Analysis of hydrofluoric acid penetration and decontamination of the eye by means of time-resolved optical coherence tomography

被引:28
|
作者
Spoeler, Felix [1 ]
Frentz, Markus [2 ,3 ]
Foerst, Michael [1 ]
Kurz, Heinrich [1 ]
Schrage, Norbert F. [2 ,3 ,4 ]
机构
[1] Rhein Westfal TH Aachen, Inst Semicond Elect, D-52074 Aachen, Germany
[2] Aachen Ctr Technol Transfer Ophthalmol, D-52070 Aachen, Germany
[3] Univ Aachen, Dept Ophthalmol, D-52057 Aachen, Germany
[4] Dept Ophthalmol Cologne Merheim, D-51109 Cologne, Germany
关键词
eye irritation; eye burn; Hydrofluoric acid burn; optical coherence tomography; hexafluorine;
D O I
10.1016/j.burns.2007.05.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
So far the study of chemical burns has lacked techniques to define penetration kinetics and the effects of decontamination within biological structures. in this study, we aim to demonstrate that high-resolution optical coherence tomography (HR-OCT) can close this gap. Rabbit corneas were exposed ex vivo to 2.5% hydrofluoric acid (HF) solution, and microstructural changes were monitored in the time domain by OCT imaging. HF application and penetration resulted in shrinkage of the corneal thickness, interpreted as a result of osmolar changes and of loss of water-binding capacity, and a substantial increase in OCT signal amplitudes. The effectiveness of different rinsing solutions on the chemical burn was also evaluated. With tap water and with 1% calcium gluconate, the deep corneal stroma remained clear until the end of the rinsing period but became opaque afterwards. With Hexafluorine (R), the cornea remained clear for 60 min after rinsing ceased. We conclude that HR-OCT can assist in the clinical evaluation of an ex vivo eye irritation test, and that decontamination of an HF burn using Hexafluorine (R), is efficient. (c) 2007 Elsevier Ltd and ISBI. All rights reserved.
引用
收藏
页码:549 / 555
页数:7
相关论文
共 50 条
  • [31] Fluorescence diffuse optical tomography by full time-resolved scheme
    Gao, Feng
    Miao, Hui
    Zhao, Huijuan
    Tanikawa, Yukari
    Yamada, Yukio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [32] SIMULATION OF TIME-RESOLVED OPTICAL COMPUTER-TOMOGRAPHY IMAGING
    YAMADA, Y
    HASEGAWA, Y
    MAKI, H
    OPTICAL ENGINEERING, 1993, 32 (03) : 634 - 641
  • [33] Real-time phase-resolved optical coherence tomography and optical Doppler tomography
    Ding, ZH
    Zhao, YH
    Ren, HW
    Nelson, JS
    Chen, ZP
    OPTICS EXPRESS, 2002, 10 (05): : 236 - 245
  • [34] Time-Resolved Ultra-High Resolution Optical Coherence Tomography for Real-Time Monitoring of Selective Retina Therapy
    Steiner, Patrick
    Ebneter, Andreas
    Berger, Lieselotte Erika
    Zinkernagel, Martin
    Povazay, Boris
    Meier, Christoph
    Kowal, Jens H.
    Framme, Carsten
    Brinkmann, Ralf
    Wolf, Sebastian
    Sznitman, Raphael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (11) : 6654 - 6662
  • [35] Improving Localization of Deep Inclusions in Time-Resolved Diffuse Optical Tomography
    Orive-Miguel, David
    Herve, Lionel
    Condat, Laurent
    Mars, Jerome
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [36] A 32-channel time-resolved instrument for medical optical tomography
    Schmidt, FEW
    Fry, ME
    Hillman, EMC
    Hebden, JC
    Delpy, DT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01): : 256 - 265
  • [37] Diffuse optical tomography by using time-resolved single pixel camera
    Farina, A.
    Lepore, M.
    Di Sieno, L.
    Dalla Mora, A.
    Ducros, N.
    Pifferi, A.
    Valentini, G.
    Arridge, S.
    D'Andrea, C.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XI, 2015, 9319
  • [38] Diffuse Optical Tomography using Time-resolved Photon Path Distribution
    Yukio Ueda
    Kazuyoshi Ohta
    Yutaka Yamashita
    Optical Review, 2005, 12 : 334 - 337
  • [39] TIME-RESOLVED DIFFUSE OPTICAL TOMOGRAPHY OF HUMAN FOREARM UNDER EXERCISE
    Endo, Yasuomi
    Tanikawa, Yukari
    Okawa, Shinpei
    Masamoto, Kazuto
    Okada, Hidetaka
    Kizuka, Tomohiro
    Miyakawa, Michio
    Hoshi, Yoko
    Yamada, Yukio
    PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011, VOL 1 PTS A AND B, 2011, : 71 - +
  • [40] Assessment of an in situ temporal calibration method for time-resolved optical tomography
    Hebden, JC
    Gonzalez, FM
    Gibson, A
    Hillman, EMC
    Yusof, RM
    Everdell, N
    Delpy, DT
    Zaccanti, G
    Martelli, F
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (01) : 87 - 92