Images registration & superimposition for dual resolution cone beam CT: a preliminary study

被引:0
|
作者
You, Zhicheng [1 ]
Shen, Youtao [1 ]
Zhong, Yuncheng [1 ]
Chen, Lingyun [1 ]
Han, Tao [1 ]
Ge, Shuaiping [1 ]
Yi, Ying [1 ]
Wang, Tianpeng [1 ]
Lai, Chao-Jen [1 ]
Liu, Xinming [1 ]
Shaw, Chris C. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
关键词
Dual-resolution cone beam CT; Volume of interest; VOI mask; FDK reconstruction;
D O I
10.1117/12.844450
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Registration and superimposition of images acquired from two different detectors is essential to dual-resolution cone beam CT. In this study we implemented and tested a method of integration, which is to register and superimpose the high resolution volume of interest (VOI) only images to the low resolution full field images. First, we acquired two images sets: One is low exposure low resolution full field images acquired with a low resolution detector; the other is high exposure high resolution volume of interest (VOI) images acquired with a high resolution detector and VOI mask. To locate the VOI positions in full field images, the third images set with VOI mask but without phantom was acquired with the low resolution detector. In the third images set, high contrast VOI boundaries were located and used to determine positions of the VOI in full field images. Then high resolution VOI images were superimposed with the full field images to generate integrated images set. Integrated images set was tested by subtraction from full field images set and then used to reconstruct images using regular FDK algorithm. In the reconstructed images, five Al wires (as small as 152 mu m) can be clearly seen in the VOI.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Dual resolution cone beam breast CT: A feasibility study
    Chen, Lingyun
    Shen, Youtao
    Lai, Chao-Jen
    Han, Tao
    Zhong, Yuncheng
    Ge, Shuaiping
    Liu, Xinming
    Wang, Tianpeng
    Yang, Wei T.
    Whitman, Gary J.
    Shaw, Chris C.
    MEDICAL PHYSICS, 2009, 36 (09) : 4007 - 4014
  • [2] VMAT Dose Calculations Using Cone Beam CT Images: A Preliminary Study
    Yu, S.
    Sehgal, V.
    Kuo, J.
    Daroui, P.
    Ramsinghani, N.
    Al-Ghazi, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 321 - 321
  • [3] Feasibility of dual-resolution cone beam breast CT: a simulation study
    Chen, Lingyun
    Shaw, Chris C.
    Lai, Chao-Jen
    Han, Tao
    Liu, Xinming
    Wang, Tianpeng
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [4] Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy
    Paquin, Dana
    Levy, Doron
    Xing, Lei
    MEDICAL PHYSICS, 2009, 36 (01) : 4 - 11
  • [5] A Segmentation-Based Deformable Registration Algorithm for Cone Beam CT and Helical CT Images
    Li, X.
    Li, T.
    Yang, Y.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [6] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Altman, A
    Koehler, T
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2973 - 2977
  • [7] High-resolution images of cone beam collimated CT scans
    Shechter, G
    Koehler, T
    Altman, A
    Proksa, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 247 - 255
  • [8] Superimposition of Cone-Beam Computed Tomography Images by Joint Embedding
    Pei, Yuru
    Ma, Gengyu
    Chen, Gui
    Zhang, Xiaoyun
    Xu, Tianmin
    Zha, Hongbin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (06) : 1218 - 1227
  • [9] Registration of volumetric KV or MV cone beam CT with fan beam CT
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1895 - 1895
  • [10] Spatial resolution properties in cone beam CT: A simulation study
    Chen, Lingyun
    Shaw, Chris C.
    Altunbas, Mustafa C.
    Lai, Chao-Jen
    Liu, Xinming
    MEDICAL PHYSICS, 2008, 35 (02) : 724 - 734