A patch-clamp study on human sperm Cl- channel reassembled into giant liposome

被引:0
|
作者
Bai, JP [1 ]
Shi, YL [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Biol Sci, Inst Physiol, Key Lab Neurobiol, Shanghai 200031, Peoples R China
关键词
Cl-; channel; giant liposome; patch clamp; human sperm membrane; ion channel reassembly;
D O I
暂无
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
Aim: To record the single-channel currents and characterize the electrophysiological properties of the Cl- channels in human sperm membrane. Methods: The membrane proteins extracted from the human sperm were reassembled into liposome bilayer, and the liposomes were fused into giant liposomes with a diameter more than 10 mum by dehydrationrehydration procedure. The giant liposomes were used to study the Cl- channel activities by patch-clamp technique. Results: By patch clamping the giant liposome in an asymmetric NMDG (N-methyl-D-glucamine)-Cl (bath 100// pipette 200 mmol/L) solution system, three kinds of single-channel events with unit conductances of (74.1 +/- 8.3) pS,. (117.0 +/- 5.7) pS and (144.7 +/- 4.5.) pS, respectively, were detected. Their activities were voltage-dependent and all were blocked by SITS (4-acetamido-4'-isothiocyanato-stilbene-2', 2'-disulfonic acid) in a concentration-dependent manner. By constructing the open and close dwell time distribution histograms and then fitting them with exponential function, two time constants were obtained in both the open and the close states. The burst activity and conductance substate of the channels were observed. Conclusion: There exist three kinds of Cl- channels with different conductance in human sperm membrane at least.
引用
下载
收藏
页码:185 / 191
页数:7
相关论文
共 50 条
  • [41] PATCH-CLAMP ANALYSIS OF THE SLOW-CHANNEL MYASTHENIC SYNDROME (SCMS)
    HUTCHINSON, DO
    NAKANO, S
    SIEB, JP
    ENGEL, AG
    NEUROLOGY, 1993, 43 (04) : A180 - A181
  • [42] Patch-clamp technique to study mitochondrial membrane biophysics
    Kumari, Anshu
    Nguyen, Dung M. M.
    Garg, Vivek
    JOURNAL OF GENERAL PHYSIOLOGY, 2023, 155 (08):
  • [43] Patch-clamp measurements of capacitance to study exocytosis and endocytosis
    Homann, U
    Tester, M
    TRENDS IN PLANT SCIENCE, 1998, 3 (03) : 110 - 114
  • [44] A PATCH-CLAMP STUDY OF HISTAMINE-SECRETING CELLS
    LINDAU, M
    FERNANDEZ, JM
    JOURNAL OF GENERAL PHYSIOLOGY, 1986, 88 (03): : 349 - 368
  • [45] A CA-2+-DEPENDENT AND VOLTAGE-DEPENDENT CL--SENSITIVE ANION CHANNEL IN THE CHARA PLASMALEMMA - A PATCH-CLAMP STUDY
    OKIHARA, K
    OHKAWA, T
    TSUTSUI, I
    KASAI, M
    PLANT AND CELL PHYSIOLOGY, 1991, 32 (05) : 593 - 601
  • [46] One-channel Cell-attached Patch-clamp Recording
    Maki, Bruce A.
    Cummings, Kirstie A.
    Paganelli, Meaghan A.
    Murthy, Swetha E.
    Popescu, Gabriela K.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (88):
  • [47] AUTOMATIC PROCESSING OF SINGLE CHANNEL CURRENTS USING PATCH-CLAMP METHOD
    CHRISTE, G
    TADARY, B
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1987, 80 (05): : 733 - 733
  • [48] SINGLE-CHANNEL PATCH-CLAMP STUDY OF MITOCHONDRIA-RICH CELLS OF TOAD SKIN
    LARSEN, EH
    SORENSEN, JB
    WILLUMSEN, NJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1995, 489P : S18 - S19
  • [49] PORINS OF ESCHERICHIA-COLI RECONSTITUTED IN GIANT LIPOSOMES AND STUDIED BY PATCH-CLAMP
    GHAZI, A
    BERRIER, C
    COULOMBE, A
    HOUSSIN, C
    FASEB JOURNAL, 1992, 6 (01): : A513 - A513
  • [50] Patch-clamp fluorometry-based channel counting to determine HCN channel conductance
    Liu, Chang
    Xie, Changan
    Grant, Khade
    Su, Zhuocheng
    Gao, Weihua
    Liu, Qinglian
    Zhou, Lei
    JOURNAL OF GENERAL PHYSIOLOGY, 2016, 148 (01): : 65 - 76