Experimental and Numerical Analysis of the Transient Behavior of the Oil Decongealing Process in an Aero Fuel-Cooled Oil Cooler Under Low-Temperature Conditions

被引:6
|
作者
Kholi, Foster Kwame [1 ]
Park, Jaehyun [1 ]
Lee, Kyeongho [1 ]
Ha, Man Yeong [1 ]
Klingsporn, Michael [2 ]
Chetwynd-Chatwin, Jason [3 ]
Yoon, Sang Youl [4 ,5 ]
Min, June Kee [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63beon Gil, Busan 46241, South Korea
[2] Rolls Royce Deutschland Ltd & Co KG, Eschenweg 11, D-15827 Blankenfelde Mahlow, Germany
[3] Rolls Royce Plc, Whittle House,WH-42 POB 3, Bristol BS34 7QE, Avon, England
[4] Pusan Natl Univ, Rolls Royce, 2 Busandaehak Ro 63beon Gil, Busan 46241, South Korea
[5] Pusan Natl Univ, Pusan Natl Univ Technol Ctr, 2 Busandaehak Ro 63beon Gil, Busan 46241, South Korea
关键词
fuel cooled oil cooler; decongealing; compact heat exchangers; gas turbine engine; oil bypass valve; aerothermal management; low-temperature environment; HEAT-EXCHANGER; ENGINE OIL; FLOW;
D O I
10.1115/1.4051102
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The fuel-cooled oil cooler (FCOC) in the lubrication circuit plays a critical role in the aero gas-turbine engine's aerothermal management. However, the low temperature of the operating environment can congeal the oil and reduce the FCOC efficiency. The oil bypass valve (OBV) installed on the FCOC prevents pressure loss. Its failure may cause overheating, requiring preemptive performance prediction. Experimental and numerical analyses were used to evaluate the cooler's decongealing performance under typical boundary conditions of pressure and temperature, OBV configurations, and rerouting of feed oil and fuel flow paths. The temporal variation of oil and fuel mass flow rates, temperature, and pressure of the feed oil and fuel provided an insight into the decongealing process and duration. The experimental data were used to develop a one-dimensional (1D) flow and thermal network analysis model based on the effectiveness (epsilon)-number of thermal units (NTU) method to predict the transient oil decongealing performance of the FCOC. The customized commercial code predicted the decongealing phenomena using empirical correlations with property correction schemes, showing good agreement with the experiment. The findings revealed various ways to enhance the decongealing performance of the FCOC. The study results showed that the operating boundary conditions, OBV location and status, and flow arrangements affect decongealing behavior and time. The present numerical model provides results quickly and can effectively predict experimentally costly and complicated cases. The attempted estimates of steady heat rejection and detailed methodology could guide future studies and practical applications.
引用
收藏
页数:17
相关论文
共 40 条
  • [31] Analysis of Main Factors Affecting the Temperature-Maintaining Process of Crude Oil Tank Storage Under Dynamic Thermal Conditions
    Sun, Wei
    Liu, Yuduo
    Cheng, Qinglin
    Zhao, Lixin
    Wang, Zhihua
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 2024, 40 (01): : 205 - 220
  • [32] EXPERIMENTAL STUDY AND ANALYSIS OF ULTRA-LOW TEMPERATURE FUEL SPRAY WITH A HEAVY-DUTY INJECTOR UNDER VAPORIZING CONDITIONS
    Zhao, Zhihao
    Zhang, Anqi
    Schmidt, Henry
    Atkinson, William
    Naber, Jeffrey
    PROCEEDINGS OF ASME 2023 ICE FORWARD CONFERENCE, ICEF2023, 2023,
  • [33] Experimental and numerical study on non-monotonic effect of higher alcohols on ignition delay of diesel/alcohol blends under low-temperature conditions
    Li, Yikai
    Sun, Chenghan
    Yang, Ziming
    Fei, Chunguang
    Lou, Yue
    Wang, Dongfang
    Shi, Zhongjie
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 199
  • [34] Experimental and numerical studies of non-equilibrium solvent exsolution behavior and foamy oil stability under quiescent and convective conditions in a visualized porous media
    Wang, Hongyang
    Zeng, Fanhua
    Torabi, Farshid
    Xiao, Huiwen
    FUEL, 2021, 291
  • [35] Experimental study on the stable and dynamic characteristics during silicone oil spreading process on saline water sublayer with different salinities under various temperature conditions
    Li, Cong
    Zheng, Linlu
    Wang, Jiali
    Jin, Yanke
    Huang, Yuanxiu
    Yang, Rui
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 683
  • [36] LOW-TEMPERATURE RUPTURE BEHAVIOR OF ZIRCALOY-CLAD PRESSURIZED WATER-REACTOR SPENT FUEL-RODS UNDER DRY STORAGE-CONDITIONS
    EINZIGER, RE
    KOHLI, R
    NUCLEAR TECHNOLOGY, 1984, 67 (01) : 107 - 123
  • [37] Identifiability Analysis of Degradation Model Parameters from Transient CO2 Release in Low-Temperature PEM Fuel Cell under Various AST Protocols
    Kravos, Andraz
    Kregar, Ambroz
    Mayer, Kurt
    Hacker, Viktor
    Katrasnik, Tomaz
    ENERGIES, 2021, 14 (14)
  • [38] A new method to predict high and low-temperature ignition delays under transient thermodynamic conditions and its experimental validation using a Rapid Compression-Expansion Machine
    Desantes, Jose M.
    Bermudez, Vicente
    Javier Lopez, J.
    Lopez-Pintor, Dario
    ENERGY CONVERSION AND MANAGEMENT, 2016, 123 : 512 - 522
  • [39] Experimental validation of an alternative method to predict high and low-temperature ignition delays under transient thermodynamic conditions for PRF mixtures using a Rapid Compression-Expansion Machine
    Desantes, Jose M.
    Bermudez, Vicente
    Javier Lopez, J.
    Lopez-Pintor, Dario
    ENERGY CONVERSION AND MANAGEMENT, 2016, 129 : 23 - 33
  • [40] Experimental and numerical investigation of the auto-ignition characteristics of cylinder oil droplets under low-speed two-stroke natural gas engines in-cylinder conditions
    Wang, Zixin
    Zhang, Dong
    Fang, Yuan
    Song, Meijia
    Gong, Zhen
    Feng, Liyan
    FUEL, 2022, 329