Fluorescence determination of N-acetylaspartic acid in the rat cerebrum homogenate using high-performance liquid chromatography with pre-column fluorescence derivatization

被引:9
|
作者
Fukushima, Takeshi [1 ]
Arai, Kotaro [1 ]
Tomiya, Masayuki [1 ]
Mitsuhashi, Shogo [1 ]
Sasaki, Tsukasa [1 ]
Santa, Tomofumi [2 ]
Imai, Kazuhiro [3 ]
Toyo'oka, Toshimasa [1 ]
机构
[1] Univ Shizuoka, Sch Pharmaceut Sci, Div Bioanalyt Chem, Suruga Ku, Shizuoka 4228526, Japan
[2] Univ Tokyo, Grad Sch Pharmaceut Sci, Dept Bioanalyt Chem, Tokyo 1130033, Japan
[3] Musashino Univ, Res Inst Pharmaceut Sci, Tokyo 2028585, Japan
关键词
N-Acetyl-L-aspartic acid; HPLC; DBD-ED; rat cerebrum homogenate; fluorescence detection;
D O I
10.1002/bmc.902
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
N-Acetyl-L-aspartic acid (NAA) is an endogenous compound, and its brain concentration is suggested to be altered in neurological disorders. In the present study, a fluorescence determination method for NAA was developed by employing reversed-phase high-performance liquid chromatography (HPLC) with pre-column fluorescence derivatization using 4-N,N-dimethylaminosulfonyl-7-N-(2-aminoethyl)amino-2,1,3-benzoxadiazole (DBD-ED). Using methylsuccinic acid as the internal standard, a linear calibration curve for NAA was constructed in the range 125-1000 mu m (n = 3). The detection limit on the column was approximately 5.0 fmol (signal-to-noise ratio 3). The proposed HPLC method was applied to determine NAA in the rat cerebrum homogenate. Cerebrum NAA was successfully determined using 10 mu L of the homogenate, and the validation data for the proposed HPLC method demonstrated satisfactory results. Intra- and inter-day precision and accuracy were within 1.1-7.0 and -8.1-6.3%, respectively. The concentration of NAA in the male rat cerebrum (13 weeks old) was 84 +/- 4.6 mu mol/mg protein (n 3). Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [21] In Vitro Permeability Study of Homotaurine Using a High-Performance Liquid Chromatography with Fluorescence Detection Pre-Column Derivatization Method
    Ntorkou, Marianna
    Tsanaktsidou, Eleni
    Chachlioutaki, Konstantina
    Fatouros, Dimitrios G.
    Markopoulou, Catherine K.
    MOLECULES, 2023, 28 (20):
  • [22] Determination of netilmicin in rat plasma by reversed-phase high performance liquid chromatography with fluorescence detection and pre-column derivatization
    Chang Xiaojuan
    Peng Jingdong
    Liu Shaopu
    Liu Limin
    Dai Yongkuang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (06) : 794 - 798
  • [23] Determination of seven biothiols in rice by high performance liquid chromatography-fluorescence detection with pre-column derivatization
    Zhou Rong
    Cao Zhaoyun
    Mou Renxiang
    Li Zhengxiang
    Chen Mingxue
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (01) : 35 - 39
  • [24] DETERMINATION OF THE BISPHOSPHONATE PAMIDRONATE DISODIUM IN URINE BY PRE-COLUMN DERIVATIZATION WITH FLUORESCAMINE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION
    FLESCH, G
    HAUFFE, SA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (02): : 446 - 451
  • [25] Analysis of phytochelatins in plant matrices by pre-column derivatization, high-performance liquid chromatography and fluorescence-detection
    S. Döring
    S. Korhammer
    M. Oetken
    B. Markert
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 316 - 318
  • [26] Analysis of phytochelatins in plant matrices by pre-column derivatization, high-performance liquid chromatography and fluorescence-detection
    Döring, S
    Korhammer, S
    Oetken, M
    Markert, B
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (03): : 316 - 318
  • [27] DETERMINATION OF VANILLYLMANDELIC ACID IN URINE BY PRE-COLUMN DANSYLATION USING MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    YAMADA, K
    KAYAMA, E
    AIZAWA, Y
    OKA, K
    HARA, S
    JOURNAL OF CHROMATOGRAPHY, 1981, 223 (01): : 176 - 178
  • [28] Simultaneous Determination of Amoxicillin and Ampicillin in Eggs by Reversed-Phase High-Performance Liquid Chromatography with Fluorescence Detection using Pre-Column Derivatization
    Xie, Kaizhou
    Jia, Longfei
    Xu, Dong
    Guo, Huisheng
    Xie, Xing
    Huang, Yuping
    Chen, Xuesen
    Bao, Wenbin
    Dai, Guojun
    Wang, Jinyu
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) : 620 - 624
  • [29] Determination of ethambutol in plasma by high-performance liquid chromatography after pre-column derivatization
    Chenevier, P
    Massias, L
    Gueylard, D
    Farinotti, R
    JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2): : 310 - 315
  • [30] HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY DETERMINATION OF ANILINES WITH FLUORESCENT DETECTION AND PRE-COLUMN DERIVATIZATION
    Al-Kindy, Salma M. Z.
    Al-Kalbani, Azza
    Al-Harasi, Ahmed F.
    Suliman, FakhrEldin O.
    Al-Lawati, Haider J.
    Al-Hamadi, Abdalla
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (01) : 48 - 59