PC-controlled laser diode system application

被引:0
|
作者
Chang, CJ [1 ]
Hsiao, PY
Yang, PH
Jane, ST
机构
[1] Natl Taiwan Univ, Dept Ind Educ, Taipei 106, Taiwan
[2] Aetex Biometr Corp, Taipei 110, Taiwan
[3] Natl Chung Cheng Univ, Dept Elect Engn, Chiayi, Taiwan
[4] Prov Yang Mei Senior High Sch, Elect Grp, Tao Yuang Hsein 326, Taiwan
关键词
color printing; image processing; laser diode; XY table;
D O I
10.1109/28.753634
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a system with personal-computer (PC)-controlled laser-diode beam to make film exposures for generating 256 gray-level images. The hardware equipment of this system includes an IBM PC, an 8255 interface card, and an XY table. Control software is developed to receive image data from commercially available software, such as PAINT SHOP, then convert them to signals for the laser diode and XY table. The gray level of each pixel (picture element) in an image file is represented by an 8-bit binary number. Two ways of control are demonstrated. One way uses this 8-bit number as a parameter for timing delay when the laser diode is on with a constant power output. The other way uses this 8-bit number to go through a D/A converter to control the laser diode for outputting beams with varying intensity. This way may gain higher operation speed, but requires extra hardware. There are two potential applications for this system. One is direct image exposure of yellow, magenta, cyan, and black for all image processing software data outputs, as long as their format is available. The other is for an educational training program to demonstrate the technologies of integrating computer, laser, and color printing.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 50 条
  • [21] PC-controlled radiochemistry system for preparation of no-carrier-added 64Cu
    Rebeles, R. Adam
    Van den Winkel, P.
    Hermanne, A.
    De Vis, L.
    Waegeneer, R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 286 (03) : 655 - 659
  • [22] Manipulation of living cells by using PC-controlled micro-pattern projection system
    Sumaru, Kimio
    Edahiro, Jun-ichi
    Oshima, Yuki
    Kanamori, Toshiyuki
    Shinbo, Toshio
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10): : 2356 - 2359
  • [23] A new PC-controlled device for emittance and brightness measurements
    Scheloske, S
    Dürr, W
    Maetz, M
    Pfahler, R
    Repnow, R
    Schiebler, H
    Traxel, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 161 : 302 - 307
  • [24] A PC-controlled microwave tomographic scanner for breast imaging
    Padhi, Shantanu
    Howard, John
    Fhager, A.
    Bengtsson, Sebastian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (01):
  • [25] Quality Management Issues for PC-Controlled Calibration Systems
    Carullo, Alessio
    Luoni, Alessia
    Neri, Alessandra
    La Paglia, Giuseppe
    Suriani, Giulia
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1563 - +
  • [26] A PC-CONTROLLED SMALL-POWER MOTOR TEST RIG
    SRB, K
    EGGER, J
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1989, 97 (07): : 305 - 308
  • [27] 16-bit PWM optoisolated DAC is PC-controlled
    Woodward, WS
    ELECTRONIC DESIGN, 2001, 49 (17) : 83 - 84
  • [28] PC-CONTROLLED INSTRUMENTS ARE ALIVE AND WELL IN UNITED-STATES
    BLAKESLEE, T
    EDN, 1989, 34 (21) : 34 - 34
  • [29] PC-Controlled, Real-Time Spectrum Analyzer Family
    不详
    MICROWAVE JOURNAL, 2015, 58 (07) : 109 - 109