B-Scan in a Reverberation Chamber

被引:14
|
作者
Xu, Qian [1 ]
Huang, Yi [1 ]
Xing, Lei [2 ]
Tian, Zhihao [1 ]
Stanley, Manoj [1 ]
Yuan, Sheng [1 ]
机构
[1] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
[2] Nanjing Univ Aeronaut & Astronaut, Coll Elect & Informat Engn, Nanjing 211106, Jiangsu, Peoples R China
关键词
B-scan; reverberation chamber (RC); scattering cross section; stirrer efficiency; time-domain technique; MULTIFREQUENCY MEASUREMENTS;
D O I
10.1109/TAP.2016.2535121
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the B-scan technique is applied to a reverberation chamber (RC) for the first time to characterize the time-domain behavior of the chamber. Based on B-scan measurement results, three things are studied in this paper. 1) The statistical behavior of the fields in the time domain is investigated, and it is found that the received power of the impulse response follows chi-square distribution with one degree of freedom. 2) The stirrer efficiency is quantified based on the equivalent total scattering cross section (TSCS) of stirrers, and this definition is not sensitive to the antenna position and load in the RC. It is shown that the stirrer efficiency defined in this paper provides, for the first time, a quantitative way to evaluate the stirrer design and the chamber performance. 3) A time-gating technique is proposed which provides an alternative method to eliminate the early time response and obtain the chamber transfer function of the RC accurately. This could be potentially used to increase the stirrer efficiency without changing the stirrers physically. It is demonstrated that the B-scan technique is a very useful approach for the study and evaluation of an RC.
引用
收藏
页码:1740 / 1750
页数:11
相关论文
共 50 条
  • [21] ORBITAL ULTRASONIC TOMOGRAPHY (B-SCAN)
    COLEMAN, DJ
    [J]. TRANSACTIONS AMERICAN ACADEMY OF OPHTHALMOLOGY AND OTOLARYNGOLOGY, 1974, 78 (04): : O577 - O580
  • [22] B-SCAN ULTRASONOGRAPHY OF ORBITAL VARICES
    宋国祥
    肖利华
    [J]. 中华医学杂志(英文版), 1982, (11) : 855 - 860
  • [23] Sparse deconvolution of B-scan images
    Olofsson, Tomas
    Wennerstrom, Erik
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) : 1634 - 1641
  • [24] ULTRASOUND HOLOGRAPHIC B-SCAN IMAGING
    YLITALO, J
    ALASAARELA, E
    KOIVUKANGAS, J
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (03) : 376 - 383
  • [25] B-SCAN ULTRASONOGRAPHY OF ORBITAL MUCOCOELES
    COLEMAN, DJ
    FRANZEN, LA
    JACK, RL
    [J]. EYE EAR NOSE AND THROAT MONTHLY, 1972, 51 (06): : 207 - &
  • [26] CONTACT B-SCAN ULTRASOUND OF THE BREAST
    LALANI, Z
    JACKSON, FI
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 : 235 - 242
  • [27] VALUE OF GALLBLADDER B-SCAN ULTRASONOGRAPHY
    TABRISKY, J
    LINDSTROM, RR
    HERMAN, MW
    CASTAGNA, J
    SARTI, D
    [J]. GASTROENTEROLOGY, 1975, 68 (05) : 1246 - 1252
  • [28] REALISTIC SIMULATION OF B-SCAN IMAGES
    SEGGIE, DA
    BURGE, RE
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (01): : 107 - 108
  • [29] OCULAR DIAGNOSIS WITH B-SCAN ULTRASONOGRAPHY
    LINDE, CJ
    EPSTEIN, D
    JERNDAL, B
    ALGVERE, P
    [J]. ACTA OPHTHALMOLOGICA, 1977, 55 (05): : 879 - 879
  • [30] B-SCAN ULTRASONOGRAPHY OF THE EYE AND ORBIT
    ROCHELS, R
    REIS, G
    [J]. FORTSCHRITTE DER MEDIZIN, 1979, 97 (37) : 1598 - &