Multi-leaf collimator quality assurance using pulse width modulation analysis

被引:0
|
作者
Shoales, J. [1 ]
Boyer, A. [1 ]
机构
[1] Scott & White Mem Hosp & Clin, Temple, TX USA
关键词
D O I
10.1118/1.2760976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a quality assurance (QA) methodology for prospective mechanical maintenance of multi‐leaf collimator (MLC) leaf positioning motors. Method and Materials: Pulse width modulation (PWM) analysis was used to assess the current performance status of the MLC leaf positioning motors for three medical linear accelerators in our clinic. PWM is a software diagnostic tool available as a built‐in component of the linear accelerator MLC controller computer interface (Varian Medical Systems, Inc. Palo Alto, CA). PWM probes the operational status of each MLC leaf motor by sending direct current (DC) pulses directly to the motor windings until each motor drives its individual leaf 2.0[mm] beyond four initial set positions. The DC pulse widths are incrementally increased by 2[ms] from an initial duration of 2[ms] to the length required for 2.0[mm] of MLC leaf displacement beyond the four set positions. The PWM values are stored for each position. Statistical process control (SPC) principles were applied to the data to establish process behavior characteristics. SPC limits were then applied to the PWM data and individual leaf performance statuses were analyzed. Our accelerator engineer serviced the MLC motors performing outside of the PWM SPC limits. The PWM analyses were repeated and compared with the previous results. Results: The established SPC limits for PWM average and range were 10[ms] and 3[ms], respectively. Two MLC motors (corresponding to MLC leaves 25 and 26) on carriage bank B were performing well beyond the calculated SPC limits. The corresponding motors were investigated and found to have broken motor drive hardware. The motors in question performed within SPC limits after reanalysis. Conclusion: PWM analysis for MLC mechanical QA required less than 5 minutes for data acquisition and was highly effective in diagnosing an MLC mechanical malfunction as part of a routine monthly QA procedure. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2474 / 2474
页数:1
相关论文
共 50 条
  • [21] Multi-leaf-collimator quality assurance using the electronic portal imaging device
    Ali, I
    Benedict, S
    Li, W
    Lerma, F
    Dogan, N
    Siebers, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2168 - 2168
  • [22] Development of the multi-leaf collimator for neutron capture therapy
    Kumada, H
    Kishi, T
    Hori, N
    Yamamoto, K
    Torii, Y
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 115 - 119
  • [23] Patient-Specific Quality Assurance Multi-Leaf Collimator Error Detection: Comparison of EPID and Array-Based Methods
    Roles, S.
    Winiecki, J.
    Rapchak, A.
    Owen, G.
    Mart, C.
    McDonald, D.
    Godwin, W.
    Maynard, M.
    Peng, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E895 - E896
  • [24] Clinical significance of multi-leaf collimator calibration errors
    Norvill, Craig
    Jenetsky, Guy
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 253 - 258
  • [25] Treatment set-up verification: quality assurance technique for LINAC-based stereotactic radiosurgery/radiotherapy using micro multi-leaf collimator
    Lazaridis, EA
    Xydis, K
    Theodorou, K
    Kappas, C
    Eble, MJ
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 73 - 73
  • [26] Treatment set-up verification: quality assurance technique for linac-based stereotactic radiosurgery/radiotherapy using micro multi-leaf collimator
    Lazaridis, E
    Xydis, K
    Theodorou, K
    Kappas, C
    Eble, M
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S436 - S436
  • [27] Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization
    Siebers, JV
    Lauterbach, M
    Keall, PJ
    Mohan, R
    MEDICAL PHYSICS, 2002, 29 (06) : 952 - 959
  • [28] Commissioning of multi-leaf collimator for fast neutron therapy
    Yudelev, M.
    Mogili, N.
    Hwang, T.
    Farr, J.
    Maughan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 2080 - 2080
  • [29] MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR
    KARLSSON, M
    ZACKRISSON, B
    RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) : 317 - 326
  • [30] Clinical significance of multi-leaf collimator calibration errors
    Craig Norvill
    Guy Jenetsky
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 253 - 258