 17卷 / 02期
关键词
T-wave alternans; Ventricular tachyarrhythmia; Chronic heart failure; Implantable cardioverter-defibrillator; Cardiac resynchronization therapy; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; SPONTANEOUS VENTRICULAR-TACHYCARDIA; ELECTRICAL ALTERNANS; MECHANICAL ALTERNANS; SUDDEN-DEATH; PREDICTOR; TACHYARRHYTHMIAS; UTILITY; RISK;
D O I
10.1093/europace/euu258
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims T-wave alternans (TWA) represents myocardial instability. The present study was to determine the impact of cardiac resynchronization therapy (CRT) on TWA and left ventricular ejection fraction (LVEF) in heart failure patients. Methods and results T-wave alternans was analysed using a spectral method in 27 CRT-ICD patients. Ambulatory device electrograms were collected and LVEF and New York Heart Association (NYHA) classification were assessed at baseline prior to CRT and 3 months following CRT. Patients were followed for 6 months to monitor cardiac events. Spectral TWA of device electrograms was measured during AAI and CRT pacing tests. Each pacing mode had the up-titration pacing rate from 90 to 105 b.p.m. with 90 s for each pacing rate. At baseline, 20 (76.9%) patients had TWA during AAI pacing tests and 13 (50%) during CRT pacing tests (P = 0.044 between two pacing modes). Following 3-month CRT, TWA was identified in 11 patients (45.8%) during AAI pacing tests (a 31.1% reduction from the baseline value, P = 0.023) and 7 patients (28%) during CRT pacing tests (a 22% reduction, P = 0.108). Six of seven patients who had cardiac events had TWA (three patients had arrhythmic events, two died of heart failure, one received heart transplant). Overall, LVEF improved from 27.3 +/- 5.8 to 35.9 +/- 10.5% (P < 0.001) and NYHA classification improved from 2.8 +/- 0.6 to 1.6 +/- 0.6 after 3-month CRT (P < 0.001). Conclusion In heart failure patients who receive a CRT-ICD, CRT reduces TWA that is associated to cardiac events, suggesting that CRT promotes clinically significant reverse electrical and mechanical remodelling.
引用
收藏
页码:281 / 288
页数:8
相关论文
共 50 条
  • [41] T-wave area as biomarker of clinical response to cardiac resynchronization therapy
    Engels, E. B.
    Vegh, E. M.
    Van Deursen, C. J. M.
    Merkely, B.
    Vernooy, K.
    Singh, J. P.
    Prinzen, F. W.
    EUROPEAN HEART JOURNAL, 2015, 36 : 50 - 51
  • [42] Average T-wave alternans activity in ambulatory ECG records predicts sudden cardiac death in patients with chronic heart failure
    Monasterio, Violeta
    Laguna, Pablo
    Cygankiewicz, Iwona
    Vazquez, Rafael
    Bayes-Genis, Antoni
    Bayes de Luna, Antoni
    Pablo Martinez, Juan
    HEART RHYTHM, 2012, 9 (03) : 383 - 389
  • [43] REPRODUCIBILITY OF MICROVOLT T-WAVE ALTERNANS IN PATIENTS WITH ISCHEMIC HEART DISEASE
    Madias, J. E.
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2013, 15 (03): : 197 - 197
  • [44] Assessing risk for rehospitalization and cardiac death in patients with heart failure: Can the dynamic duo of heart rate turbulence and T-wave alternans help?
    Verrier, Richard L.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) : 1265 - 1267
  • [45] Imaging the Propagation of the Electromechanical Wave in Heart Failure Patients with Cardiac Resynchronization Therapy
    Bunting, Ethan
    Lambrakos, Litsa
    Kemper, Paul
    Whang, William
    Garan, Hasan
    Konofagou, Elisa
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (01): : 35 - 45
  • [46] Is T-wave alternans T-wave amplitude dependent?
    Burattini, Laura
    Zareba, Wojciech
    Burattini, Roberto
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2012, 7 (04) : 358 - 364
  • [47] CARDIAC RESYNCHRONIZATION THERAPY DECREASES P WAVE DISPERSION IN PATIENTS WITH HEART FAILURE
    Okutucu, S.
    Aytemir, K.
    Aksoy, H.
    Evranos, B.
    Fatihoglu, S. G.
    Sabanov, C.
    Sahiner, L.
    Kaya, E. B.
    Tokgozoglu, L.
    Kabakci, G.
    Ozkutlu, H.
    Oto, A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S94 - S95
  • [48] Crescendo T-Wave Alternans Prior to VT in Hospitalized Decompensated Heart Failure Patients In the PRECEDENT Trial
    Nearing, Bruce D.
    Wellenius, Gregory A.
    Mittleman, Murray A.
    Burger, Andrew J.
    Verrier, Richard L.
    CIRCULATION, 2008, 118 (18) : S833 - S833
  • [49] Influence of exercise training on T-wave alternans assessed during exercise test in heart failure patients
    Piotrowicz, Ewa
    Pencina, Michael
    Piotrowski, Walerian
    Banach, Maciej
    Piotrowicz, Ryszard
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (03) : 747 - 749
  • [50] Is microvolt T-wave alternans testing suitable for patients recently hospitalized due to decompensated heart failure?
    Danilowicz-Szymanowicz, Ludmila
    Molon, Giulio
    Raczak, Grzegorz
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 (01) : 112 - 112