Capsule excision and Ologen™ implantation for revision after glaucoma drainage device surgery

被引:24
|
作者
Rosentreter, Andre [1 ]
Mellein, Anne C. [1 ]
Konen, Walter W. [1 ]
Dietlein, Thomas S. [1 ,2 ]
机构
[1] Univ Cologne, Dept Ophthalmol, D-50931 Cologne, Germany
[2] Univ Dusseldorf, D-40225 Dusseldorf, Germany
关键词
Glaucoma drainage device; Biodegradable implant; Ologen (TM) implant; Capsule excision; REFRACTORY GLAUCOMA; FILTERING BLEBS; ANIMAL-MODEL; COLLAGEN; TRABECULECTOMY; VALVE; FILM; EYES;
D O I
10.1007/s00417-010-1385-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
There is little information available about surgical management after failed glaucoma drainage device (GDD) surgery. We present the outcome of capsule excision after failed GDD surgery compared to capsule excision with additional use of a biodegradable implant (Ologen (TM), version 2) as a placeholder. In an observational comparative case series of 19 patients undergoing excision of the GDD capsule, ten prospectively observed consecutive patients were treated by excision of the capsule, topical mitomycin C application, and implantation of an 10 x 10 x 2 mm-sized Ologen (TM) implant (group A) while 9 retrospectively observed consecutive patients were treated by excision of the capsule and topical mitomycin C application alone (group B). Mean preoperative IOP was 29.4 mmHg for group A and 27.6 mmHg for group B, while mean postoperative IOP at the last follow-up (mean follow-up 11.2 (group A) and 8.6 (group B) months) was 17.3 mmHg for group A and 19.3 mmHg for group B (p > 0.05). Follow-up of the two groups demonstrated a significant difference in success rate (log-rank test, p = 0.04) in favor of group A. No further pressure-reducing surgery was necessary in any of the patients in group A, but it was needed in three of nine patients in group B. Although our study has the limitations of small sample size and observational study design, it shows that further investigation is warranted into the potential of Ologen (TM) in revision surgery after GDD implantation.
引用
收藏
页码:1319 / 1324
页数:6
相关论文
共 50 条
  • [31] Complications of Glaucoma Drainage Device Surgery: A Review
    Giovingo, Michael
    [J]. SEMINARS IN OPHTHALMOLOGY, 2014, 29 (5-6) : 397 - 402
  • [32] Glaucoma Drainage Device Surgery Outcomes in Children With Uveitic Glaucoma
    Gkaragkani, Evangelia
    Jayaram, Hari
    Papadopoulos, Maria
    Pavesio, Carlos
    Brookes, John
    Khaw, Peng T.
    El Sayed, Yasmine M.
    Clarke, Jonathan
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 251 : 5 - 11
  • [33] Glaucoma drainage device surgery outcomes for pediatric uveitic glaucoma
    Clarke, Jonathan C.
    Gkaragkani, Evangelia
    Papadopoulos, Maria
    Pavesio, Carlos
    Brookes, John
    Khaw, Peng Tee
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [34] Endophthalmitis With Corneal Infiltrate After EX-PRESS Glaucoma Drainage Device Implantation
    Cherof, Amy M.
    SooHoo, Jeffery R.
    Kahook, Malik Y.
    Seibold, Leonard K.
    [J]. JOURNAL OF GLAUCOMA, 2016, 25 (03) : E277 - E279
  • [35] Human amniotic membrane transplantation for tube exposure after glaucoma drainage device implantation
    Papadaki, Thekla G.
    Siganos, Charalambos S.
    Zacharopoulos, Ioannis P.
    Panteleontidis, Vasssilios
    Charissis, Spyridon K.
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (01) : 171 - 172
  • [36] Long-term Visual Field Outcomes after Glaucoma Drainage Device Implantation
    Yarur, Daniela
    De Gainza, Agustina
    Morales, Esteban
    Caprioli, Joseph
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [37] Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation
    Jung, Kyoung In
    Park, Chan Kee
    [J]. DRUG DESIGN DEVELOPMENT AND THERAPY, 2016, 10 : 1477 - 1488
  • [38] Need for Additional Glaucoma Surgery and Complications Following Glaucoma Drainage Device Surgery
    Kung, Felix F.
    Knier, Catherine G.
    Garmany, Armin
    Mejia, Camilo A.
    Sargent, Jason M.
    Dogahe, Sepideh Jamali
    Sabbagh, Nouran
    Hodge, David O.
    Khanna, Cheryl L.
    [J]. JOURNAL OF GLAUCOMA, 2021, 30 (06) : 508 - 514
  • [39] Intraluminal Suture Placement for Management of Hypotony After Glaucoma Drainage Device Surgery
    Tang, Minjia
    Anchala, Anupama R.
    Tanna, Angelo P.
    [J]. JOURNAL OF GLAUCOMA, 2024, 33 (08) : 607 - 611
  • [40] Ocular motility disturbances after glaucoma drainage device implantation for paediatric glaucoma: a cross-sectional study
    Leahy, Kate Elspeth
    MacNeill, Katelyn
    Locke, Jeff
    Sobey, Stephanie
    Kraft, Stephen P.
    Ali, Asim