Turbo generator stator winding condition assessment

被引:0
|
作者
Arshad, M
Khaliq, A
Islam, SM
机构
关键词
stator winding; insulation response; diagnostics; asset management;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Stator winding is a main component of generator. Electrical, mechanical, thermal and environmental stresses remain major factors for insulation degradation and accelerated aging. A large number of generators failed due to stator winding problems, mainly insulation deterioration. Insulation degradation assessment plays vital role in the asset life management. Mostly the stator failure is catastrophic causing significant damage to the plant and the environment. Other than generation loss, stator failure involves heavy repair and / or replacement cost. Early fault detection would be an important tool to implement condition-based maintenance (CBM) for asset better management Condition based maintenance offers scheduled outages and reduces failure risks in old asset as wen as premature failure in the new one. The winding insulation trend can be best analyzed by using online partial discharge monitoring. In windings insulation system, the energy discharge mainly occurs on the surface, slot, end winding, inter-turn and between bars. Slot discharge is dangerous in Us kind and plays an important role in the accelerated insulation degradation. On the detection of partial discharge activity, accurate interpretation can establish insulation trending for stator insulation assessment. Hot spot can lead to catastrophic failure if not caught in time. Effective monitoring will reduce the life cycle cost with improved reliability and better asset management. This paper presents a detailed case study of generator stator winding failure leading to core damage.
引用
收藏
页码:1399 / 1403
页数:5
相关论文
共 50 条
  • [31] GENERATOR STATOR END WINDING RESONANCE: PROBLEMS AND SOLUTIONS
    Moore, Bill
    Maughan, Clyde
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE, 2013, VOL 1, 2014,
  • [32] Study on Double Winding Stator Induction Generator System
    Yu, Yao
    Li, LiHua
    [J]. 2011 INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND CONTROL (ICECC), 2011, : 2313 - 2315
  • [33] Assessment of insulation condition of generator stator bars based on velocity of ultrasonic waves
    Hao, YP
    Xie, HK
    Wang, GL
    Jia, ZD
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (03) : 539 - 547
  • [35] Discussion on way of connection to neutral point and turn-to-turn fault protection for stator winding of large turbo-generator
    Fu, Ziqing
    Chen, Wenxue
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2000, 24 (09): : 63 - 66
  • [36] Analysis of turbo-generator circulating current between stator winding parallel-connected branches under fault conditions
    Wan shuting
    Li Heming
    Li Yonggang
    Meng Fanchao
    [J]. PROCEEDINGS OF THE ASME POWER CONFERENCE 2005, PTS A AND B, 2005, : 411 - 415
  • [37] Determination of control winding current and stator frequency for dual stator-winding high-speed induction generator
    Wu, Xin-Zhen
    Wang, Xiang-Heng
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (18): : 23 - 29
  • [38] Vibration analysis of large turbo-generator stator system
    Qing, GH
    Qiu, JJ
    Hu, YD
    [J]. POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 2168 - 2172
  • [39] A novel stator winding capacitance dividing method for the generator with considerable winding distributed capacitance
    Tao, Yonghong
    Tian, Qing
    Lin, Xiangning
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1956 - 1961
  • [40] A Perspective on Online Partial Discharge Monitoring for Assessment of the Condition of Rotating Machine Stator Winding Insulation
    Stone, G. C.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (05) : 8 - 13